Geely Emgrand X7. Manual part — 143
Geely Emgrand X7. Manual part - 143
Installation Procedure:
1. Install upper fixing bolt of
expansion tank assembly.
Torque:10Nm(Metric) 7.4lb-ft(English
system)
2. Install fixing bolt on the right of
expansion reservoir assembly
Torque :25Nm(Metric) 18 .
5lb-ft(English system)
3. Connect coolant hose to
expansion tank.
4. Fill the coolant to the level
between the standard scale lines
of L and F.
5. Install the coolant sealed cap.
NL02-0299b
NL02-0300b
571
2.8.8.3 Replacement of Cooling Fan
Dismantlement Procedure
Do not place hands in between fan blades running area when the fan is not switched off.
1. Disconnect the battery negative
cable. Refer to 2.12.6.1 Battery
Cable Disconnection/Connection
Procedures.
2. Disconnect the fixing clips of the
coolant overflowing hose 2 from
the fan support of the radiator.
NL02-0302b
3. Disconnect the Fan wiring
harness connector.
NL02-0303b
4. Dismantle the fixing bolts at the
right side of the fan cover.
NL02-0304b
572
5. Dismantle the fixing bolts at the
left side of the fan cover.
NL02-0305b
6. Dismantle the fan assembly from
the vehicle.
NL02-0306b
Installation Procedure:
1. Install fan assembly onto the
radiator.
2. Install the fixing bolts at the right
side of the fan cover.
Torque:10Nm(Metric) 7.4lb-ft(English
system)
NL02-0308b
573
3. Install the fixing bolts at the left
side of the fan cover.
Torque:10Nm(Metric) 7.4lb-ft(English
system)
NL02-0309b
4. Connect the cooling fan harness
connector.
5. Connect the battery negative
cable .
6. Fix coolant overflowing hose.
NL02-0302b
574