Defender. Manual — part 206
Heating and Ventilation -
Lubricants, Fluids and Sealers
Item
Specification
Sealant — Blower motor to blower motor housing
WSE-M4G323-A4
Torque specifications
Discription
Nm
lb-ft
Blower
15
11
Heater core and evaporator core housing
15
11
Heater control valve nut
6
4
Heater control valve bolt
22
16
Heating and Ventilation - Blower
Removal and Installation
Removal
1. Remove the air inlet duct.
For additional information, refer to:
Air Inlet Duct
(412-01 Air
Distribution and Filtering, Removal and Installation).
2.
CAUTION: Make sure that all openings are sealed. Use
new blanking caps.
Disconnect the coolant expansion tank pipe.
Release the clip.
3. Disconnect the recirculation blend door control cable.
Release the clip.
4. Disconnect the blower motor resistor electrical connector.
5. Disconnect the blower motor electrical connector.
5. Disconnect the blower motor electrical connector.
6. Remove the blower.
Remove the 3 nuts.
Installation
1. To install, reverse the removal procedure.
Tighten to 15 Nm (11 lb.ft).
Name
Silicone Sealant
Heating and Ventilation - Blower Motor
Removal and Installation
Materials
Specification
WSE-M4G323-A4
Removal
• NOTE: LHD shown, RHD similar.
1. Release the coolant expansion tank to radiator pipe.
2. Release the coolant expansion tank.
Remove the bolt.
3. Disconnect the blower motor electrical connector.
4. Remove the blower motor.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.