Chery Tiggo 5 (T21). Manual — part 65
06–
102
06
a. Measure the compression of misfiring cylinder (
a. Replace the spark plug with a normally functioning one.
b. Perform spark test.
Connect ignition coil connector.
Connect spark plug and ignition coil, and ground spark plug housing.
Start and run the engine for no more than 2 seconds, and check if spark is generated.
a. Check resistance of primary winding of ignition coil.
b. Check resistance of secondary winding of ignition coil.
5
Check compression of misfiring cylinder
Check engine to confirm cause of low
compression
NG
Check injectors, valve clearance, intake system and fuel pressure, etc. of misfiring cylinder
6
Check spark of misfiring cylinder with a normally functioning spark plug
OK
Replace spark plug
OK
7
Check ignition coil
NG
RT21140070
1 2 3 4
-
+
Multimeter
Connection
Condition
Specification (Ω)
Terminal 1 -
Terminal 3
Normal
temperature
0.50 - 0.64
Terminal 2 -
Terminal 3
Normal
temperature
0.50 - 0.64
2
3
4
1
RT21140080
Multimeter
Connection
Condition
Specification
(kΩ)
Post 1 - Post 4
Normal
temperature
9.5 - 12.1
Post 2 - Post 3
Normal
temperature
9.5 - 12.1
Replace ignition coil
NG
06–
103
06
a. Turn ignition switch to ON.
b. Check voltage between ignition coil connector terminals
and body ground.
a. Turn ignition switch to LOCK.
b. Check fuse EF07 and main relay.
c. Check wire harness between ignition coil connector
terminals and engine compartment fuse and relay box
connector terminals.
Check for Open
Check for Short
8
Check ignition coil power supply voltage
OK
1 2 3 4
E-018
-
+
V
RT21065039
Multimeter
Connection
Condition
Specified
Condition
E-018 (3) - Body
ground
Ignition switch ON
11 to 14 V
Go to step 10
OK
9
Check ignition coil power supply circuit
NG
1 2 3 4
E-018
E-023
C1
C2
C3 C4
C5
C6
C7
C8 C9 C10
-
+
RT21065040
Multimeter
Connection
Condition
Specified
Condition
E-018 (3) - E-023
(C4)
Always
Continuity
Multimeter
Connection
Condition
Specified
Condition
E-018 (3) or
E-023 (C4) - Body
ground
Always
No continuity
E-018 (3) or
E-023 (C4) -
Battery positive
Always
No continuity
06–
104
06
a. Turn ignition switch to LOCK.
b. Disconnect ECM connector E-035.
c. Check wire harness between ignition coil connector
terminals and ECM connector terminals.
Check for Open
Check for Short
a. Use X-431 3G diagnostic tester to read the ECM DTC.
b. Refer to "DTC Confirmation Procedure".
c. Check if DTC P0300-00, P0301-00, P0302-00, P0303-00 or P0304-00 still exists.
Replace wire harness or connector
(ignition coil - engine compartment fuse
and relay box)
NG
10
Check ignition coil control circuit
OK
E-035
37 38 39 40 41 42 43 44 45 46
47
48
25 26 27 28 29 30 31 32 33 34
35
36
13 14 15 16 17 18 19 20 21 22
23
24
1
2
3
4
5
6
7
8
9 10
11
12
1 2 3 4
E-018
-
+
RT21065041
Multimeter
Connection
Condition
Specified
Condition
E-018 (1) - E-035
(36)
Always
Continuity
E-018 (2) - E-035
(35)
Multimeter
Connection
Condition
Specified
Condition
E-018 (1) or
E-035 (36) - Body
ground
Always
No continuity
E-018 (1) or
E-035 (36) -
Battery positive
Always
No continuity
E-018 (2) or
E-035 (35) - Body
ground
Always
No continuity
E-018 (2) or
E-035 (35) -
Battery positive
Always
No continuity
Repair or replace wire harness or
connector (ignition coil - ECM)
NG
11
Check for DTCs
OK
06–
105
06
Replace ECM
NG
System is operating normally.
Reassemble vehicle and perform a road test to confirm that malfunction reported by customer has
been repaired.
OK
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст