Geely Emgrand X7. Manual part — 548
Geely Emgrand X7. Manual part - 548
11.5.7.8 Left front door glass lifter do not work (Only for left front door with anti-clamp)
Notes:
Refer to 11.4.7.2 visual Inspection before carrying out the following testing procedures.
NL11-4017b
3 IP47 13 IP47
6 IP47 16 IP47
17 IP47
5 IP47 11 IP47
1 IP47
W/
G
W/
R
W/L
30A
IF
12
20
19
18
IP+B
14 IP50
4 DR02 5
7 DR02
DR02
2
1
DR02
DR02
3 DR02
LF PW
RR GND
RL GND
FR GND
FL GND
RF PW
LR PW
RR PW
LIN
M
DR10
DR10
DR10
BCM
左前门玻璃
升降器开关
DOWN
OT
DN
OT
UP
UP
Diagnostic steps:
1
Inspect the left front window switch.
(a) Operate left front window switch.
(b) Use multimeter to measure switch connection situation.
Test terminal
Test conditions
Conduction condition
DR10(18)—DR10(14)
LF WINDOW UP
Less than 1 Ω
DR10(20)—DR10(14)
LF WINDOW DOWN
Less than 1 Ω
DR10(19)—DR10(14)
LF WINDOW OT DN
Less than 1 Ω
DR10(19)—DR10(14)
LF WINDOW OT UP
Less than 1 Ω
Confirm if the voltage conforms to standard value.
Yes
Go to step 3
No
Left frontdoor
glass lifter switch
2191
2
Replace combination switch ,
(a) Replace combination switch, refer to11.4.8.6 left front glass lifting switch replacement .
(b) Operated Left front window switch.
Confirm whether the left front window works normally.
3
Inspect the left front window anti-trapping control module power supply and the
grounding.
(a) Disconnect left front window anti-clamp module harness connector DR02.
(b) Measure terminal voltage by millimeter.
Test Terminal
Terminal voltage
DR02(2)-grounding 11-14V
DR02(2)-DR02(1) 11-14V
Confirm whether the measures value is normal.
4
Repair and replace the wire harness.
(a) Repair fault points between wire harness connector DR02 terminal No. 2 and fuse, DR02
terminal No. 2 and grounding circuit.
(b) Connect to harness connector DR02.
(c) Operate left front window switch.
Confirm whether the left front window works normally.
5
Inspect the circuit between the left front window anti-trapping control module and the left
front window switch.
Yes
The system is normal.
No
Yes
Go to step 5
No
Yes
The system is normal.
No
2192
(a) Disconnect left front window
switch harness connector.
(b) Disconnect Left front window
anti-clamp control module
harness connector.
(c) Use multimeter to measure
connection sitaution of wire
harness.
NL11-4013b
DR10 左前门玻璃升降器开关线束连接器
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
18
19
20
NL11-4019b
2
1
7
6
5
4
3
DR02 左前门玻璃升降电机线束连接器
3
5
7
Test terminal
Conduction condition
DR10(20)—DR02(7) Less
than
1
Ω
DR10(19)—DR02(5) Less
than
1
Ω
DR10(18)—DR02(3) Less
than
1
Ω
Confirm whether the terminal voltage accords with the standard value?
6
Confirm whether the measures value is normal.
(a) Repair circuit fault points between left front window switch wire harness connector DR10
and left front window anti-clamp control module wire harness connector DR02.
Yes
Go to step 7
No
DR10 left frontdoor glass lifter
switchharness connector
DR02 left front doorglass lifting motor
harness connector
2193
(b) Connect to left front window switch harness connector.
(c) Connect to Left front window anti-clamp control module harness connector.
(d) Operated left front window switch,
Confirm whether the left front window works normally.
7
Inspect the control signal circuit of the fault-side glass lifter motor.
(a) Replace left front window anti-clamp module, refer to11.4.8.5 Left front glass lifter motor
replacement.
Confirm the completion of repair.
8
The system is normal.
11.5.7.9 Left front window anti-clamp function invalidation
Circuit diagram:
See Front Left Door's Anti-jamming Window Does Not Work.
Diagnostic steps:
1
For initialization of the front left window, see 11.4.7.4 Initialization of Window Lifter
(such equipment anti-jamming function).
2
The BCM fault memory DTC code is read by a detector.
3
Repair the window. See11.4.7.7 Only Front Left Window Lifter Does Not Work (without
Anti-jamming Device).
4
The system is normal.
Next
Next
Next
Next
Yes
The system is normal.
No
2194
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.