Chery Tiggo T11 LHD. Manual — part 59
Chery T11 Service Manual Electric Injection System
49
Failure Code:
P0352-2
Open circuit of the ignition coil 2-3 cylinder drive circuit or
short circuit to earth
Set emergency control scheme: Switch on the failure lamp till the failure disappears
Stop the fuel injection for 1-4 cylinder
Connection terminal:
MT
20U
Ignition Coil
Normal Measurement Signal
System main power supply:
\
B
12V
1-4 cylinder drive:
32
C
0 to 12 V approx. square
wave signal
Induction peak value > 300 V
2-3 cylinder drive:
52
A
0 to 12 V approx. square
wave signal
Induction peak value > 300
V
Condition for Determination
Possible Reason
Actions
Failure duration > 1.25 s
1) Unreliable connection of
the connecting parts
2) Short
circuit
of
2-3
cylinder drive circuit to the
negative
electrode
of
system power supply
3) Open
circuit
of
2-3
cylinder drive circuit
4) Ignition coil damaged
5) ECM failure
1) Connect again
2) Repair harness
3) Repair harness
4) Replace ignition coil
5) Replace ECM
Chery T11 Service Manual Electric Injection System
50
T11 Canister Control Solenoid Valve
Failure Code:
P0443-
1
Short-circuit between the wire of canister control solenoid
valve and the positive of electrode power supply
Set emergency control scheme: Switch on the failure lamp till the failure disappears
Shut off the canister control solenoid valve
Connection terminal:
MT
20U
Canister Control
Solenoid Valve
Normal Measurement
Signal
System main power supply:
\
B
12V
Solenoid valve drive:
63
A
0 to 12 V square wave
signal
Condition for Determination
Possible Reason
Actions
Failure duration > 2 s
1) Short circuit of solenoid
valve drive circuit to the
positive electrode of power
supply
2) Solenoid valve damaged
3) ECM failure
1) Repair harness
2) Replace
solenoid
valvel
3) Replace ECM
Main Relay
Chery T11 Service Manual Electric Injection System
51
Failure Code:
P0443-2
Open circuit of the wire of canister control solenoid valve or
short circuit to earth
Set emergency control scheme: Switch on the failure lamp till the failure disappears
Shut off the canister control solenoid valve
Connection terminal:
MT
20U
Canister Control
Solenoid Valve
Normal Measurement
Signal
System main power supply:
\
B
12V
Solenoid valve drive:
63
A
0 to 12 V square wave
signal
Condition for Determination
Possible Reason
Actions
Failure duration > 5 s
1) Unreliable connection of the
connecting parts
2) Short circuit of solenoid
valve drive circuit to the
negative electrode of system
power supply
3) Open circuit of solenoid
valve drive circuit
4) Open circuit with system
main
power
supply
connection circuit
5) Solenoid valve damaged
6) ECM failure
1) Connect again
2) Repair harness
3) Repair harness
4) Repair harness
5) Replace
solenoid
valve
6) Replace ECM
Chery T11 Service Manual Electric Injection System
52
Failure Code: P0480-1
Short circuit of radiator low-speed fan relay drive
circuit to the positive electrode of power supply
Set emergency control scheme: Switch on the failure lamp till the failure disappears
NULL
Fan doesn’t operate, till the water temperature increases
to 98℃ and then the high-speed fan activates
Connection terminal:
MT
20U
Low-speed Fan Relay
Normal
Measurement Signal
Battery:
\
Refer to Electrical
System Description
12V
Relay drive:
67
Refer to Electrical
System Description
0V (Operating) and
12V (Stop)
Condition for Determination
Possible Reason
Actions
Failure duration > 3 s
1) Short circuit of relay drive
circuit to the positive electrode
of power supply
2) Relay damaged
3) ECM failure
1) Repair harness
2) Replace relay
3) Replace ECM
Main Power Supply
Dual-speed Fan
High-speed Fan Relay
Low-speed Fan Relay