Mazda CX-9 Grand Touring. Manual — part 535
DIAGNOSTIC PROCEDURE
DTC B266B - DIAGNOSTIC PROCEDURE
STEP
INSPECTION
ACTION
INSPECT WIRING HARNESS BETWEEN
PLG CONTROL UNIT AND PLG DRIVE
UNIT
Replace the PLG drive unit.
2008 Mazda CX-9 Grand Touring
2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:46:08 AM
Page 16
© 2005 Mitchell Repair Information Company, LLC.
DTC B266C [POWER LIFTGATE (PLG) SYSTEM]
DTC B266C - DETECTION CONDITION POSSIBLE CAUSE CHART
1
Disconnect the PLG control module
connector.
Disconnect the PLG drive unit connector.
Inspect the wiring harness between PLG
control module terminal 2J and PLG drive
unit terminal F for an open circuit/short
circuit to power supply system/short
circuit to ground system.
Is the wiring harness normal?
Yes
(See POWER LIFTGATE (PLG) DRIVE
UNIT REMOVAL/INSTALLATION .)
Go to the next step.
No
Repair or replace the wiring harness.
Go to the next step.
2
VERIFY CORRECTION COMPLETED
Reconnect the disconnected connector.
Clear the DTC.
Operate the PLG system.
Is DTC B266B stored?
Yes
Replace the PLG control module.
(See POWER LIFTGATE (PLG)
CONTROL MODULE
REMOVAL/INSTALLATION .)
No
DTC troubleshooting completed.
DTC B266C
Rotation sensor B circuit malfunction
DETECTION
CONDITION
Rotation sensor B signal does not change
POSSIBLE
CAUSE
Open circuit in wiring harness between PLG control module terminal 2L and PLG
drive unit terminal J Short to power supply in wiring harness between PLG control
module terminal 2L and PLG drive unit terminal J
Short to GND in wiring harness between PLG control module terminal 2L and PLG
drive unit terminal J
Rotation sensor malfunction
PLG control module malfunction
2008 Mazda CX-9 Grand Touring
2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:46:08 AM
Page 17
© 2005 Mitchell Repair Information Company, LLC.
DIAGNOSTIC PROCEDURE
DTC B266C - DIAGNOSTIC PROCEDURE
STEP
INSPECTION
ACTION
INSPECT WIRING HARNESS BETWEEN
PLG CONTROL UNIT AND PLG DRIVE
UNIT
Replace the PLG drive unit.
2008 Mazda CX-9 Grand Touring
2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:46:08 AM
Page 18
© 2005 Mitchell Repair Information Company, LLC.
DTC B266E [POWER LIFTGATE (PLG) SYSTEM]
DTC B266E - DETECTION CONDITION POSSIBLE CAUSE CHART
1
Disconnect the PLG control module
connector.
Disconnect the PLG drive unit connector.
Inspect the wiring harness between PLG
control module terminal 2L and PLG drive
unit terminal J for an open circuit/short
circuit to the power supply system/short
circuit to the ground system.
Is the wiring harness normal?
Yes
(See POWER LIFTGATE (PLG)
DRIVE UNIT
REMOVAL/INSTALLATION .)
Go to the next step.
No
Repair or replace the wiring harness.
Go to the next step.
2
VERIFY CORRECTION COMPLETED
Reconnect the disconnected connector.
Clear the DTC.
Operate the PLG system.
Is DTC B266C stored?
Yes
Replace the PLG control module.
(See POWER LIFTGATE (PLG)
DRIVE UNIT
REMOVAL/INSTALLATION .)
No
DTC troubleshooting completed.
DTC B266E
Rotation sensor malfunction
DETECTION
CONDITION
The PLG operation direction (open/close) and the PLG motor rotation direction from
the rotation sensor do not correspond.
POSSIBLE CAUSE
PLG arm malfunction
PLG slider malfunction
Torque cable malfunction
Reverse connection of the PLG motor
PLG drive unit (rotation sensor) malfunction
PLG control module malfunction
2008 Mazda CX-9 Grand Touring
2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:46:08 AM
Page 19
© 2005 Mitchell Repair Information Company, LLC.