Chery Tiggo. Manual — part 267
3.
CHECK SHIFT SOLENOID VALVE 6 (SSV6) RESISTANCE
NUMBER
SOLENOID
1
Shift Solenoid Valve 1
2
Shift Solenoid Valve 2
3
Shift Solenoid Valve 3
4
Shift Solenoid Valve 4
5
Shift Solenoid Valve 5
6
Shift Solenoid Valve 6
7
Pressure adjust solenoid
valve
8
Torque converter lock
solenoid valve
9
Manual valve
10
Valve body
• Check SSV6 resistance as shown in the following table:
SHIFT SOLENOID VALVE
A/T ASSEMBLY
TERMINAL
VALVE 1 (SSV1)
B11 - B3
VALVE 2 (SSV2)
B8 - B3
VALVE 3 (SSV3)
B10 - B3
VALVE 4 (SSV4)
B7 - B3
VALVE 5 (SSV5)
B5 - B3
VALVE 6 (SSV6)
B2 - B3
RESISTANCE (23°C)
38 - 42 (
⍀)
Is the check result normal?
Yes
>>
Replace the valve with a known good one.
With X-431, perform the solenoid actuate test.
− If the solenoid can be heard, go to step 6.
− If the solenoid can’t be heard, go to the next step.
No
>>
Replace the damaged solenoid valve.
DIAGNOSIS & TESTING
4.
CHECK SHIFT SOLENOID VALVE 6 (SSV6) POWER SUPPLY
• Turn the ignition switch on.
• Check power supply between SSV6 E-037 terminal
B2 and ground in the A/T assembly connector
E-037.
• Battery voltage should exist.
• Or using the appropriate diagnostic test tool and a digital multimeter perform the following:
• Check the EVS6 solenoid supply voltage between TCM pin 1 and TCM pin 14 when activating the EVS6 sole-
noid and deactivating the EVS6 solenoid.
• Check the shift solenoid control signal. Check the voltage of the shift solenoid in each shift position.
• Check the voltage of the EVS6 solenoid supply circuit between the transaxle assembly electrical connector pin
B3 and pin B2.
SEQUENCE SOLENOID (EVS) CONDITION
LEVER
POSITION
TCM TERMINAL
EVS1
EVS2
EVS3
EVS4
EVS5
EVS6
1 - 10
1 - 9
1 - 7
1 - 8
1 - 13
1 - 14
R
0 V
0 V
0 V
0 V
0 V
0 V
N/P
0 V
0 V
+12 V
0 V
0 V
0 V
1
0 V
0 V
+12 V
+12 V
0 V
0 V
2
0 V
+12 V
0 V
+12 V
0 V
0
3
0 V
0 V
0 V
0 V
0 V
0 V
4
+12 V
+12 V
0 V
0 V
0 V
0 V
Is the check result normal?
Yes
>>
Go to the next step.
No
>>
Repair or replace open circuit or short to ground in harness or connectors.
DIAGNOSIS & TESTING
LTSMD080044
08
5.
CHECK SHIFT SOLENOID VALVE 6 (SSV6) CONTROL CIRCUIT
• Turn the ignition switch off.
• Disconnect TCM connector.
• Disconnect A/T assembly connector.
• Check for harness continuity between the following terminals:
TCM TERMINAL RESISTANCE
A/T ASSEMBLY
CONNECTOR
E-037
TERMINAL
TCM
CONNECTOR
E-036
TERMINAL
CONTINUITY
B2
14
Yes
• Check the harness for short to ground.
Is the check result normal?
Yes
>>
Go to the next step.
No
>>
Repair or replace open circuit or short to ground in harness or connectors.
6.
CHECK DTC
• With the X-431 scan tool, read TCM DTCs.
• Refer to ⬙DTC Confirmation Procedure⬙.
Is DTC P2709 present?
Yes
>>
Replace the TCM.
No
>>
The system is now operating properly.
Reassemble the vehicle and road test to verify the customers complaint is repaired.
DIAGNOSIS & TESTING
P2753 - EPDE Circuit Or Short To Power Supply
P2753 - EPDE Open Circuit Or Short To Ground
DIAGNOSIS & TESTING
LTSMW080014T
08
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.