Geely EC718, EC718RV, EC715, EC715RV. Manual part — 332

Geely EC718, EC718RV, EC715, EC715RV. Manual part - 332

FE07-0006b

11. Remove the mechanical steering column assembly

bracket to carrier connecting bolt.

12. Remove the ignition switch cylinder.

FE07-0007b

13. Remove the mechanical steering column assembly

universal joint bolt, disconnect the upper and lower
intermediate shafts from the power steering gear
assembly input shaft.

14. Remove the mechanical steering column assembly with

universal joint .

Installation Procedure:

FE07-0007b

1.

Install the mechanical power steering column with the
upper and lower steering intermediate shaft assembly to
the power steering gear assembly input shaft and tighten
the bolts.

Torque: 28 Nm (Metric) 20.7 lb-ft (US English)

Steering System

Steering Wheel and Steering Column

7-47

FE07-0008b

2.

Install the mechanical steering column assembly bracket
and carrier connecting bolts and tighten.

Torque: 25 Nm (Metric) 18.5 lb-ft (US English)

FE07-0009b

3.

Install the mechanical steering column assembly bracket
retaining bolts.

Torque: 25 Nm (Metric) 26 lb-ft (US English)

4.

Install the ignition switch cylinder.

5.

Install the side and the lower instrument panel shield
panels.

6.

Install the wiper and washer switch.

7.

Install the headlamp switch.

8.

Install the clock spring.

9.

Install the mechanical steering column assembly upper
and lower shield panels.

10. Install the steering wheel.

11. Connect the battery negative cable.

12. Check the airbag warning lamp.

7-48

Steering Wheel and Steering Column

Steering System

8 Heating, Ventilation and A/C System

8.1 Warnings and Notices. . . . . .8-2

8.1.1 Warnings and Notices. . . . . . . . . . ...8-2

8.2 Automatic Air-conditioning. . . ..8-3

8.2.1 Specifications. . . . . . . . . . ...8-3

8.2.1.1 Fastener Tightening Specifications. . . . . 8-3
8.2.1.2 Cooling System Parameters. . . . . . . ...8-3
8.2.1.3 System Capacity. . . . . . . . . . . . 8-4
8.2.1.4 Indoor / Outdoor Temperature Sensor Resistance
Properties. . . . . . . . . . . . . . . . . ...8-5

8.2.2 Description and Operation. . . . . . 8-6

8.2.2.1 Description and Operation. . . . . . . . ..8-6

8.2.3 System Working Principle. . . . . . .8-9

8.2.3.1 Air-conditioning Control Panel Features Description
. . . . . . . . . . . . . . . . . . . . . ...8-9
8.2.3.2 Automatic Air-conditioning Working Principle. ...8-
11

8.2.4 Component Locator. . . . . . . . 8-13

8.2.4.1 Air-conditioning System Component Component
Locator. . . . . . . . . . . . . . . . . . .8-13
8.2.4.2 Air-conditioning Assembly Component Locator. . .8-
14
8.2.4.3 Air-conditioning Panel Diagram. . . . . . 8-15

8.2.5 Disassemble View. . . . . . . . ..8-16

8.2.5.1 Disassemble View. . . . . . . . . . . 8-16

8.2.6 Schematic. . . . . . . . . . . ...8-18

8.2.6.1 Air-conditioning Control System Schematic. .8-18
8.2.6.2 Air-conditioning System Circuit Schematic. ...8-19

8.2.7 Diagnostic Information and Procedures. .8-
21

8.2.7.1 Diagnosis Description. . . . . . . . . ...8-21
8.2.7.2 Visual Inspection. . . . . . . . . . . ..8-21
8.2.7.3 Air-conditioning Control Module Terminal List. ..8-
21
8.2.7.4 Data Stream List. . . . . . . . . . . ...8-23
8.2.7.5 DTC Code Table. . . . . . . . . . . ..8-23
8.2.7.6 Air-conditioning Clutch Inoperative. . . . ...8-24
8.2.7.7 Air-conditioning Blower Inoperative. . . . ..8-31
8.2.7.8 Insufficient Cooling. . . . . . . . . . ...8-35

8.2.7.9 Insufficient Heating. . . . . . . . . . ...8-37
8.2.7.10 Air-conditioning Refrigerant Recovery and Filling.
8-38

8.2.8 Removal and Installation. . . . . . 8-42

8.2.8.1 Air-conditioning Control Panel Replacement. . 8-
42
8.2.8.2 Air-conditioning Pipe Replacement. . . . ..8-44
8.2.8.3 Air-conditioning Pressure Switch Replacement. . .8-
47
8.2.8.4 Air Filter Replacement. . . . . . . . . ..8-48
8.2.8.5 Air-conditioning Assembly Replacement. . ..8-49
8.2.8.6 Expansion Valve Replacement. . . . . . 8-54
8.2.8.7 Air-conditioning Compressor Replacement. ..8-57
8.2.8.8 Blower Speed Control Module Replacement. ...8-
58
8.2.8.9 Blower Motor Replacement. . . . . . . ..8-59
8.2.8.10 Warm and Cold Air Adjust Motor and Inside and
Outside Circulation Motor Replacement. . . . . ...8-60
8.2.8.11 Instrument Panel Air Duct Replacement. . 8-61
8.2.8.12 Air-conditioning Ventilation Pipe Replacement. .8-
63
8.2.8.13 Heater Core Replacement. . . . . . . ..8-63
8.2.8.14 Evaporator Core Replacement. . . . . ...8-64
8.2.8.15 Condenser Replacement. . . . . . . . 8-66
8.2.8.16 Ambient and Sun Light Sensor Replacement. 8-
68
8.2.8.17 Outside Temperature Sensor Replacement. ...8-
68
8.2.8.18 Inside Temperature Sensor Replacement. ..8-69
8.2.8.19 Evaporator Temperature Sensor and Heat Core
Temperature Sensor Replacement. . . . . . . ..8-70

Heating, Ventilation and A/C System

Table of Contents

8-1

8.1 Warnings and Notices

8.1.1 Warnings and Notices

Warning!

Carry out the refrigerant related work in a well-ventilated
environment. Do not breathe refrigerant vapor. To avoid
inhalation of air-conditioning refrigerant R-134a (PTFE
oxide), and lubricant vapor or mist. Contact with them the
will stimulate the eyes, nose and throat. Operate in a
well-ventilated area. When removing R-134a from the
air-conditioning system, use certified maintenance
equipment (R-134a recycling equipment) that meets the
requirements. If the system accidentally discharges,
before continuing to repair, the work area must be
ventilated. Other relevant health and safety information
can be obtained from refrigerant and lubricant
manufacturers.

Warning!

Before servicing the electrical system, disconnect the
battery negative cable. It is prohibited to carry out
welding or steam cleaning operations near the vehicle
with air-conditioning pipelines or parts installed.

Air-conditioning refrigerant Notice

Note

Skin contact may cause frostbite.

Must comply with the instructions provided by the
manufacturer. During operation, wearing proper
goggles and protective gloves.

To avoid following air-conditioning refrigerant operations

Note

Do not store refrigerant under direct sunlight or near
a heat source.

During filling, do not place the refrigerant bottle
upright, keep the valves facing down.

Do not expose the refrigerant bottle to the frost or
snow.

Do not drop the refrigerant bottle.

Do not in any case, directly discharge the refrigerant
to the atmosphere.

Do not be mix refrigerants, such as R134a (PTFE
ethane) and R12 (2 fluoro-2 chlorinated methane).

Frozen Oil Notice

Note

Must use compressor manufacturers recommended
types and grades of lubricant. Do not mix different types
and grades of lubricant, otherwise it will damage the
compressor. Minimize lubricant contact with air, as it is
highly absorbent.

Note

Do not use water, corrosive or flammable and explosive
solvent to clean the air-conditioning system. It is
recommended to use R-141b, heptane and other
cleaning agents.

8-2

Warnings and Notices

Heating, Ventilation and A/C System

Была ли эта страница вам полезна?
Да!Нет
3 посетителя считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности