Lexus ES300 (1997 year). Manual — part 30
N20242
Sight Glass
AC2SY–01
I01386
–
AIR CONDITIONING
AIR CONDITIONING SYSTEM
AC–3
1560
1997 LEXUS ES300 (RM511U)
ON–VEHICLE INSPECTION
1.
INSPECT REFRIGERANT VOLUME
Observe the sight glass on the liquid tube.
Test conditions:
Running engine at 1,500 rpm
Blower speed control switch set at ”HI”
A/C switch ON
Temperature control set at ”MAX. COOL”
Fully open doors
Item
Symptom
Amount of refrigerant
Remedy
1
Bubbles present in sight glass
*Insufficient
(1) Check for gas leakage with gas leak de-
tector and repair if necessary
(2) Add refrigerant until bubbles disappear
2
No bubbles present i sight glass
None, sufficient or too much
Refer to item 3 and 4
3
No temperature difference between com-
pressor inlet and outlet
Empty or nearly empty
(1) Check for gas leakage with gas leak de-
tector and repair if necessary
(2) Add refrigerant until bubbles disappear
4
Temperature between compressor inlet and
outlet is noticeably different
Correct or too much
Refer to items 5 and 6
5
Immediately after air conditioning is turned
off, refrigerant in sight glass stays clear
Too much
(1) Discharge refrigerant
(2) Evacuate air and charge proper amount
of new refrigerant
6
When air conditioning is turned off, refriger-
ant foams and then stays clear
Correct
–
HINT:
*: Bubbles in the sight glass with ambient temperatures higher
than usual can be considered normal if cooling is sufficient.
2.
INSPECT REFRIGERANT PRESSURE WITH MAN-
IFOLD GAUGE SET
This is a method in witch the trouble is located by using a man-
ifold gauge set. Read the manifold gauge pressure when the
these conditions are established.
Test conditions:
Temperature at the air inlet with the switch set
at RECIRC is 30 – 35
°
C (86 – 95
°
F)
Engine running at 1,500 rpm
Blower speed control set at ”HI”
Temperature control set at ”MAX COOL”
(1)
Normally functioning refrigeration system
Gauge reading:
Low pressure side: 0.15 – 0.25 MPa (1.5 – 2.5 kgf/cm
2
)
High pressure side: 0.15 – 0.25 MPa (1.5 – 2.5 kgf/cm
2
)
I01387
Condition : Periodically cools and then fails to cool
I01388
Condition: Insufficient cooling
AC–4
–
AIR CONDITIONING
AIR CONDITIONING SYSTEM
1561
1997 LEXUS ES300 (RM511U)
(2)
Moisture present in refrigeration system.
Symptom seen in
refrigeration system
Probable cause
Diagnosis
Remedy
During operation, pressure on low
pressure side sometimes become
a vacuum and sometime normal
Moisture entered in refrigeration
system freezes at expansion valve
orifice and temporarily stops cycle,
but normal state is restored after a
time when the ice melts
Drier in oversaturated state
Moisture in refrigeration system
freezes at expansion valve orifice
and blocks circulation of refriger-
ant
(1) Replace receiver
(2) Remove moisture in cycle
through repeatedly evacuating air
(3) Charge proper amount of new
refrigerant
(3)
Insufficient cooling
Symptom seen in
refrigeration system
Probable cause
Diagnosis
Remedy
Pressure low on both low and
high pressure sides
Bubbles seen in sight glass con-
tinuously
Insufficient cooling performance
Gas leakage at some place in re-
frigeration system
Insufficient refrigerant in sys-
tem
Refrigerant leaking
(1) Check for gas leakage with gas
leak detector and repair if neces-
sary
(2) Charge proper amount of re-
frigerant
(3) If indicated pressure value is
near 0 when connected to gauge,
create the vacuum after inspecting
and repairing the location of the
leak
I01389
Condition: Insufficient cooling
I01449
Condition: Does not cool (Cools from time to time in some cases)
–
AIR CONDITIONING
AIR CONDITIONING SYSTEM
AC–5
1562
1997 LEXUS ES300 (RM511U)
(4)
Poor circulation of refrigerant
Symptom seen in
refrigeration system
Probable cause
Diagnosis
Remedy
Pressure low in both low and
high pressure sides
Frost on tube from receiver to
unit
Refrigerant flow obstructed by dirt
in receiver
Receiver clogged
Replace receiver
(5)
Refrigerant does not circulate
Symptom seen in
refrigeration system
Probable cause
Diagnosis
Remedy
Vacuum indicated on low pres-
sure side, very low pressure indi-
cated on high pressure side
Frost or dew seen on piping be-
fore and after receiver/ drier or ex-
pansion valve
Refrigerant flow obstructed by
moisture or dirt in refrigeration sys-
tem
Refrigerant flow obstructed by
gas leakage from expansion valve
Refrigerant does not circulate
(1) Check expansion valve
(2) Clean out dirt in expansion
valve by blowing with air
(3) Replace receiver
(4) Evacuate air and charge new
refrigerant to proper amount
(5) For gas leakage from expan-
sion valve, replace expansion
valve
I01390
Condition: Insufficient cooling
I01392
Condition: Insufficient cooling
NOTE : These gauge indica-
tions are shown when the
refrigeration system has
been opened and the refrig-
erant charged without vacu-
um purging.
AC–6
–
AIR CONDITIONING
AIR CONDITIONING SYSTEM
1563
1997 LEXUS ES300 (RM511U)
(6)
Refrigerant overcharged or insufficient cooling of
condenser
Symptom seen in
refrigeration system
Probable cause
Diagnosis
Remedy
Pressure too high on both low
and high pressure sides
No air bubbles seen through the
sight glass even when the engine
rpm is lowered
Unable to develop sufficient per-
formance due to excessive refrig-
eration system
Insufficient cooling of condenser
Excessive refrigerant in
cycle
→
refrigerant over charged
Condenser cooling
→
condenser
fins clogged of condenser fan
faulty
(1) Clean condenser
(2) Check condenser fan motor
operation
(3) If (1) and (2) are in normal
state, check amount of refrigerant
Charge proper amount of refriger-
ant
(7)
Air present in refrigeration system
Symptom seen in
refrigeration system
Probable cause
Diagnosis
Remedy
Pressure too high on both low
and high pressure sides
The low pressure piping hot to
touch
Bubbles seen in sight glass
Air entered in refrigeration system
Air present in refrigeration sys-
tem
Insufficient vacuum purging
(1) Check compressor oil to see if
it is dirty or insufficient
(2) Evacuate air and charge new
refrigerant