Geely Emgrand X7. Manual part — 137
Geely Emgrand X7. Manual part - 137
(b) Measure harness connector EM01 terminal No. 17 voltage with a multimeter.
Disconnect ECM harness connector EM01.
(e)Standard Voltage: 11-14 V
Confirm if the voltage conforms to standard value.
4
Inspect ECM working circuit.
(a) Check if ECM power circuit is normal.
(b) Inspect if ECM ground is normal.
5 Troubleshooting
No
Repair the faulty part.
Yes
No
Replace Fan high- or low- speed relay 2 and verify
its high speed running.
Yes
547
2.8.7.5 Cooling fan does not run at low speed
Note: Before carry out this diagnostic procedures, please refer to the2.8.7.2 Cooling Fan Circuit
Diagnosis, which will facilitate the Diagnostic.
1
Inspect cooling fan 1 low speed working power supply.
(a) Rotated ignition switch to "OFF"
position .
(b) Disconnect cooling fan harness
connector CA09.
(c) Rotated ignition switch to "ON"
position .
(d) Connect fault diagnosis tester to
the diagnostic interface.
(e) Select in sequence: Engine /
Action Test /Fan Low-Speed.
(f) Make
low-speed relay work.
NL02-2253b
1
2
CA09 冷却风扇电机1线束连接器
1
(g) Measure the voltage between cooling fan harness connector CA09 terminal No. 1 and a
reliable ground.
Standard Voltage: 11-14 V
Confirm whether the voltage conforms to standard value.
2
Inspect the cooling fan ground circuit.
(a) Rotated ignition switch to "OFF" position .
(b) Disconnect cooling fan harness connector CA10.
(c) Measure cooling fan wire harness connector CA10 terminal 2 plug hole and reliable
grounding.
Resistance value between
Standard Resistance: Less than 1 Ω
Confirm whether the resistance conforms to standard value.
3
Inspect the performance of cooling fan 1 .
No
CA16 terminal No . 3 has poor connection
to ground , Inspect and repair faulty part .
Yes
No
Go to step 6
Yes
CA09cooling fan motor 1harness
connector
548
(a) Rotated ignition switch to "OFF" position .
(b) Connect fault diagnosis tester to diagnosis testing interface.
(c) Rotated ignition switch to "ON" position .
(d) Select in sequence: Engine / Action Test /Fan Low-Speed.
(e) Make low-speed relay 1 work.
(f) Measure the voltage between the cooling fan 1 harness connector CA09 terminal 2 and the
reliable grounding (Note: don’t disconnect the connection between the harness connector
CA09 and Fan 1).
Standard Voltage: 11-14 V
Confirm whether the voltage conforms to standard value.
4
Inspect the power supply for cooling fan 2 .
(a) Rotated ignition switch to "OFF" position .
(b) Disconnect cooling fan harness connector CA10.
(c) Connect fault diagnosis tester to diagnosis testing interface.
(d) Turn ignition switch "ON" position.
(e) Select in sequence: Engine / Action Test /Fan Low-Speed.
(f) Make low-speed relay 1 work.
(g) Measure voltage between CA10 cooling fan harness connector terminal No.1 and a reliable
ground.
Standard Voltage: 11-14 V
Confirm whether the voltage conforms to standard value.
5
Replace the fan 2.
6
Use the “Action Test” of fault diagnosis tester to drive the fan low-speed.
(a) Does the low-speed relay 1 work?
No
Inspect the circuit between Fan 2 and Fan 1 as well
as the low-speed relay 2 and repair the faults found.
Yes
No
Replace the fan 1.
Yes
549
7
Inspect the high-speed and low-speed relay 1 socket No.30 input power supply.
(a) Rotated ignition switch to "OFF"
position .
(b) Dismantle the cooling fan high-
or low-speed relay 1.
(c) Measure voltage between high-
or low-speed cooling fan relay 1
socket No.30 and a reliable
ground.
Standard Voltage: 11-14 V
Confirm whether the voltage
conforms to standard value.
NL11-2257b
ER03
8 5
86
8 7
30
3 0
87
8 6
8 5
ER05
3 0
8 7
86
85
ER06
30
87
87 a
8 6
8 5
ER11
ER08
ER
09
8 5
8 6
87
3 0
4
ER10
2
1
5
3
4
2
1
5
3
4
2
1
5
3
ER04
4
ER02
2
1
5
3
4
2
1
5
3
ER01
ER07
4
2
1
5
3
1
2
3
4
11
12
13
14
15
16
5
6
7
8
9
10
EF0
8
EF0
7
EF2
7
EF2
6
EF2
2
EF2
9
EF
0
3
EF
0
6
EF
0
9
EF2
5
EF1
7
EF1
6
EF1
5
EF
3
5
EF2
1
EF1
4
EF
01
EF
02
EF
04
EF
10
EF
1
1
EF1
8
EF2
4
3 0
8
Inspect high-speed or low-speed cooling fan relay 1 and cooling fan harness connector
CA09 wiring harnesses.
(a) Rotated ignition switch to "OFF" position .
(b) Dismantle the cooling fan high- or low-speed relay 1.
(c) Disconnect cooling fan wiring harness connector CA09.
(d) Test continuity between high-speed or low-speed cooling fan relay 1 terminal No.87 and
cooling fan wiring harness connector CA09 terminal No.1.
(e) Measure resistance between high-speed cooling fan relay 1 terminal No.87 and a reliable
ground. Inspect whether the circuit is short to ground.
Standard Value
Test Items
Specified Value
Cooling Fan High-Speed Relay 1(87)-CA09(1)
Less than 1 Ω
Resistance Between Cooling Fan High-Speed
Relay 1(87) and Reliable Grounding
10 kΩ or higher
Confirm whether the measured value conforms to the standard value.
No
Inspect and repair the faulty locations and replace
the underhood fuse relay box if necessary.
Yes
No
Go to step 10
Yes
550
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст