Geely Emgrand X7. Manual part — 49

Geely Emgrand X7. Manual part - 49

2.2.7.23 DTC P0135

1. DTC

description:

DTC P0135

Front oxygen sensor heater fails

The pre-catalytic heated oxygen sensor (HO2S) is used for fuel control. The sensor compares the
oxygen content in ambient air and oxygen content in the exhaust flow. Each heated oxygen sensor
has an internal heating element for sensor heating. ECM controls the heated oxygen sensor heating
control circuit. This makes the system enter into the closed-loop control mode earlier, so that ECM
can calculate Air-fuel ratio earlier. ECM controls the heating control circuit switched on or off, so
that heated type oxygen sensor working temperature maintains in the specified range. Engine
control module detects the temperature by Measure the heater current.

Front oxygen sensor heating coil voltage is provided by the main relay controlled by ECM, when
the ignition switch is turned to ON, EM04 sensor harness connector terminal D will have battery
voltage. ECM controls heater working hours through ECM harness connector EM01 terminal
No.14.

2. Conditions For Setting DTC and The Fault Location:

DTC
Code

DTC Detection
Strategy

Conditions For Setting The
DTC (Control Strategy)

Fault Locations

P0135

Hardware Circuit
Inspection

1. Engine Running Longer

than 60 s.

2. At idle Running Condition.

3. Pre-Catalytic

Oxygen

Sensor Heating

4. Pre-Catalytic

Oxygen

Sensor Heating Control
Terminal Disconnected.

5. Duration

Less

Than

20s.

1. Sensor

Circuit

2. Sensor

3. ECM.

3. Circuit

sketch

Refer to 2.2.7.22 DTC P0131 P0132 P0133 P0134.

4. Diagnostic

Steps:

Note: Before carrying out this diagnosis step, observe the data list on fault diagnosis tester and
analyze the accuracy of the data, as these will help with quick diagnosis.

Step 1

Initial Inspection

Inspect the existence of following factors that will affect the heated type oxygen sensor working
status:

(a) Exhaust system leakage or blockage.

(b) Water enters into the heated oxygen sensor connector.

(c) After engine working in high temperature, whether exhaust pipes are too hot or not.

Step 2

Inspect front oxygen sensor heater resistance.

Next

195

(a) Rotated ignition switch to OFF

position .

(b) Disconnect front oxygen sensor

wiring harness connector.

(c)

Measure heater resistance
between front oxygen sensor
terminals C and D.

Standard Resistance

20 (68ºF) 8.1

-11.1Ω

(d) Connect front oxygen sensor

wiring harness connector.

Is resistance the specified value?

前氧传感器线束连接器

EM04

A

B

C

D

NL02-0040c

Step 3

Inspect the terminal No. D to ground voltage.

(a) Rotated ignition switch to OFF position.

(b) Disconnect front oxygen sensor wiring harness connector.

(c) Rotated ignition switch to ON position.

(d) Measure voltage between front oxygen sensor wiring harness connector EM04 terminal D

and a reliable ground.

Standard Voltage: 11-14V

(e) Connect front oxygen sensor harness connector EM04.

Is voltage the specified value?

Step 4

Inspect the front oxygen sensor terminal heating control signal continuity.

No

Front oxygen sensor heater power supply
circuit fault

Yes

No

Replace the front oxygen sensor. Go to
step 11.

Yes

Front oxygen sensor harness

connectorEM04

196

(a) Rotated ignition switch to OFF

position .

(b) Disconnect front oxygen sensor

harness connector EM04.

(c)

Disconnect ECM harness
connector EM01.

(d) Test Continuity between front

oxygen sensor wiring harness
connector EM04 terminal C and
ECM harness connector EM01
terminal No.24.

ECM线束连接器

EM01

1

2

4

5

3

81

63

44

25

6

62

43

24 23 22 21 20 19 18 17 16 15 14 13 12 11 10

9

8

7

26

42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27

45

46

61 60 59 58 57 56 55 54 53 52 51 50 49 48 47

64

65

66

80 79 78 77 76 75 74 73 72 71 70 69 68 67

NL02-0033c

Standard Resistance: Less than 1 Ω

(e) Connect ECM harness connector EM01.

(f) Connect the front oxygen sensor wiring harness connector EM04.

Is resistance the specified value?

Step 5

Inspect ECM working circuit.

(a) Inspect whether ECM power supply circuit is normal.

(b) Inspect whether ECM ground circuit is normal.

Step 6

Replace ECM. Refer to 2.2.8.1 Replacement of Engine Control Module.

(a) Replace

ECM.

(b) Carry out the crankshaft position sensor learning, refer to 2.2.7.11 “Crankshaft Position

Sensor (CKP) Learning.

Step 7

Use fault diagnosis tester to confirm if DTC is stored again .

(a) Connect the fault diagnosis tester to the diagnostic interface.

(b) Turn ignition switch to ON position.

(c) Clear DTC code.

(d) Start and run the engine at idle speed to warm up the engine for at least 5 min.

(e) test the vehicle on the road for at least 5min.

Yes

No

Repair the faulty part.

Yes

No

ECM control circuit malfunction

Yes

ECMharness connectorEM01

197

(f) Read control system DTC code again to confirm that the system has no DTC code.

Step 8

Troubleshooting

5. Maintenance

guide

:

Refer to 2.4.6.2 “Replacement of Front Oxygen Sensor” to replace the front oxygen sensor

No

Refer to 2.2.7.3 Intermittent Fault
Inspection for intermittent fault.

Yes