Geely Emgrand X7. Manual part — 682
Geely Emgrand X7. Manual part - 682
3. Install 4 fixing bolts of horizontal beam and main
host of air conditioner.
Torque: 9Nm (Metric system) 6.7lb-ft (English
system)
NL12-0267b
4. Install 4 fixing bolts between the left side of
horizontal beam and vehicle body.
Torque: 24Nm (Metric) 17. 8lb-ft(English system)
NL12-0266b
5. Install and tighten the left bond strap fixing bolt.
Torque:10Nm(Metric) 7.4lb-ft(English system)
NL12-0265b
2727
6. Install the fixing bolt for the central ground wire.
Torque:10Nm(Metric) 7.4lb-ft(English system)
NL12-0264b
7. Install the right ground wire fixing bolt.
Torque:10Nm(Metric) 7.4lb-ft(English system)
NL12-0263b
8. Connect the harness connector of the blower
motor.
NL12-0269b
2728
9. Conenct the dashboard harness connector and
engine harness connector.
NL12-0261b
10. Connect to airbag module connector.
NL12-0260b
11. Connect auxiliary instrument table parking brake
switch connector and floor wire harness
connector.
NL12-0259b
2729
12. Connect to 2 connector under the BCM
NL12-0270b
13. Connect instrument panel wire harness and 2
wire harness connectors on the top of BCM.
NL12-0271b
14. Connect the brake lamp switch harness
connector.
NL12-0272b
2730