Chery Tiggo 5 (T21). Manual — part 361
32–
35
32
g. Turn ignition switch to LOCK, disconnect the negative
battery cable and wait for at least 90 seconds.
h. Using a digital multimeter, check for continuity between
driver seat belt pretensioner connector B-034 and body
ground to check for a short circuit to ground according to
the table below.
Standard Condition
i. Release the activation prevention mechanism built into the
SRS control module assembly connector I-046/B-072.
j. Using a digital multimeter, check for continuity between
the terminals of driver seat belt pretensioner connector
B-034 according to the table below.
Standard Condition
RT21320250
1
2
-
+
B-034
-
+
Multimeter
Connection
Condition
Specified
Condition
B-034 (1) - Body
Always
No continuity
B-034 (2) - Body
ground
Always
No continuity
1
2
-
+
B-034
-
+
RT21320260
Multimeter
Connection
Condition
Specified
Condition
B-034 (1) -
B-034 (2)
Always
No continuity
Replace SRS control module assembly
OK
NG
32–
36
32
a. Turn ignition switch to LOCK, disconnect the negative
battery cable and wait for at least 90 seconds.
b. Disconnect the instrument panel wire harness connector
I-035 and SRS control module assembly connector I-046
(*1).
c. Using a digital multimeter, check for continuity between
the terminals of connector I-035 and connector I-046
according to the table below.
Standard Condition
4
Check driver seat belt pretensioner wire harness and connector (SRS control module
assembly - instrument panel wire harness connector)
-
+
RT21320270
32
31
30
29
28
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
27
26
25
24
23
22
21
20
19
18
17
I-046
18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
I-035
Multimeter
Connection
Condition
Specified
Condition
I-035 (1) -
I-046 (9)
Always
Continuity
I-035 (2) -
I-046 (10)
Always
Continuity
Replace instrument panel wire harness
and connector
NG
OK
32–
37
32
a. Turn ignition switch to LOCK, disconnect the negative
battery cable and wait for at least 90 seconds.
b. Disconnect driver seat belt pretensioner connector B-034
and SRS control module assembly connector
I-046/B-072.
c. Using a digital multimeter, check for continuity between
the terminals of connector B-034 and connector
I-046/B-072 according to the table below.
Standard Condition
5
Check wire harness and connector (SRS control module assembly - driver seat belt
pretensioner)
-
+
RT21320271
32
31
30
29
28
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
27
26
25
24
23
22
21
20
19
18
17
B-072
I-046
1
2
-
+
B-034
Multimeter
Connection
Condition
Specified
Condition
B-034 (1) - I-046/
B-072 (9)
Always
Continuity
B-034 (2) - I-046/
B-072 (10)
Always
Continuity
B-034 (2) - I-046/
B-072 (9)
Always
Continuity
B-034 (1) - I-046/
B-072 (10)
Always
Continuity
B-034 (1) -
B-034 (2)
Always
Continuity
I-046/B-072 (9) -
I-046/B-072 (10)
Always
Continuity
32–
38
32
d. Release the activation prevention mechanism built into
the SRS control module assembly connector
I-046/B-072.
e. Using a digital multimeter, check for continuity between
the terminals of connector B-034 and connector
I-046/B-072 according to the table below.
Standard Condition
-
+
RT21320271
32
31
30
29
28
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
27
26
25
24
23
22
21
20
19
18
17
B-072
I-046
1
2
-
+
B-034
Multimeter
Connection
Condition
Specified
Condition
B-034 (1) - I-046/
B-072 (9)
Always
Continuity
B-034 (2) - I-046/
B-072 (10)
Always
Continuity
B-034 (2) - I-046/
B-072 (9)
Always
No continuity
B-034 (1) - I-046/
B-072 (10)
Always
No continuity
B-034 (1) -
B-034 (2)
Always
No continuity
I-046/B-072 (9) -
I-046/B-072 (10)
Always
No continuity
Replace body wire harness and connector
NG
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.