3.5.7.11 P0712 P0713
1. DTC
description:
DTC P0712
Oil temperature of transmission sensor voltage is low
DTC P0713
Transmission oil temperature sensor high voltage (open circuit)
The Automatic transmission oil temperature sensor is installed in the electromagnetic valve body wire harness.
The sensor of the TFT is a negative coefficient thermal thermostat. When the transmission fluid is at a low
temperature, the sensor resistance is high and will decrease with the temperature rise.
The transmission control unit (TCU) provides a 5V reference signal to the automatic transmission oil temperature
sensor to measure the voltage drop in the circuit. When the oil temperature of the automatic transmission is
increased, the resistance of the sensor is decreased.
2. Conditions for setting DTC and the fault position:
DTC Code DTC detection strategy Conditions for setting the DTC
(Control strategy)
Fault positions
P0712
The transmission oil
temperature sensor
provides a grounding
short circuit indicative
value.
P0713
The transmission oil
temperature sensor
provides an open circuit
indicative value.
Ignition switch is in ON position
1. Electromagnetic
valve and harness
assembly
2. TCU
3.
Automatic
transmission
assembly
3. Circuit
sketch
1295
T
C
U
电磁阀
换挡器
档位开关
LEVER
REVERSE
START
VBS5
VBS6
VBS7
V
BS8
VBS9
VBS1
0
O
n
O
ff
1
O
n
O
ff
2
O
n
O
ff
3
O
n
O
ff
4
EMM
INPUT
SHAFT
SPEE
D
SENSOR
OU
TPUT
SHAFT
t
SPE
ED
SENSOR
25
26
10
11
9
8
13
12
24
23
22
21
20
7
6
5
4
3
2
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
1
18
8
1
3
2
12
14
4
11
12
9
10
15
2
1
4
3
6
5
7
7
J-5
5
16
17
J-5
4
J-5
1
J-5
6
J-5
2
J-5
3
4
11
10
10
15
3
CAN H
启动继电器
倒车信号
输出
主继电器
JF-1
IG2
JB-2
CAN L
10
20
J-3
J-1
J-3
J-2
J-2
J-3
J-3
J-3
J-1
8
J-3
J-3
J-3
J-3
J-3
J-3
J-3
J-3
J-1
J-1
J-1
J-1
J-1
J-1
J-1
J-1
J-1
J-1
J-1
J-1
IF36
NL03-2005c
4. Diagnostic
procedures:
Note: Before carrying out this diagnosis step, observe the data list on fault diagnosis tester and analyze the
accuracy of the data, as these will help with quick diagnosis.
1
Read the fault code again after clearing away the fault code to check if fault codes, except DTC
P0712 and P0713 exist in the control system.
A. Connect fault diagnosis tester to the datalink connector.
B. Rotated ignition switch to ON position
C. Switch on fault diagnostic device power supply
D. Clear DTC code.
E. Reset reading fault code, and check if DTCs meet setting condition of fault code in current
DTC codes shown
Go to step
DTC P0712, P0713
Yes
DTC except for DTC P0712, P0713
No
Gears switch
Main relay
JF-1
Reverse output
signal
Starts relay JB-2
Shifter
Electromagnetic
valve
1296
2
Detect the oil temperature sensor resistor.
A. Turn the ignition switch to the OFF position.
B. Disconnect the harness connector J-4 of the
electromagnetic valve.
C. Measure the resistance between Terminals No.25
and 26 of the electromagnetic valve harness
connector J-4.
电磁阀线束连接器
J-4
1
8
20
14
9
15
10
16
11
17
12
18
13
19
2
21
3
22
4
23
5
24
6
25
7
26
SL03-0036c
Standard resistance value (for detailed parameters, see 3.5.1.3 temperature-resistance relationship of
automatic transmission oil temperature sensor): 20 (
℃
68ºF)56.74 kΩ-65.86kΩ
Does it conform to the standard value?
3
Detect the signal voltage of oil temperature sensor.
A. Turn the ignition switch to the OFF position.
B. Disconnect the harness connector J-4 of the electromagnetic valve.
C. Turn the ignition switch to the ON position.
D. Measure the voltage between Terminals 25 and 26 of the electromagnetic valve harness connector J-4.
Standard voltage: 4.9-5.1V
Does it conform to the standard value?
4
Detect the oil temperature sensor circuit.
No
Yes
Refer to3.4.7.6 fault diagnosis code (DTC) chapter
index
No
Yes
Replace electromagnetic valve assembly
No
Yes
Refer to 3.4.7.8 replacement of automatic
transmission control module to replace TCU.
Electromagnetic valve harness connectorJ-4
1297
A. rotated ignition switch to OFF position.
B. Disconnect the harness connector J-4 of the
electromagnetic valve.
C. Measure the resistance between Terminal No.25
of the electromagnetic valve harness connector
J-4 and terminal No.18 of the automatic control
module J-3.
D. Measure the resistance between Terminal No.26
of the electromagnetic valve harness connector
J-4 and terminal No.8 of the automatic control
module J-3.
E. Turn the ignition switch to the ON position.
F. Measure voltage of electromagnetic valve
harness connector J-4terminalNo.25 and reliable
grounding
自动变速器控制模块线束连接器 J-3
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
SL03-0036c
G. Measure the voltage between terminal No.26 of the electromagnetic valve harness connector J-4 and secure
ground wire.
Results
Test items
Standard value
J-4(25) — J-3(18)
Less than 3 Ω
J-4(26) — J-3(8)
Less than 3 Ω
J-4(25) — Reliable grounding voltage value
O V
J-4(26) — Reliable grounding voltage value
0 V
Does it conform to the standard value?
5 ReplaceTCU
Refer to 3.5.7.8 replace automatic transmission control module
6
Go to automatic transmission fresh process.
Refer to 3.5.7.4 Automatic transmission refresh process
No
Yes
Circuit fault, repair circuit.
Next
Auto-transmissioncontrol module harness
connectorJ-3
1298