"P0269-02","faultpath cylinder3-specific errors -> stop engine- depending on application"
"P0269-08","faultpath cylinder3-specific errors -> stop engine- not-classifyable error"
"P1239-01","faultpath cylinder3-specific warnings - depending on application"
"P123A-02","faultpath cylinder3-specific warnings - depending on application"
"P123B-08","faultpath cylinder3-specific warnings - depending on application"
"P0203-04","faultpath cylinder3-specific warnings - open load "
"P0270-04","faultpath cylinder4-specific errors -> stop engine- short circuit Low Side to High
Side "
"P0271-01","faultpath cylinder4-specific errors -> stop engine- short circuit on Low Side to
battery"
"P0272-02","faultpath cylinder4-specific errors -> stop engine- depending on application"
"P0272-08","faultpath cylinder4-specific errors -> stop engine- not-classifyable error"
"P123C-04","faultpath cylinder4-specific warnings - short circuit Low Side to High Side "
"P123D-01","faultpath cylinder4-specific warnings - short circuit on Low Side to battery"
"P123E-02","faultpath cylinder4-specific warnings - depending on application"
"P0204-08","faultpath cylinder4-specific warnings - not-classifyable error"
"P0273-04","faultpath cylinder5-specific errors -> stop engine- short circuit Low Side to High
Side "
"P0274-01","faultpath cylinder5-specific errors -> stop engine- short circuit on Low Side to
battery"
"P0275-02","faultpath cylinder5-specific errors -> stop engine- depending on application"
"P0275-08","faultpath cylinder5-specific errors -> stop engine- not-classifyable error"
"P123F-01","faultpath cylinder5-specific warnings - depending on application"
"P1240-02","faultpath cylinder5-specific warnings - depending on application"
"P1241-08","faultpath cylinder5-specific warnings - depending on application"
"P0205-04","faultpath cylinder5-specific warnings - open load "
"P0276-04","faultpath cylinder6-specific errors -> stop engine- short circuit Low Side to High
Side "
"P0277-01","faultpath cylinder6-specific errors -> stop engine- short circuit on Low Side to
battery"
"P0278-02","faultpath cylinder6-specific errors -> stop engine- depending on application"
"P0278-08","faultpath cylinder6-specific errors -> stop engine- not-classifyable error"
"P1242-01","faultpath cylinder6-specific warnings - depending on application"
"P1243-02","faultpath cylinder6-specific warnings - depending on application"
"P1244-08","faultpath cylinder6-specific warnings - depending on application"
"P0206-04","faultpath cylinder6-specific warnings - open load "
"P0650-01","Power Stage fault status for MIL- Short Circuit Battery "
"P0650-02","Power Stage fault status for MIL- Short Circuit Ground"

PDF 文件使用 "pdfFactory Pro" 试用版本创建

ÿ

www.fineprint.com.cn

深 圳 市 元 征 科 技 股 份 有 限 公 司

LAUNCH TECH CO., LTD.

深圳市元征软件开发有限公司 LAUNCH SOFTWARE DEVELOPMENT CO.,LTD.

地址:518112 广东省深圳市龙岗区坂雪岗工业区五和大道北元征工业园

ADD:

LAUNCH INDUSTRIAL PARK,NORTH OF WUHE ROAD,BANXUEGABF,LONGGANG DISTRICT, SHENZHEN,P.R,CHINA.

电话

TEL:86-755-84528427 传真 FAX:86-755-84528454

保留一切解释权,处置权,包括复印及传达至第三方。


编写:黄惠生 2008-9-11 15:01 第 80 页 总 274 页

"P0650-04","Power Stage fault status for MIL- No Load "
"P0650-08","Power Stage fault status for MIL- Excess Temperature"
"P0686-01","error path for main relay - main relay does not open in time"
"P0687-02","error path for main relay - main relay opens too early"
"P0251-04","error path of metering unit PWM-powerstage- open load of metering unit output "
"P0252-08","error path of metering unit PWM-powerstage- excess temperature of metering unit
powerstage"
"P0253-02","error path of metering unit PWM-powerstage- short circuit to ground of metering unit
output "
"P0254-01","error path of metering unit PWM-powerstage- short circuit to battery of metering
unit output"
"P025C-02","error path of metering unit AD-channel- signal range check low error of metering
unit AD-channel"
"P025D-01","error path of metering unit AD-channel- signal range check high error of metering
unit AD-channel "
"P060C-08","the fault path contains the supervision of the communication between Watchdog of
CY310 and the controller. The path is used to handle the reversible Shut-down of the system using
the engine coordinator - Set, if error-counter of Watchdog or controller are not plausible or
the system must shut down"
"U1001-01","Error path for BCM in Confirmed Absent state- BCM Confirmed Absent"
"U1002-01","Error path for BSM in Confirmed Absent state- BSM Confirmed Absent"
"U1003-01","error path for bus off state- CAN Confirmed BusOff"
"U0100-01","Error path for ECM in Confirmed mute state- ECM Confirmed Mute"
"U0101-01","Error path for TCM in Confirmed Absent state- TCM Confirmed Absent"
"P0520-04","error path of oil pressure sensor - Hardware signal error "
"P0521-08","error path of oil pressure sensor - Plausibility check - oil pressure too high"
"P0522-02","error path of oil pressure sensor - Voltage below lower limit "
"P0523-01","error path of oil pressure sensor - Voltage above upper limit "
"P0524-08","error path for oil pressure too low error - Plausibility check - oil pressure too
low "
"P0195-04","error path of oil temperature sensor- signal error for CAN"
"P0197-02","error path of oil temperature sensor- Voltage below lower limit "
"P0198-01","error path of oil temperature sensor- Voltage above upper limit "
"P100D-08","error path of oil temperature sensor- Plausibility error between OTS and CTS"
"P1613-01","Fault path for overrun monitoring - Energising time exceeds limit of overrun
monitoring "
"P1614-01","Fault path for redundant engine speed calculation in overrun monitoring -
Plausibility error in engine speed check"

PDF 文件使用 "pdfFactory Pro" 试用版本创建

ÿ

www.fineprint.com.cn

深 圳 市 元 征 科 技 股 份 有 限 公 司

LAUNCH TECH CO., LTD.

深圳市元征软件开发有限公司 LAUNCH SOFTWARE DEVELOPMENT CO.,LTD.

地址:518112 广东省深圳市龙岗区坂雪岗工业区五和大道北元征工业园

ADD:

LAUNCH INDUSTRIAL PARK,NORTH OF WUHE ROAD,BANXUEGABF,LONGGANG DISTRICT, SHENZHEN,P.R,CHINA.

电话

TEL:86-755-84528427 传真 FAX:86-755-84528454

保留一切解释权,处置权,包括复印及传达至第三方。


编写:黄惠生 2008-9-11 15:01 第 81 页 总 274 页

"P0299-01","Permanent governor deviation in PCR - positive governor deviation above limit "
"P0234-02","Permanent governor deviation in PCR - negative governor deviation below limit "
"P0627-04","error path of power stage pre-supply pump - No Load "
"P0628-02","error path of power stage pre-supply pump - Short Circuit Ground"
"P0629-01","error path of power stage pre-supply pump - Short Circuit Battery "
"P062A-08","error path of power stage pre-supply pump - Excess Temperature"
"P0192-02","error path of rail pressure - Voltage below lower limit "
"P0193-01","error path of rail pressure - Voltage above upper limit "
"P0191-01","error path RPS offset monitoring- RPS raw value is above maximum offset "
"P0194-02","error path RPS offset monitoring- RPS raw value is below minimum offset "
"P1011-01","faults for checks in MeUn controlled mode - maximum positive deviation of rail
pressure exceeded"
"P1012-01","faults for checks in MeUn controlled mode - maximum positive deviation of rail
pressure exceeded concerning set flow of fuel"
"P1013-01","faults for checks in MeUn controlled mode - maximum negative rail pressure deviation
with metering unit on lower limit is exceeded"
"P1014-01","faults for checks in MeUn controlled mode - setpoint of metering unit in overrun
mode not plausible "
"P0087-01","rail pressure too Low - minimum rail pressure exceeded"
"P0088-01","rail pressure too high- maximum rail pressure exceeded"
"P1615-08","faultpath for runup test- is set to deaktivate misfire detection during runup test"
"P1616-02","Fault path for test of redundant shut off paths during initialization - Watch dog
switch off path defect"
"P1617-04","Fault path for test of redundant shut off paths during initialization - Voltage
monitoring upper limit shut off path defect "
"P1618-08","Fault path for test of redundant shut off paths during initialization - Voltage
monitoring lower limit shut off path defect "
"P0642-02","sensor supply voltage 1 - Voltage below lower limit "
"P0643-01","sensor supply voltage 1 - Voltage above upper limit "
"P0652-02","sensor supply voltage 2 - Voltage below lower limit "
"P0653-01","sensor supply voltage 2 - Voltage above upper limit "
"P0698-02","ensor supply voltage 3- Voltage below lower limit "
"P0699-01","ensor supply voltage 3- Voltage above upper limit "
"P1641-01","faultpath for shut off test - Indiacate the shut off test is taken by diagnostic
tester "
"P0615-04","Error path starter power stage- No Load "
"P0615-08","Error path starter power stage- Excess Temperature"
"P0616-02","Error path starter power stage- Short Circuit Ground"

PDF 文件使用 "pdfFactory Pro" 试用版本创建

ÿ

www.fineprint.com.cn

深 圳 市 元 征 科 技 股 份 有 限 公 司

LAUNCH TECH CO., LTD.

深圳市元征软件开发有限公司 LAUNCH SOFTWARE DEVELOPMENT CO.,LTD.

地址:518112 广东省深圳市龙岗区坂雪岗工业区五和大道北元征工业园

ADD:

LAUNCH INDUSTRIAL PARK,NORTH OF WUHE ROAD,BANXUEGABF,LONGGANG DISTRICT, SHENZHEN,P.R,CHINA.

电话

TEL:86-755-84528427 传真 FAX:86-755-84528454

保留一切解释权,处置权,包括复印及传达至第三方。


编写:黄惠生 2008-9-11 15:01 第 82 页 总 274 页

"P0617-01","Error path starter power stage- Short Circuit Battery "
"P1619-01","Power Stage fault status for System lamp- Short Circuit Battery "
"P161A-02","Power Stage fault status for System lamp- Short Circuit Ground"
"P161B-04","Power Stage fault status for System lamp- No Load "
"P161C-08","Power Stage fault status for System lamp- Excess Temperature"
"P2533-04","error path for terminal 15 - contains plausibility error [Sig] of T15 - No Terminal
15 signals detected "
"P2141-02","fault path for TVA power stage- Short Circuit Ground"
"P2142-01","fault path for TVA power stage- Short Circuit Battery "
"P0487-04","fault path for TVA power stage- No Load "
"P0488-08","fault path for TVA power stage- Excess Temperature"
"P0638-01","error path of ThrVlv regular mode - maximum failures"
"P1629-01","error path of ThrVlv stateline- maximum failures"
"P0660-04","fault path for VSA power stage- No Load "
"P0661-02","fault path for VSA power stage- Short Circuit Ground"
"P0662-01","fault path for VSA power stage- Short Circuit Battery "
"P1620-08","fault path for VSA power stage- Power stage excess Temperature"
"P0500-04","fault path 1 for vehicle speed sensing- HW signal for vehicle speed not valid "
"P0501-08","fault path 1 for vehicle speed sensing- vehicle speed not plausible with injection
mass and engine speed"
"P0503-01","fault path 1 for vehicle speed sensing- exceeding of the maximum vehicle speed"
"P2158-04","fault path 2 for vehicle speed sensing- CAN signal for vehicle speed not valid"
"P161D-04","Errorpath for dataset variant coding, Npl=Requested variant could not be set,
Sig=variant dataset defect- Signal fault"
"P161E-08","Errorpath for dataset variant coding, Npl=Requested variant could not be set,
Sig=variant dataset defect- Not plausible fault "

3.2 自动变速箱系统

3.2.1 三菱自动变速箱系统

;0xC003
"11","TPS short circuit "
"12","TPS open circuit "
"14","TPS abnormal adjustment "
"15","TFT sensor open circuit "