Chery S11 / Chery QQ. Manual — part 78
Chery QQ Service Manual
found and repaired, then air in
systemis evacuated.
4. Refrigerant circulation is out of condition
Symptom:insufficient cold air
Fault symptom of
refrigeration system
Possible reasons
Fault diagonosis
Troubleshooting
action
Low pressure at both low
pressure side and high side
There is frost between the
reservoir and the assemby
pipe.
Refrigerant can not
flow due to the
reservoir is blocked by
dirt.
Reservoir is
blocked.
replace the
reservoir.
5. Refrigerant doesn’t circulate
Symptom:without cold air (sometimes there has cold air)
151
Chery QQ Service Manual
Fault symptom of
refrigeration
system
Possible reasons
Fault diagonosis
Troubleshooting action
Low pressure side
indicates vacuum and
high pressure side
indicates too low
pressure.
Frost or dew appears
on the pipes before
and behind the
reservoir, drier and
expansion valve.
Refrigerant can not
flow because the water
vapor or dirt block the
refrigeration system
Refrigerant can not
flow because the
thermal sensitive pipe
of the expansion valve
leaks air or is blocked.
Refrigerant
doesn’t circulate
(
1 ) check the thermal
sensitive pipe, expansion
valve and pressure
regulator of the evaporator.
(
2)blow out the dirt in
the expansion valve with
air
(
3)if the dirt can not be
removed, expansion valve
should be replaced.
(
4 ) evacuate air from
system and charge
appropriate amount of new
refrigerant.
If thermal sensitive pipe
leaks air, the expansion
valve should be replaced.
6. Excessive charge of refrigerant or insufficient refrigerating of condensator
symptom:insufficient cold air
152
Chery QQ Service Manual
Fault symptom
of refrigeration
system
Possible reasons
Fault diagonosis Troubleshooting
action
High pressure at both
the low and high
pressure sides even
if the engine runs at
a very low rotation
speed.
Good performance
cannot be played
due to excessive
refrigerant in the
system
Insufficient
refrigerating of
condensator
Excessive refrigerant in
circulation
Excessive charge of
refrigerant
Insufficient refrigerating
of condensator
Radiator rib of
condensator is blocked or
the motor of fan has fault.
(
1)clean the condensator
(
2 ) check the working
conditions of fan’s motor
(
3)if (1)and(2)is normal,
check the amount of
refrigerant and charge
appropriate amount of
refrigerant.
7. Air exists in refrigeration system
Symptom:inadequate
temperature reduction
Note:
when
refrigeration system is open to charge refrigerant without evacuating, the meter will
show reading.
Fault symptom
of refrigeration
system
Possible reasons
Fault diagonosis Troubleshooting
action
153
Chery QQ Service Manual
High pressure at both
the low and high
pressure sides
Low pressure pipe is
too hot to be
touched
Air enters
refrigeration
system
Air exists in the
refrigeration system
↓
Inadequate vacuum
(
1)check if the compressor
oil is polluted or
insufficient.
(
2 ) evacuate air in the
system and charge new
refrigerant.
8. Improper installation of expansion valve /breakdown of the thermal sensitive
pipe(open too much)
。
Symptom:inadequate cold air
Fault symptom of
refrigeration system
Possible reasons
Fault diagonosis
Troubleshooting action
High pressure at both
the low and high
pressure side
Frost or a large amout
of dew at the low
pressure pipe side.
Expansion valve
has fault or
improper
installation of the
thermal sensitive
pipe
Excessive
refrigerant in the
low pressure pipe
↓
Expansion valve
opens too much
(
1)check the installation
status of thermal sensitive
pipe
(
2)if (1)is normal,check
the expansion valve. If it is
broken, replace it.
9. Compression of the compressor is out of condition
Symptom:without cold air
154
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.