Mazda Protege 5. Manual — part 157
EMISSION SYSTEM
01–16–18
POSITIVE CRANKCASE VENTILATION (PCV) SYSTEM FLOW DIAGRAM
A3U011613890W01
End Of Sie
POSITIVE CRANKCASE VENTILATION (PCV) VALVE INSPECTION
A3U011613890W02
1. Remove the PCV valve.
2. Blow through the valve and verify that air flows as
specified.
•
If not as specified, replace the PCV valve.
Specification
End Of Sie
Z3U0116W006
Condition
Airflow
Air applied from port A
Yes
Air applied from port B
No
X3U116WB8
1712-1U-01G(01-16).fm 18 ページ 2001年6月29日 金曜日 午前9時45分
EMISSION SYSTEM
01–16–19
01–16
WARM UP THREE-WAY CATALYTIC CONVERTER (WU-TWC) INSPECTION
A3U011620505W01
Note
•
Make sure that no HO2S DTC has been detected. If detected, this inspection cannot be used for WU-
TWC inspection.
1. Connect the WDS or equivalent and monitor PIDs as following.
•
Monitor the WU-TWC using O2S11 PID for upstream HO2S and O2S12 PID for downstream HO2S.
2. Begin to monitor the appropriate PIDs.
3. Drive the vehicle for 10 min at 65—96 km/h {40—60 mph} to ensure the WU-TWC reaches operating
temperature.
4. Stop the vehicle and leave in a safe place.
5. Let the engine at idle.
6. Record PIDs for 1 min.
7. Select the appropriate PIDs and read the graph.
8. Count the number of times (inversions) that the upstream HO2S graph line actually crosses the 0.5 V line.
9. Count the number of times (inversions) that the downstream HO2S graph line actually crosses the 0.5 V line.
Note
•
Do not count the number of peaks. Refer to the illustration.
10. Using the following equation, calculate the value of ratio.
Equation
RATIO = Upstream HO2S inversion
÷÷÷÷
downstream HO2S inversion
•
If the ratio is 2 or more or no downstream HO2S inversion, the WU-TWC is functioning properly.
•
If the ratio is less than 2, the WU-TWC is not functioning properly. Replace the WU-TWC.
Upstream HO2S graphline example
Z3U0116W011
Y3U116WAA
1712-1U-01G(01-16).fm 19 ページ 2001年6月29日 金曜日 午前9時45分
EMISSION SYSTEM
01–16–20
Downstream HO2S graphline example 1
Equation
RATIO = 26 inversions (upstream HO2S
inversions)
÷÷÷÷
7 inversions (downstream
HO2S inversions) = 3.7 (good WU-TWC)
Downstream HO2S graphline example 2
Downstream HO2S graphline example 3
Equation
RATIO = 26 inversions (upper stream HO2S
inversions)
÷÷÷÷
19 inversions (downstream
HO2S inversions) = 1.4 (deteriorated WU-
TWC)
End Of Sie
Z3U0116W008
Z3U0116W009
Z3U0116W010
1712-1U-01G(01-16).fm 20 ページ 2001年6月29日 金曜日 午前9時45分
CHARGING SYSTEM
01–17–1
01–17
01–17
CHARGING SYSTEM
BATTERY REMOVAL/INSTALLATION . 01–17–1
BATTERY INSPECTION . . . . . . . . . . . . . 01–17–1
Battery . . . . . . . . . . . . . . . . . . . . . . . . . 01–17–1
Back-up Current . . . . . . . . . . . . . . . . . . 01–17–2
BATTERY RECHARGING. . . . . . . . . . . . 01–17–2
GENERATOR
REMOVAL/INSTALLATION . . . . . . . . . . 01–17–3
Drive Belt Installation Note . . . . . . . . . . 01–17–3
GENERATOR INSPECTION . . . . . . . . . . 01–17–3
Generator Warning Light. . . . . . . . . . . . 01–17–3
Generator . . . . . . . . . . . . . . . . . . . . . . . 01–17–4
Current . . . . . . . . . . . . . . . . . . . . . . . . . 01–17–4
End of Toc
BATTERY REMOVAL/INSTALLATION
A3U011718520W01
1. Remove in the order indicated in the table.
2. Install in the reverse order of removal.
End Of Sie
BATTERY INSPECTION
A3U011718520W02
Battery
•
Inspect the battery in the following procedure.
1
Negative battery cable
2
Positive battery cable
3
Battery clamp
4
Battery box
5
Battery
6
Battery tray
X3U117WA0
Step
Inspection
Action
1
Measure open circuit
voltage of battery.
Above
12.4 V
Go to step
3.
Below
12.4 V
Go to next
step.
2
Quick charge for 30
minutes and recheck
voltage.
Above
12.4 V
Go to next
step.
Below
12.4 V
Replace
battery.
3
Apply load test (see load
test chart) to battery using a
battery load tester and
record battery voltage after
15 seconds. Is voltage
more than specification?
Yes
Battery is
okay.
No
Replace
battery.
1712-1U-01G(01-17).fm 1 ページ 2001年6月29日 金曜日 午前9時47分
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.