Geely Emgrand X7. Manual part — 443
Geely Emgrand X7. Manual part - 443
8.3.8.2 A/C pressure switch replacement
Warning!
See "Warnings for intake of r-134a" in 1.1.1.1 warning and precaution .
1. Disconnect the battery negative cable. Refer to
2.11.8.1 Battery Cable Disconnection/Connection
Procedures.
2. For operation of recycling programs of A/C
refrigerant, refer to 8.2.7.12 Recycling and filling
of A/C refrigerant.
Recycling and filling
3. Disconnect A/C refrigerant pressure switch
harness connector.
4. Dismantle A/C pressure switch.
NL08-0007b
NL08-0008b
Installation Procedure:
1. Install the A/C pressure switch.
NL08-0009b
1771
2. Connect A/C refrigerant pressure switch
harnesses connector.
Notes:
The O-ring related in the process of installation must
be replaced by a new one.
3. A/C
refrigerant
filling
procedures
4. Connect the battery negative cable.
NL08-0010b
1772
8.3.8.3 A/C filter element replacement
Dismantle procedure
Refer to 12.8.3.3 “replacement of glove box of the
instrument panel” to dismantle the glove box of the
instrument panel.
NL08-0011b
2. Dismantle protective cover of A/C filtering
element.
3. Pull out A/C filter element.
NL08-0012b
Installation Procedure:
1. Insert air condition filter element.
NL08-0013b
1773
2. Install A/C filter element trimming cover.
3. Install grove box of instrument desk.
NL08-0014b
1774
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.