Geely Emgrand X7. Manual part — 138
Geely Emgrand X7. Manual part - 138
9
Replace cooling fan high-low speed relay 1.
10
Inspect high-speed or low-speed relay 1 coil power supply.
(a) Rotated ignition switch to "OFF" position .
(b) Dismantle the low-speed cooling fan relay 1.
(c) Rotated ignition switch to "ON" position .
(d) Measure voltage between high- or low-speed cooling fan relay 1 terminal No.85 and a
reliable ground.
Standard Voltage: 11-14 V
Confirm whether the voltage conforms to standard value.
11
Inspect high-speed or low-speed relay control circuit.
(a) Rotated ignition switch to "OFF" position .
(b) Disconnect ECM harness connector EM01.
(c) Dismantle the high- or low-speed cooling fan relay.
(d) Test the continuity between the cooling fan high-speed or low-speed relay terminal No.86
and EM01 terminal No.65.
(e) Measure voltage between low speed cooling fan relay terminal No.86 and a reliable ground.
Inspect whether the circuit is short to power supply.
Standard Value
Test Items
Specified Value
High- or Low-speed relay (86)-EM01 (65)
Less than 1 Ω
Resistance Between high- or low-speed Relay
(86) and Reliable Ground
10 kΩ or higher
Confirm whether the measured value conforms to the standard value.
No
Open circuit between high- or low-speed relay 1 terminal
No.85 and fuse EF21,and replace the underhood fuse relay
box if necessary.
Yes
No
Inspect and repair the faulty locations between the
high-speed or low-speed relay 1 terminal No.87 and the
cooling fan wiring harness connector CA09 terminal No.1.
Yes
551
12
Inspect ECM working circuit.
(a) Check if ECM power circuit is normal.
(b) Inspect if ECM ground is normal.
13 Replace
ECM
14 Troubleshooting
Next
No
Repair the faulty part.
Yes
No
Open circuit between high- or low-speed relay terminal
No.86 and EM01 terminal No.65.
Yes
552
2.8.7.6 Cooling Fan 1 Runs At High Speed (Fan 2 Does not Run)
1
Confirm Fault Symptom
2
Use the “Action Test” of fault diagnosis tester to drive the fan low-speed.
Is the High-Speed relay working?
3
Inspect the voltage between the sockets #85 and #86 of the high-speed relay.
(a) Rotated ignition switch to "OFF"
position .
(b) Dismantle high-speed relay.
(c) Rotated ignition switch to "ON"
position .
(d) Connect fault diagnosis tester to
the diagnostic interface.
(e) Select
in
sequence:
Engine/Action Test/Fan High
Speed.
NL11-2262b
ER03
8 5
86
8 7
30
3 0
87
8 6
8 5
ER05
3 0
8 7
86
85
ER06
30
87
87 a
8 6
8 5
ER11
ER08
ER
09
8 5
8 6
87
3 0
4
ER10
2
1
5
3
4
2
1
5
3
4
2
1
5
3
ER04
4
ER02
2
1
5
3
4
2
1
5
3
ER01
ER07
4
2
1
5
3
1
2
3
4
11
12
13
14
15
16
5
6
7
8
9
10
EF0
8
EF0
7
EF2
7
EF2
6
EF2
2
EF2
9
EF
0
3
EF
0
6
EF
0
9
EF2
5
EF1
7
EF1
6
EF1
5
EF
3
5
EF2
1
EF1
4
EF
01
EF
02
EF
04
EF
10
EF
1
1
EF1
8
EF2
4
8 6
8 5
(f) Measure the voltage between the #85 and #86 sockets of the high-speed relay with
multimeter.
(e) Standard Voltage: 11-14 V
Confirm if the voltage conforms to standard value.
4
Repair the underhood Fuse Block Open Circuit fault.
5
Inspect the voltage on the high-speed relay socket #30.
Yes
Replace high-speed relay
No
Yes
Go to step 5
No
No
553
(a) Rotated ignition switch to "OFF" position .
(b) Dismantle high-speed relay.
(c) Measure the effective grounding voltage between the socket #30 of the high-speed relay and
the vehicle body with multimeter.
(e) Standard Voltage: 11-14 V
Confirm if the voltage conforms to standard value.
6
Check the open circuit fault between the high-speed relay terminal #87 and the fan
motor 2.
7 Troubleshooting
Yes
No
Check fuse relay box. If necessary, replace
it.
Yes
554