Jaguar XJ (X350). Manual — part 1208
short to power or open
refer to the new module
installation note at the top of the
DTC Index
B1D2511 Heater Fuel Pump
•
Fuel fired booster heater
module, heater fuel pump
circuit - short to ground
Refer to electrical circuit
diagrams, notes and check fuel
fired booster heater fuel pump
circuit for short to ground
B1D2515 Heater Fuel Pump
•
Fuel fired booster heater
module, fuel pump circuit
- short to power or open
Refer to electrical circuit
diagrams, notes and check fuel
fired booster heater fuel pump
circuit for short to power or open
B1D2611
Combustion Air
Blower
•
Fuel fired booster heater
module, combustion air
fan circuit - short to
ground
Suspect the fuel fired heater
assembly, check and install a new
heater assembly as required,
refer to the new module
installation note at the top of the
DTC Index
B1D2615
Combustion Air
Blower
•
Fuel fired booster heater
module, combustion air
fan circuit - short circuit
to power or open
Suspect the fuel fired heater
assembly, check and install a new
heater assembly as required,
refer to the new module
installation note at the top of the
DTC Index
B1D2692
Combustion Air
Blower
•
Fuel fired booster heater
module, combustion air
fan circuit - performance
or incorrect operation
(fan speed low)
Suspect the fuel fired heater
assembly, check and install a new
heater assembly as required,
refer to the new module
installation note at the top of the
DTC Index
B1D2693
Combustion Air
Blower
•
Fuel fired booster heater
module, combustion air
blower circuit - no
operation
Suspect the fuel fired heater
assembly, check and install a new
heater assembly as required,
refer to the new module
installation note at the top of the
DTC Index
B1D2711
Heater Coolant
Pump
•
Fuel fired booster heater
module, coolant pump
Pin not connected on Jaguar, DTC
will not log on Jaguar
circuit - short to ground
applications
B1D2715
Heater Coolant
Pump
•
Fuel fired booster heater
module, coolant pump
circuit - short to power or
open
Pin not connected on Jaguar, DTC
will not log on Jaguar
applications
B1D2993
No Start, even after
restart attempt
•
Fuel fired booster heater
module - no operation
Suspect the fuel fired heater fuel
supply, check fuel supply pipe's
and joints for security Check fuel
pump for correct operation
B1D3093
No Start In Test
Mode, No
generation of flame
detected in test
mode
•
Fuel fired booster heater
module - no generation of
flame detected in test
mode
Suspect the fuel fired heater fuel
supply, check fuel supply pipe's
and joints for security Check fuel
pump for correct operation
B1D3194
Flame Detected
Prior to Normal
Operation
•
Fuel fired booster heater
module - unexpected
operation
Suspect the fuel fired heater
assembly, check and install a new
heater assembly as required,
refer to the new module
installation note at the top of the
DTC Index
B1D3292
Multiple Flame
Interruption During
Heating Cycle
•
Fuel fired booster heater
module - performance or
incorrect operation
Suspect the fuel fired heater fuel
supply, check fuel supply pipe's
and joints for security Check fuel
pump for correct operation
B1D3392
Flame Interruption
During Normal
Operation
•
Fuel fired booster heater
module - performance or
incorrect operation
Suspect the fuel fired heater fuel
supply, check fuel supply pipe's
and joints for security Check fuel
pump for correct operation
B1D3468
Heater In Lock Out
Mode
•
Fuel fired booster heater
module - event
information
Suspect the fuel fired heater fuel
supply, check fuel supply pipe's
and joints for security Check fuel
pump for correct operation
U007308
Control Module
Communication Bus
"A" Off
•
Fuel fired booster heater
module - CAN bus
signal/message failure
Refer to electrical circuit
diagrams and check fuel fired
booster heater module circuit for
CAN bus circuit fault
www.
U016487
Lost Communication
With HVAC Control
Module
•
Fuel fired booster heater
module - missing message
from climate control
module
Refer to electrical circuit
diagrams and check fuel fired
booster heater module circuit for
CAN bus to climate control
module circuit fault
U030055
Internal Control
Module Software
Incompatibility
•
Fuel fired booster heater
module - not configured
The module can be configured
using the new module
configuration procedure. Check
and configure as required
U1A0008
Private
Communication
Network
•
Fuel fired booster heater
module - Can Bus
signal/message failure
Refer to electrical circuit
diagrams and check fuel fired
booster heater module for W-Bus
communication fault (Telestart
only)
U1A0395
Car Config
Parameter
•
Fuel fired booster heater
module - incorrect
assembly car
configuration code miss-
match (e.g. petrol fuel
burning heater in diesel
vehicle)
The module can be configured
using the new module
procedure. Check and configure
as required
U1A3787
Crash Status
Telegram
•
Fuel fired booster heater
module - missing message
from restraints control
Module
Refer to electrical circuit
diagrams and check fuel fired
booster heater module circuit for
CAN bus to restraints control
Module circuit fault
U1A446C Fuel Level
•
Fuel fired booster heater
module - low fuel
This is not a fault! The vehicle
fuel level was low and the fuel
fired booster heater module shut
down to improve the MPG,
advise vehicle driver that below a
certain fuel level the auxiliary
heater shuts down
Removal and installation
Fuel Fired Booster Heater
Removal
1 . Remove the fender splash shield.
For additional information, refer to Fender Splash Shield (76.10.90)
2 . Disconnect the fuel fired booster heater fuel line.
3 . Remove the fuel fired booster heater retaining bolt.
4 . Raise the vehicle.
5 . Remove the radiator splash shield.
www.