Автомобили Chery: руководства по ТО — часть 30

深 圳 市 元 征 科 技 股 份 有 限 公 司

LAUNCH TECH CO., LTD.

深圳市元征软件开发有限公司 LAUNCH SOFTWARE DEVELOPMENT CO.,LTD.

地址:518112 广东省深圳市龙岗区坂雪岗工业区五和大道北元征工业园

ADD:

LAUNCH INDUSTRIAL PARK,NORTH OF WUHE ROAD,BANXUEGABF,LONGGANG DISTRICT, SHENZHEN,P.R,CHINA.

电话

TEL:86-755-84528427 传真 FAX:86-755-84528454

保留一切解释权,处置权,包括复印及传达至第三方。


编写:黄惠生 2008-9-11 15:01 第 71 页 总 274 页

"P1100-02","the modify value out of range drift limit - LdlAdjVal below the mimimum drift limit
"
"P2135-08","plausibility check error for accelerate pedal - plausibility with APP violated"
"P062B-01","chip-specific errors- CY33X internal parity error "
"P062B-02","chip-specific errors- CY33X internal program flow error "
"P062B-04","chip-specific errors- CY33X is in Testmode"
"P062B-08","chip-specific errors- CY33X ON timeout for at least 1 cylinder"
"P0607-08","ECU module errors "
"P0645-04","Fault path of air condition power stge- No load "
"P0645-08","Fault path of air condition power stge- Excess Temperature "
"P0646-02","Fault path of air condition power stge- Short Circuit Ground"
"P0647-01","Fault path of air condition power stge- Short Circuit Battery"
"P0532-08","Fault path 1 for air condition pressure - Duty Cycle Max error"
"P0533-04","Fault path 1 for air condition pressure - Duty Cycle Min error"
"P0530-02","Fault path 2 for air condition pressure - PresDSMDeb1Type "
"P2517-02","Fault path for analog air condition pressure- Voltage below lower limit "
"P2518-01","Fault path for analog air condition pressure- Voltage above upper limit "
"P2519-04","Fault path of air condition power stage - CAN Msg. TimeOut error"
"P2519-08","Fault path of air condition power stage - Non-Plausible CAN Msg. Value"
"P1101-01","Intake Air Temperature sensor - Voltage above upper limit "
"P1101-02","Intake Air Temperature sensor - Voltage below lower limit "
"P1102-01","error path for signal range check of duty cycle of air temparature signal - SRC max
error for the duty cycle"
"P1102-02","error path for signal range check of duty cycle of air temparature signal - SRC min
error for the duty cycle"
"P0104-01","error path for plausibility check of offset drift of airmass- airmass ADC raw value
> threshold high"
"P0104-02","error path for plausibility check of offset drift of airmass- airmass ADC raw value
< threshold low "
"P0102-02","fault path for plausibility check of sensitivity drift of airmass - airmass ratio
is lower then threshold low "
"P0103-01","fault path for plausibility check of sensitivity drift of airmass - airmass ratio
is higher then threshold high "
"P0112-02","error path for signal range check of air temparature; do not enter into fault code
memory,always use fault class 0- air temparature below lower Limit "
"P0113-01","error path for signal range check of air temparature; do not enter into fault code
memory,always use fault class 0- air temparature above upper Limit "
"P1562-01","error path for signal range check of battery voltage; do not enter into fault code

PDF 文件使用 "pdfFactory Pro" 试用版本创建

ÿ

www.fineprint.com.cn

深 圳 市 元 征 科 技 股 份 有 限 公 司

LAUNCH TECH CO., LTD.

深圳市元征软件开发有限公司 LAUNCH SOFTWARE DEVELOPMENT CO.,LTD.

地址:518112 广东省深圳市龙岗区坂雪岗工业区五和大道北元征工业园

ADD:

LAUNCH INDUSTRIAL PARK,NORTH OF WUHE ROAD,BANXUEGABF,LONGGANG DISTRICT, SHENZHEN,P.R,CHINA.

电话

TEL:86-755-84528427 传真 FAX:86-755-84528454

保留一切解释权,处置权,包括复印及传达至第三方。


编写:黄惠生 2008-9-11 15:01 第 72 页 总 274 页

memory,always use fault class 0- Voltage above upper Limit "
"P1562-02","error path for signal range check of battery voltage; do not enter into fault code
memory,always use fault class 0- Voltage below lower Limit "
"P0101-01","error path for the raw air mass signal- Signal range check high error "
"P0101-02","error path for the raw air mass signal- Signal range check low error"
"P0100-01","error path for the raw air mass signal- Signal range check high error "
"P0100-02","error path for the raw air mass signal- Signal range check low error"
"P0100-04","error path for the raw air mass signal- signal cutoff or short circuit to either
battery or ground"
"P1106-01","error path for signal range check of reference signal - SRC max error for the time
period "
"P1107-02","error path for signal range check of reference signal - SRC min error for the time
period "
"P0110-04","error path for signal range check of reference signal - signal error for the time
period"
"P0122-02","fault path of Acclerator Pedal 1- Voltage below lower limit "
"P0123-01","fault path of Acclerator Pedal 1- Voltage above upper limit "
"P0222-02","fault path of Acclerator Pedal 2- Voltage below lower limit "
"P0223-01","fault path of Acclerator Pedal 2- Voltage above upper limit "
"P2226-04","error path of atmospheric pressure sensor - CAN signal defect "
"P2228-02","error path of atmospheric pressure sensor - Voltage below lower limit "
"P2229-01","error path of atmospheric pressure sensor - Voltage above upper limit "
"P2299-08","Error path for AccPed and Brake Plausibility- AccPed signal not plausible "
"P0401-02","AirCtl permanent negative governor deviation- negative governor deviation below
limit "
"P0402-01","AirCtl permanent positive governor deviation- Positive governor deviation above
limit "
"P0045-04","fault path for BPA power stage- No Load "
"P0046-08","fault path for BPA power stage- Excess Temperature"
"P0047-02","fault path for BPA power stage- Short Circuit Ground"
"P0048-01","fault path for BPA power stage- Short Circuit Battery "
"P0069-08","Error path for Plausibility Check - Not plausible with atmospheric pressure sensor"
"P0235-04","Error path for Boost pressure sensor- CAN signal defect "
"P0237-02","Error path for Boost pressure sensor- Voltage below lower limit "
"P0238-01","Error path for Boost pressure sensor- Voltage above upper limit "
"P0562-02","battery voltage fault - Voltage below lower limit "
"P0563-01","battery voltage fault - Voltage above upper limit "
"P0571-04","Error path for brake signal - brake signal is defective "

PDF 文件使用 "pdfFactory Pro" 试用版本创建

ÿ

www.fineprint.com.cn

深 圳 市 元 征 科 技 股 份 有 限 公 司

LAUNCH TECH CO., LTD.

深圳市元征软件开发有限公司 LAUNCH SOFTWARE DEVELOPMENT CO.,LTD.

地址:518112 广东省深圳市龙岗区坂雪岗工业区五和大道北元征工业园

ADD:

LAUNCH INDUSTRIAL PARK,NORTH OF WUHE ROAD,BANXUEGABF,LONGGANG DISTRICT, SHENZHEN,P.R,CHINA.

电话

TEL:86-755-84528427 传真 FAX:86-755-84528454

保留一切解释权,处置权,包括复印及传达至第三方。


编写:黄惠生 2008-9-11 15:01 第 73 页 总 274 页

"P0504-08","Error path for brake signal - brake signals not plausible "
"P0594-04","Error Path for Cruise control Lamp powerstage - Short Circuit Battery "
"P0595-02","Error Path for Cruise control Lamp powerstage - Short Circuit Ground"
"P0596-01","Error Path for Cruise control Lamp powerstage - No Load "
"P0115-04","error path of coolant temperature sensor- Can Msg. value defect "
"P0117-02","error path of coolant temperature sensor- Voltage below lower limit "
"P0118-01","error path of coolant temperature sensor- Voltage above upper limit "
"P1103-08","error path of coolant temperature sensor- plausibility defect between OTS and CTS
"
"P1601-01","error path of coolant temperature output- Short circuit to battery"
"P1602-02","error path of coolant temperature output- Short circuit to ground "
"P1603-04","error path of coolant temperature output- No load "
"P1604-08","error path of coolant temperature output- Excess temp."
"P0128-08","Coolant temperature sensor absolute test- Minimum temperature not reached within
time limit "
"P0116-08","Coolant temperature sensor dynamic test - Minimum temperature raise not reached
within time limit "
"P0301-01","error path for Misfire cylinder 1 - number of recognized misfire events above limit
"
"P0302-01","error path for Misfire cylinder 2 - number of recognized misfire events above limit
"
"P0303-01","error path for Misfire cylinder 3 - number of recognized misfire events above limit
"
"P0304-01","error path for Misfire cylinder 4 - number of recognized misfire events above limit
"
"P0305-01","error path for Misfire cylinder 5 - number of recognized misfire events above limit
"
"P0306-01","error path for Misfire cylinder 6 - number of recognized misfire events above limit
"
"P0300-01","error path for misfire in multiple cylinders- number of recognized misfire events
above limit "
"P0856-01","physical plausibility DCS - physical unplausibility of DCS-demand "
"P1109-01","Error path/status for Performance limitation logic- degradation level 0 "
"P110A-02","Error path/status for Performance limitation logic- degradation level 1 "
"P110B-04","Error path/status for Performance limitation logic- degradation level 2 "
"P110C-08","Error path/status for Performance limitation logic- degradation level 3 "
"P161F-01","faultpath for compression test- fault path for compression test "
"P0704-04","diagnostic fault path signals errors of main clutch signal- CAN clutch signal is

