Geely Diagnosis Flow. Manual part — 82
Geely Diagnosis Flow. Manual part - 82
325
Over-high or over-low recharging
voltage from generator
Loosing or over worn-out of generator belt
Replace generator
belt
Loosing or bad contact of fuse of generator
Change fuse
Malfunction of generator regulator
Replace generator
regulator
Malfunction of generator rectifier
Sulfurization or short-circuit of internal battery
plate
Replace generator rectifier or generator
assembly
Replace battery
Normal
Sulfurization
or
short-circuit
Normal
Normal
Normal
Abnormal
Abnormal
Abnormal
Abnormal
326
No. 233 Generator can’t work
Malfunction
Cause
Solution
Malfunction of generator
belt
Check generator belt for tension and wearing condition and if there is 10 mm of
flexibility in the middle of belt under 50 N pressure; if the belt is over-loosing or over
worn-out, the generator belt should be adjusted or replaced;
Malfunction of fuse
Check fuse of generator (60A) for break; if it’s broken, the generator fuse should be
replaced;
Malfunction of generator
regulator
Check if generator regulator is able to adjust generated voltage; if it’s abnormal,
regulator or generator assembly should be replaced;
1. Check forward rectifying: Connect one probe of Ohm meter to positive pole of
rectifying diode, and the other probe to every end of rectifiers; changeover the
polarity of probes and repeat above procedure; the Ohm meter will show
conducting for one and cutoff for the other; if the conductivity is different from above
description, the rectifier or generator assembly should be replaced;
Malfunction of generator
rectifier
2. Check backward rectifying: Connect one probe of Ohm meter to negative pole of
rectifying diode, and the other probe to every end of rectifiers; changeover the
polarity of probes and repeat above procedure; the Ohm meter will show
conducting for one and cutoff for the other; if the conductivity is different from above
description, the rectifier or generator assembly should be replaced.
Malfunction of stator coil of
generator
1. Place multi-meter to Rx1 grade and connect two probes to any two leads of
armature windings; they should be connected; if the resistance is infinite, it
indicates that the break results in failure of generator, thus the coil or generator
assembly should be replaced; 2. Check windings with bond strap: Place
multi-meter to Rx1 grade and connect one probe to any lead of armature winding
and the other probe to core of stator; if the resistance is infinite, the insulation of
armature windings is good, otherwise the coil or generator assembly should be
replaced;
Malfunction of rotator coil
of generator
1. Check resistance of rotator windings: Place multi-meter to Rx1 grade and
connect two slip rings; the standard resistance should be 2.7 – 3.1 Ohm; if the
resistance is different from standard, the rotator or generator assembly should be
replaced; 2. Check flexibility of rotator: The radial swinging standard should be less
than 0.5 mm; if it's abnormal, the generator assembly should be replaced;
Malfunction of internal
brush for engine
The length standard of exposed brush measured by vernier caliper should be 10.5
mm and the minimum length should be 1.5 mm; if the length is smaller than the
minimum length, the brush or generator assembly should be replaced;
Generator can’t
work
Malfunction of harness
Check the harness of generator for short-circuit or poor contact, if it's abnormal, the
generator harness should be checked and repaired;
327
Generator can’t
work
Loosing or over worn-out of generator belt
Adjust or replace generator belt
Broken fuse of generator
Replace fuse
Generator regulator in poor operation
Replace starter
assembly
Open circuit or short-circuit of stator coil of generator
Replace generator
assembly
Damage of internal brush or rotator for generator
Replace generator
assembly
Generator rectifier in poor operation
Replace rectifier or generator
Check and repair
generator loop
Loosing or break of wire for connectors of generator
328
No. 234 Charging indicator of generator is always on or not on
Malfunction Cause
Solution
Malfunction of
generator belt
Check generator belt for tension and wearing condition and if there is 10 mm of flexibility
at middle of belt under 50 N pressure; if the belt is over-loosing or over worn-out, the
generator belt should be adjusted or replaced;
Malfunction of
generator regulator
Check if generator regulator is able to adjust generated voltage; if it’s abnormal,
regulator or generator assembly should be replaced;
1. Check forward rectifying: Connect one probe of Ohm meter to positive pole of
rectifying diode, and the other probe to every end of rectifiers; changeover the polarity of
probes and repeat above procedure; the Ohm meter will show conducting for one and
cutoff for the other; if the conductivity is different from above description, the rectifier or
generator assembly should be replaced.
Malfunction of
generator rectifier
2. Check backward rectifying: Connect one probe of Ohm meter to negative pole of
rectifying diode, and the other probe to every end of rectifiers; changeover the polarity of
probes and repeat above procedure; the Ohm meter will show conducting for one and
cutoff for the other; if the conductivity is different from above description, the rectifier or
generator assembly should be replaced;
Malfunction of
generator fuse
Check positive pole fuse of generator for conducting; if it’s broken, the generator fuse
should be replaced;
Malfunction of
combined instrument
Check indicating diode of combined instrument for mixed connection or breakdown; if
it’s abnormal, the combined instrument should be replaced;
Malfunction of harness Check charging loop for good contact; if it’s abnormal, check or repair the loop;
Charging
indicator of
generator is
always on or not
on
Malfunction of battery Replace battery assembly;
Replace generator
belt
Loosing or over worn-out of generator belt
Check or repair charging indicator
loop of generator
Short-circuit or open circuit of charging indicator loop of
generator
Replace generator
regulator
Generator regulator in poor operation
Change fuse
Broken fuse of generator
Replace rectifier or generator
assembly
Generator rectifier in poor operation
Replace
combined
Short-circuit or open circuit of internal charging indicator of
combined instrument
Charging indicator of generator is always on
or not on
Abnormal
Normal
Normal
Normal
Normal
Normal
Abnormal
Abnormal
Abnormal
Broken
Worn-out
Normal
Normal
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст