Iveco Daily. Manual — part 418

198

ELECTRIC/ELECTRONIC SYSTEM

D

AILY

Base - May 2004

The fan is provided with an electromagnetic junction

monitored by the electronic centre pin A39 that activated

the junction remote control switch, to optimise water

cooling.
The electrical fan remote control switch is activated or

deactivated by the centre according to the temperature of:
- the coolant
- over supply air
- the fuel

Engine coolant temperature
Activated at over 96 °C and deactivated at under 84 °C
Over supply air temperature
Activated at over 75 °C and deactivated at under 65 °C
Fuel temperature
Activated at over 20 °C and deactivated at under 10 °C

ELECTROMAGNETIC JUNCTION TECHNICAL VIEW

1. Coil - 2. Connector

Figure 225

88064

ELECTRIC/ELECTRONIC SYSTEM

199

D

AILY

CLIMATE CONTROL
General

The function of the system is to automatically or manually

control the temperature required in the cab.
According to the set required temperature the system

controls:
- automatically:

air vent temperature

fan speed (continuous changing)

- manually:

fan speed

compressor on/off

outside air inlet/re-circulation

MAX DEF function (defrosting);

- totally manually (through bowden cables):

distribution of air flows to the air vents.

AIR FLOW DISTRIBUTION INSIDE THE CAB

Figure 226

000250t

200

ELECTRIC/ELECTRONIC SYSTEM

D

AILY

Base - May 2004

A special electronic control unit controls automatic system

operation checking the various parameters in order to

provide the comfort required in the cab.

The control unit carries out and sets certain functions to

obtain adaptation of the temperature of the cab to the one

required depending on the requests received and the

temperature conditions detected.

CLIMATE CONTROL ELECTRONIC CONTROL UNIT CONNECTIONS

1. Controls on dashboard: inside temperature sensor, re-circulation switch, "eco" switch, fan control potentiometer -

2. Outside temperature sensor - 3. Evaporator sensor - 4. Blown air sensor - 5. Digital display - 6. Fan electronic control

module - 6A. Fan - 7. Compressor - 8. Gear motor for re-circulation function - 9. Air mixing gear motor -

10. Diagnostic connector - 11. EDC-EGR control unit - 12. Climate control electronic control unit

TEMP

kml

9

22

29

35

38

36

30

23

17

10

4

1

3

16

1

3

2

4

11

12

5

10

6A

7

8

9

6

Figure 227

000251t

ELECTRIC/ELECTRONIC SYSTEM

201

D

AILY

DETAIL OF AIR DISTRIBUTION KNOB

VENTILATION AND HEATING CONTROLS ASSEMBLY

1. Temperature adjustment knob - 2. Fan speed control knob - 3. Air distribution knob - 4. Outside air inlet or re-circulation

Air distribution knob
A. Face area vents

B. Face and floor area vents

C. Floor area vents

D. Floor and windscreen area vents

E. Windscreen area vents

A

B

C

D

E

1

2

3

4

Figure 228

Figure 229

000252t