PDF 文件使用 "pdfFactory Pro" 试用版本创建

ÿ

www.fineprint.com.cn

深 圳 市 元 征 科 技 股 份 有 限 公 司

LAUNCH TECH CO., LTD.

深圳市元征软件开发有限公司 LAUNCH SOFTWARE DEVELOPMENT CO.,LTD.

地址:518112 广东省深圳市龙岗区坂雪岗工业区五和大道北元征工业园

ADD:

LAUNCH INDUSTRIAL PARK,NORTH OF WUHE ROAD,BANXUEGABF,LONGGANG DISTRICT, SHENZHEN,P.R,CHINA.

电话

TEL:86-755-84528427 传真 FAX:86-755-84528454

保留一切解释权,处置权,包括复印及传达至第三方。


编写:黄惠生 2008-9-11 15:01 第 74 页 总 274 页

not defined"
"P0704-08","diagnostic fault path signals errors of main clutch signal- clutch signal is not
plausible"
"P0575-08","Error path for cruise control plausibility- cruise control raw key status not
plausible "
"P1605-01","Error path for the Tachometer signal- Short Circuit Battery "
"P1606-02","Error path for the Tachometer signal- Short Circuit Ground"
"P1607-04","Error path for the Tachometer signal- No Load "
"P0071-04","error path of environment air temperature sensor- Signal error, only in case of CAN
"
"P0072-02","error path of environment air temperature sensor- Voltage below lower limit "
"P0073-01","error path of environment air temperature sensor- Voltage above upper limit "
"P2530-04","fault path 1 for Engine Compartment Stop Button - Button is Stucked "
"P062F-01","error path for incompatible data value in EEPROM- Error in any element"
"P0489-02","fault path for EGR power stage- Short Circuit Ground"
"P0490-01","fault path for EGR power stage- Short Circuit Battery "
"P0403-08","fault path for EGR power stage- Excess Temperature"
"P0404-04","fault path for EGR power stage- No Load "
"P245A-04","fault path of EGRCD-cooling bypass valve- No Load "
"P245B-08","fault path of EGRCD-cooling bypass valve- Excess Temperature"
"P245C-02","fault path of EGRCD-cooling bypass valve- Short Circuit Ground"
"P245D-01","fault path of EGRCD-cooling bypass valve- Short Circuit Battery "
"P0405-02","error path of exhaust gas recirculator valve position sensor- Voltage below lower
limit "
"P0406-01","error path of exhaust gas recirculator valve position sensor- Voltage above upper
limit "
"P1200-01","Errorpath for filtered energizing time of Cylinder 1- above upper limit of filtered
energizing time "
"P1201-02","Errorpath for filtered energizing time of Cylinder 1- below lower limit of filtered
energizing time "
"P1202-01","Errorpath for filtered energizing time of Cylinder 2- above upper limit of filtered
energizing time "
"P1203-02","Errorpath for filtered energizing time of Cylinder 2- below lower limit of filtered
energizing time "
"P1204-01","Errorpath for filtered energizing time of Cylinder 3- above upper limit of filtered
energizing time "
"P1205-02","Errorpath for filtered energizing time of Cylinder 3- below lower limit of filtered
energizing time "

PDF 文件使用 "pdfFactory Pro" 试用版本创建

ÿ

www.fineprint.com.cn

Была ли эта страница вам полезна?
Да!Нет
1 посетитель считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности