Mazda CX 7. Manual — part 298
CONTROL SYSTEM
07-40–17
07-40
Term
inal
Signal
name
Connected to
Measurement
condition
Voltage (V)
Inspection item (s)
A
Illumination
control
Instrument cluster
Headlight switch ON
and panel light control
switch at max
0.45
• Wiring harness: continuity (Climate
control unit— instrument cluster: A—
2H) (Instrument cluster— body ground:
2A— GND)
• Instrument cluster
Headlight switch ON
and panel light control
switch at min
9.96
• Wiring harness: short circuit (Climate
control unit— instrument cluster: A—
2H)
B
TNS signal
TNS relay
Headlight switch OFF
1.0 or less
• Wiring harness: short circuit (Climate
control unit— TNS relay: B— C)
• TNS relay
• Headlight switch
Headlight switch ON
B+
• Wiring harness: continuity, short circuit
(Climate control unit— TNS relay: B—
C)
• TNS relay
• Headlight switch
C
— —
— —
—
D
— —
— —
—
E
+5V
Airflow mode
actuator
IG SW ON
4.91
• Wiring harness: short circuit (Climate
control unit—airflow mode actuator: E—
B)
• Airflow mode actuator
• Climate control unit: terminal voltage (R,
L)
IG SW OFF
1.0 or less
• Climate control unit replacement
F
FAN ON/
OFF
Airflow volume
control dial
Airflow volume control
dial ON
0.06
• Wiring harness: (Climate control unit—
airflow volume control dial: F— C)
• Airflow volume control dial
Airflow volume control
dial OFF
12.18
• Wiring harness: continuity (Climate
control unit— airflow volume control
dial: F— C)
• Climate control unit: terminal voltage
(R)
• Airflow volume control dial
G
Potentiomet
er input
Airflow mode
actuator
VENT
4.20
• Wiring harness: continuity, short circuit
(Climate control unit— airflow mode
actuator: G— C)
• Airflow mode actuator
• Climate control unit: terminal voltage (E)
BILEVEL
3.34
HEAT
2.44
HEAT/DEF
1.56
DEFROSTER
0.68
H
Rear
window
defroster
switch
Rear window
defroster relay
Rear window defroster
switch OFF
B+
• Wiring harness: continuity, short circuit
(Climate control unit— rear window
defroster relay: H— E)
• Rear window defroster relay
Rear window defroster
switch ON
0.06
• Climate control unit: terminal voltage (L,
R)
• Climate control unit:
I
Evaporator
temperature
sensor input
Evaporator
temperature sensor
Compared with
temperature detected
by evaporator
temperature sensor
Refer to
graph 2
• Wiring harness: continuity (Climate
control unit—evaporator temperature
sensor: I—B, K—A)
• Wiring harness: short circuit (Climate
control unit—evaporator temperature
sensor: I—B)
• Evaporator temperature sensor
• Climate control unit: terminal voltage (L,
R)
J
A/C
BCM
A/C switch ON, airflow
volume control dial at
1st
0.03
• Wiring harness: continuity (Climate
control unit— BCM: J— 3V)
• BCM
A/C switch OFF
5.02
• Wiring harness: continuity, short circuit
(Climate control unit— BCM: J— 3V)
1871-1U-06B(07-40).fm 17 ページ 2006年3月16日 木曜日 午後4時1分
CONTROL SYSTEM
07-40–18
K
Sensor GND
• Evaporator
temperature
sensor
• Ambient
temperature
sensor
• Airflow mode
actuator
Under any condition
1.0 or less
• Climate control unit: terminal voltage (L)
L
GND
Body ground
Under any condition
