Mazda 6. Manual — part 181
CHARGING SYSTEM
G–7
G
GENERATOR INSPECTION
A6E471018300W02
Generator Warning Light
1. Verify that the battery is fully charged.
• Charge if necessary.
2. Verify that the drive belt deflection/tension is correct. (See
• If not as specified, replace the drive belt.
3. Turn the ignition switch to ON and verify that the generator warning light illuminates.
• If not as specified, inspect the generator warning light.
4. Verify that the generator warning light turns off after the engine is started.
• If not specifed, inspect if any of the DTCs are displayed: P0112, P0113, P2502, P2503, P2504.
Generator
Voltage
1. Verify that the battery is fully charged.
2. Verify that the drive belt deflection/tension is correct. (See
• If not as specified, replace the drive belt.
3. Turn off all electrical loads.
4. Turn the engine switch to start the engine and verify that the generator rotates smoothly without any noise while
the engine is running.
5. Measure the voltage at the terminals shown in the table.
• If not as specified, repair or replace the
generator as necessary.
Standard voltage
*
: Turn the following electrical loads on and verify that
the voltage reading increases.
— Headlights
— Blower motor
— Rear window defroster
Current
1. Verify that the battery is fully charged.
• If the battery is not fully charged, charge the battery.
2. Verify that the drive belt deflection/tension is correct. (See
• If not as specified, replace the drive belt.
3. Disconnect the negative battery cable.
4. Connect an ammeter, capable of reading 120 A or above, between generator terminal B and the wiring
harness.
5. Connect the negative battery cable.
6. Turn off all electrical loards.
7. Start the engine and increase the engine speed to 2,000—2,500 rpm.
8. Turn the following electrical loads on and verify that the current reading increases.
• Headlights
• Blower motor
• Rear window defroster
— If generator terminal B current will not increase, repair or replace the generator as necessary.
Note
• Current required for generating power varies with electrical loads applied.
Terminal Ignition switch ON (V)
Idle (V)
[20
°C {68 °F}]
B
B+
13—15
P
Approx. 1
Approx. 3—8
D
Approx. 0
*
A6E4710W003
CHARGING SYSTEM , IGNITION SYSTEM
G–8
Standard current (Reference)
Measuring conditions
Room temperature: 20
°C {68 °F}
Voltage: 13.5 V
Engine hot
*
: Must not be 0 A
End Of Sie
IGNITION COIL REMOVAL/INSTALLATION
A6E471218110W01
1. Disconnect the negative battery cable.
2. Remove the plug hole plate.
End Of Sie
Engine
speed
(rpm)
Terminal B current (A)
L8
LF
L3
1,000
0*—80
2,000
0*—90
IGNITION SYSTEM
A6E4712W012
1
Connect
2
High-tension lead (See
)
3
Ignition coil
IGNITION SYSTEM
G–9
G
IGNITION COIL INSPECTION
Primary Coil Winding
1. Remove the ignition coil.
2. Measure the resistance between the following lead holes using an ohmmeter.
• A and B, B and C
— If not specified, replace the ignition coil.
Specification
0.49—0.57 ohms [20
°C {68°F}]
Secondary Coil Winding
1. Remove the ignition coil.
• 1 and 4
• 2 and 3
— If not specified, replace the ignition coil.
Specification
9.5—11.1kilohms
A6E4712W003
A6E4712W001
G–10
IGNITION SYSTEM
Insulation Resistance of Case
1. Disconnect the high-tension lead.
2. Disconnect the ignition coil connector.
3. Measure the insulation resistance between the following terminals and ignition coil case using an ohmmeter.
• Terminal B and ignition coil case.
— If not specified, replace the ignition coil.
Specification
Above 10 Megohm
End Of Sie
SPARK PLUG REMOVAL/INSTALLATION
A6E471218110W03
1. Disconnect the negative battery cable.
2. Remove the plug hoie plate.
• Lift off and remove the plug hole plate from
the installation areas (rubber and clips) as
shown in the figure.
3. Disconnect the high-tension lead.
4. Remove the spark plugs using the plug-wrench.
5. Install the spark plugs using a plug-wrench.
Tightening torque:
10—24 N·m {1.1—2.4kgf·m, 8—17ft·lbf}
End Of Sie
A6E4712W002
A6E4712W201
A6E4712W202