Lexus ES300 (1997 year). Manual — part 52
AC0BI–01
N20292
AC–92
–
AIR CONDITIONING
PRESSURE SWITCH
1649
1997 LEXUS ES300 (RM511U)
REMOVAL
1.
DISCHARGE REFRIGERANT FROM REFRIGERATION
SYSTEM
HINT:
At the time of installation, please refer to the following item.
Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrig-
erant.
Specified amount: 800
±
50 g (28.22
±
1.76 oz.)
2.
REMOVE PRESSURE SWITCH FROM LIQUID TUBE
Disconnect the connector and remove the pressure switch.
Torque: 10 N·m (100 kgf·cm, 7 ft·lbf)
HINT:
Lock the switch mount on the tube with an open end
wrench, being careful not to deform the tube, and remove
the switch.
At the time of installation, please refer to the following
item.
Lubricate a new O–ring with compressor oil and install the
switch.
AC0BJ–01
–
AIR CONDITIONING
PRESSURE SWITCH
AC–93
1650
1997 LEXUS ES300 (RM511U)
INSTALLATION
Installation is in the reverse order of removal (See page
Z19533
5
4
2
1
3
5
4
3
2
1
AC2T0–01
Z18060
5
3
2
1
2
5
3
1
Z12319
1
4
2
3
1
2
3
4
N02832
1
5
4
3
2
1
3
2
5
4
AC–94
–
AIR CONDITIONING
RELAY
1651
1997 LEXUS ES300 (RM511U)
RELAY
INSPECTION
1.
INSPECT HEATER MAIN RELAY
(Marking: HTR RLY) CONTINUITY
Condition
Tester connection
Specified condition
Constant
2 – 4
1 – 3
Continuity
Apply B+ between
terminals 3 and 5.
1 – 2
Continuity
If continuity is not as specified, replace the relay.
2.
INSPECT MAGNETIC CLUTCH RELAY
(Marking: MG CLT RLY) CONTINUITY
Condition
Tester connection
Specified condition
Constant
1 – 2
Continuity
Apply B+ between
terminals 1 and 2.
3 – 5
Continuity
If continuity is not as specified, replace the relay.
3.
INSPECT No.1 COOLING FAN RELAY
(Marking: FAN RLY NO.1) CONTINUITY
Condition
Tester connection
Specified condition
Constant
1 – 2
3 – 4
Continuity
Apply B+ between
terminals 1 and 2.
3 – 4
No continuity
If continuity is not as specified, replace the relay.
4.
INSPECT No. 2 COOLING FAN RELAY
(Marking: FAN RLY NO.2) CONTINUITY
Condition
Tester connection
Specified condition
Constant
1 – 2
3 – 4
Continuity
Apply B+ between termi-
nals 1 and 2
3 – 5
Continuity
If continuity is not as specified, replace the relay
Z05932
Z06166
5
3
2
1
2
5
3
1
4
4
–
AIR CONDITIONING
RELAY
AC–95
1652
1997 LEXUS ES300 (RM511U)
5.
INSPECT No.3 COOLING FAN RELAY
(Marking: FAN RLY NO.3) CONTINUITY
Condition
Tester connection
Specified condition
Constant
1 – 2
Continuity
Apply B+ between
terminals 1 and 2.
3 – 5
Continuity
If continuity is not as specified, replace the relay.
6.
INSPECT ENGINE MAIN RELAY
(Marking: ENGINE MAIN RLY) CONTINUITY
Condition
Tester connection
Specified condition
Constant
1 – 3
2 – 4
Continuity
Apply B+ between
terminals 1 and 3.
4 – 5
Continuity
If continuity is not as specified, replace the relay.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст