Ford Ranger EV (2001 year). Manual — part 182
414-03B-124
414-03B-124
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
Flow Through Blower
Removal
1. Remove the traction battery. Refer to
2. Remove the traction battery cover.
1 Remove the 22 bolts.
2 Remove the cover.
3. Remove the blower cover.
1 Remove the four bolts (two each side).
2 Remove the blower cover.
414-03B-125
414-03B-125
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
4. Disconnect the blower electrical connector.
5.
CAUTION: The flow through blower is
very fragile and can easily be damaged if
mishandled.
Remove the flow through blower.
1 Remove the nuts.
2 Remove the blower.
6. Remove the flow through blower bracket.
1 Remove the bolts.
2 Remove the bracket.
Installation
1. To install, reverse the removal procedure.
414-03B-126
414-03B-126
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
Recirculating Blower
Removal
414-03B-127
414-03B-127
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
2. Remove the traction battery cover.
1 Remove the 22 bolts.
2 Remove the cover.
3. Disconnect the recirculating blower electrical
connector and cut the zip tie.
4. Remove the composite bar bolts.
5. Remove the high-voltage harness push pin.