1.0 or less
• Wiring harness: continuity (Climate
control unit— GND: L— GND)
M
— —
— —
—
N
— —
— —
—
O
— —
— —
—
P
B+
ROOM 15 A fuse
Under any condition
B+
• Wiring harness: continuity, short circuit
(Climate control unit— fuse: P—
ROOM 15 A)
• ROOM 15 A fuse
Q
Motor
operation
Airflow mode
actuator
Moving towards
DEFROSTER
10.60
• Wiring harness: continuity, short circuit
(Climate control unit— airflow mode
actuator: Q— F, S— D)
• Airflow mode actuator
Moving towards VENT
0.69
R
IG2
A/C 10 A fuse
IG SW ON
B+
• Wiring harness: continuity, short circuit
(Climate control unit— fuse: R— A/C
10 A)
• A/C 10 A fuse
IG SW OFF
1.0 or less
• Wiring harness: continuity, short circuit
(Climate control unit— fuse: R— A/C
10 A)
S
Motor
operation
Airflow mode
actuator
Moving towards VENT
10.64
• Wiring harness: continuity, short circuit
(Climate control unit— airflow mode
actuator: S— D, Q— F)
• Airflow mode actuator
Moving towards
DEFROSTER
0.68
T
— —
— —
—
U
— —
— —
—
V
Motor
operation
Air intake actuator
Moving towards
RECIRCULATE
10.62
• Wiring harness: continuity, short circuit
(Climate control unit— air intake
actuator: V— F, X— D)
• Air intake actuator
Moving towards
FRESH
0.66
W
Ambient
temperature
sensor input
Ambient
temperature sensor
Compared with
temperature detected
by ambient
temperature sensor
Refer to
graph 1
• Wiring harness: continuity (Climate
control unit—ambient temperature
sensor: W—B, K—A)
• Wiring harness: short circuit (Climate
control unit—ambient temperature
sensor: W—B)
• Ambient temperature sensor
• Climate control unit: terminal voltage (L,
R)
X
Motor
operation
Air intake actuator
Moving towards
FRESH
10.64
• Wiring harness: continuity, short circuit
(Climate control unit— air intake
actuator: X— D, V— F)
• Air intake actuator
Moving towards
RECIRCULATE
0.67
Term
inal
Signal
name
Connected to
Measurement
condition
Voltage (V)
Inspection item (s)
1871-1U-06B(07-40).fm 18 ページ 2006年3月16日 木曜日 午後4時1分
CONTROL SYSTEM
07-40–19
07-40
End Of Sie
WM: AIR MIX ACTUATOR
AIR MIX ACTUATOR REMOVAL/INSTALLATION
id074000802400
1. Disconnect the negative battery cable.
2. Remove the following parts:
(1) Console panel (See 09-17-15 CONSOLE PANEL REMOVAL/INSTALLATION.)
(2) Console (See 09-17-13 CONSOLE REMOVAL/INSTALLATION.)
(3) Front scuff plate inner (See 09-17-19 FRONT SCUFF PLATE REMOVAL/INSTALLATION.)
(4) Front side trim (See 09-17-18 FRONT SIDE TRIM REMOVAL/INSTALLATION.)
(5) Dashboard under cover
(6) Glove compartment (See 09-17-8 GLOVE COMPARTMENT REMOVAL/INSTALLATION.)
(7) Hood release lever (See 09-14-25 HOOD LATCH AND RELEASE LEVER REMOVAL/INSTALLATION.)
(8) Lower panel (See 09-17-9 LOWER PANEL REMOVAL/INSTALLATION.)
(9) Center panel (See 09-17-8 CENTER PANEL REMOVAL/INSTALLATION.)
(10)Audio unit (See 09-20-4 AUDIO UNIT REMOVAL/INSTALLATION.)
(11)Climate control unit (See 07-40-25 CLIMATE CONTROL UNIT REMOVAL/INSTALLATION [FULL-AUTO
AIR CONDITIONER].) (See 07-40-25 CLIMATE CONTROL UNIT REMOVAL [MANUAL AIR
CONDITIONER].) (See 07-40-26 CLIMATE CONTROL UNIT INSTALLATION [MANUAL AIR
CONDITIONER].)
(12)Knee bolster (See 09-17-12 KNEE BOLSTER REMOVAL/INSTALLATION.)
(13)Meter hood (See 09-17-10 METER HOOD REMOVAL/INSTALLATION.)
(14)Column cover (See 09-17-8 COLUMN COVER REMOVAL/INSTALLATION.)
(15)Instrument cluster (See 09-22-2 INSTRUMENT CLUSTER REMOVAL/INSTALLATION.)
(16)Driver-side air bag module (See 08-10-6 DRIVER-SIDE AIR BAG MODULE REMOVAL/INSTALLATION.)
(17)Steering wheel (See 06-14-6 STEERING WHEEL AND COLUMN REMOVAL/INSTALLATION.)
(18)Combination switch (See 09-18-13 COMBINATION SWITCH REMOVAL/INSTALLATION.)
(19)Steering shaft (See 06-14-6 STEERING WHEEL AND COLUMN REMOVAL/INSTALLATION.)
(20)A-pillar lower trim (See 09-17-16 A-PILLAR LOWER TRIM REMOVAL/INSTALLATION.)
(21)A-pillar trim (See 09-17-15 A-PILLAR TRIM REMOVAL/INSTALLATION.)
(22)Dashboard (See 09-17-4 DASHBOARD REMOVAL/INSTALLATION.)
3. Remove the blower motor. (See 07-40-8 BLOWER MOTOR REMOVAL/INSTALLATION.)
4. Remove the power MOS FET (Full-auto air conditioner) or resistor. (Manual air conditioner) (See 07-40-4
POWER METAL OXIDE SEMICONDUCTOR FIELD EFFECT TRANSISTOR (POWER MOS FET) REMOVAL/
INSTALLATION.) (See 07-40-7 RESISTOR REMOVAL/INSTALLATION.)
5. Remove the blower unit installation nuts.
6. Remove the screw securing the duct (2) to the A/C unit, by inserting a phillips screwdriver into the hole made
after removing the blower motor.
7. Remove the screw securing the duct (2) to the A/C unit.
-20
0
1
2
3
4
5
{-4}
{14}
{32}
{50}
{68}
{86} {104} {122}
-10
TEMPERATURE
V
O
LT
A
GE(V)
0
20
10
30
40
50
{ F}
C
Graph 1 (Ambient temperature sensor)
-20
0
1
2
3
4
5
{-4}
{14}
{32}
{50}
{68}
{86} {104} {122}
-10
TEMPERATURE
V
O
LT
A
GE(V)
0
20
10
30
40
50
{ F}
C
Graph 2 (Evaporetor temperature sensor)
1871-1U-06B(07-40).fm 19 ページ 2006年3月16日 木曜日 午後4時1分
CONTROL SYSTEM
07-40–20
8. Remove the duct (2).
9. Remove in the order indicated in the table.
10. Install in the duct (2).
11. Install the two outer screws, securing the duct (2)
to the A/C unit.
12. Install the screw on the end of the phillips
screwdriver with the packing tape.
Caution
• If the packing tape remains in the duct
(2), it may become a source of noise.
Wind up the packing tape to prevent
pinching when tightening the screw.
13. Install the duct (2) to the A/C unit by inserting a
phillips screwdriver, with the screw, into the hole
made after removing the blower motor.
14. Pull out the Phillips screwdriver together with the
packing tape.
15. Install in the reverse order of removal.
End Of Sie
1
Air mix actuator connector
2
Air mix actuator
INSTALLATION
HOLE OF THE
BLOWER MOTOR
DUCT (2)
SCREW
SCREW
SCREW
acxuuw00000738
1
2
acxuuw00000739
PACKING TAPE
PHILLIPS
SCREWDRIVER
SCREW
acxuuw00000740
1871-1U-06B(07-40).fm 20 ページ 2006年3月16日 木曜日 午後4時1分
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст