Mazda CX-9 Grand Touring. Manual — part 288
DIAGNOSTIC PROCEDURE
DTC P0625 (MZI-3.7) DIAGNOSTIC PROCEDURE
STEP
INSPECTION
ACTION
1
VERIFY FREEZE FRAME DATA HAS
BEEN RECORDED
Has FREEZE FRAME DATA been
Yes Go to the next step.
No
Record FREEZE FRAME DATA on the repair
2008 Mazda CX-9 Grand Touring
2008 ENGINE PERFORMANCE On-Board Diagnostic (MZI-3.7) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:08:40 AM
Page 285
© 2005 Mitchell Repair Information Company, LLC.
recorded?
order, then go to the next step.
2
VERIFY RELATED REPAIR
INFORMATION AVAILABILITY
Verify related Service Bulletins and/or
on-line repair information availability.
Is any related Service Bulletins
available?
Yes
Perform repair or diagnosis according to the
available Service Bulletins.
If the vehicle is not repaired, go to the
next step.
No
Go to the next step.
3
INSPECT DRIVE BELT DAMAGED
Verify inspect the drive belt for
damage.
Is the drive belt normal?
Yes Go to the next step.
No
Replace the drive belt, then go to Step 10. (See
DRIVE BELT INSPECTION [MZI-3.7] .)
4
INSPECT GENERATOR TERMINAL
FOR POOR INSTALLATION
Turn the engine switch off.
Inspect generator terminal B for
looseness.
Are there any malfunction?
Yes
Connect generator terminal B correctly, then go
to Step 10.
No
Go to the next step.
5
INSPECT GENERATOR CIRCUIT FOR
SHORT TO GROUND
Inspect for continuity between the
following terminal:
Generator terminal RC (wiring
harness-side) and body ground.
Generator terminal LI (wiring
harness-side) and body ground.
Are there continuity?
Yes
Repair or replace suspected part, then go to
Step 10.
No
Go to the next step.
6
INSPECT BATTERY POSITIVE
TERMINAL FOR POOR
INSTALLATION
Turn the engine switch off.
Inspect the battery positive terminal for
looseness.
Is there any malfunction?
Yes
Connect the battery positive terminal correctly,
then go to Step 10.
No
Go to the next step.
7
INSPECT GENERATOR CIRCUIT FOR
OPEN CIRCUIT
Inspect the continuity between
generator terminal B (wiring harness-
side) and battery positive terminal
Yes Go to the next step.
Repair or replace suspected part, then go to
2008 Mazda CX-9 Grand Touring
2008 ENGINE PERFORMANCE On-Board Diagnostic (MZI-3.7) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:08:40 AM
Page 286
© 2005 Mitchell Repair Information Company, LLC.
DTC P0626 [MZI-3.7]
DTC P0626 (MZI-3.7) DETECTION CONDITIONS AND POSSIBLE CAUSES
(wiring harness-side)
Is there continuity?
No
Step 10.
8
INSPECT PCM CONNECTOR FOR
POOR CONNECTION
Turn the engine switch off.
Inspect for poor connection (such as
damaged/pulled-out terminals,
corrosion).
Are there any malfunction?
Yes
Repair or replace suspected part, then go to
Step 10.
No
Go to the next step.
9
INSPECT GENERATOR
Inspect the generator. (See
GENERATOR INSPECTION [MZI-
3.7] .)
Is there any malfunction?
Yes
Replace the generator, then go to Step 10. (See
GENERATOR
REMOVAL/INSTALLATION [MZI-3.7] .)
No
Go to the next step.
10
VERIFY TROUBLESHOOTING OF DTC
P0625 HAS BEEN COMPLETED
Verify that all disconnected connectors
reconnected.
Clear the DTC from the PCM memory
using the M-MDS.
Perform the "KOEO or KOER self-
test" using the M-MDS. (See
KOEO/KOER SELF TEST [MZI-
3.7].)
Is the PENDING CODE for the DTC
present?
Yes
Replace the PCM, then go to the next step. (See
PCM REMOVAL/INSTALLATION [MZI-
3.7] .)
No
Go to the next step.
11
VERIFY AFTER REPAIR PROCEDURE
Perform the "AFTER REPAIR
PROCEDURE". (See AFTER
REPAIR PROCEDURE [MZI-3.7].)
Are any DTCs present?
Yes
Go to the applicable DTC inspection. (See
DTC TABLE [MZI-3.7].)
No
Troubleshooting completed.
DTC P0626
Generator field terminal circuit high
DETECTION
CONDITION
The PCM monitors generator load from the generator/regulator in the form of
frequency. The concern indicates the input is higher than the load should be in normal
operation. The load input could be high when a battery short to ground exists.
2008 Mazda CX-9 Grand Touring
2008 ENGINE PERFORMANCE On-Board Diagnostic (MZI-3.7) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:08:40 AM
Page 287
© 2005 Mitchell Repair Information Company, LLC.
DIAGNOSTIC PROCEDURE
DTC P0626 (MZI-3.7) DIAGNOSTIC PROCEDURE
POSSIBLE
CAUSE
Open circuit in wiring harness between generator terminal RC and PCM terminal 2S
Short to power supply between generator terminal RC and PCM terminal 2S
Short to power supply between generator terminal LI and PCM terminal 2AG
Connector or terminal malfunction
2008 Mazda CX-9 Grand Touring
2008 ENGINE PERFORMANCE On-Board Diagnostic (MZI-3.7) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:08:40 AM
Page 288
© 2005 Mitchell Repair Information Company, LLC.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.