DAF 95XF. Manual — part 205
©
200438
1-17
EBS-2 fault codes
EBS-2
DAVIE XD diagnostics manual
12
75-16
Internal fault in the steering angle sensor (F701)
-
VSC system deactivated
75-18
Insufficient supply voltage on steering angle
sensor (F701) due to:
-
contact resistance or poor connection
-
interruption
-
VSC system deactivated
75-43
The steering angle sensor signal via CAN, from
the steering angle sensor (F701), is not correct or
not available
-
VSC system deactivated
75-63
No messages via CAN on pins B2 and B5 of the
EBS unit
-
VSC system deactivated
75-77
The EBS unit has not received a CAN message
from the steering angle sensor (F701) and VSC
module (F702) within a specified period of time
due to:
-
interruption on pin B15 of the EBS unit
-
VSC system deactivated
75-84
The parameters stored in the EBS unit and
covering the relation between the steering wheel
angular displacement and the wheel deflection
deviate from the current values measured while
the vehicle is being driven due to:
-
incorrect or other mechanical adjustment of
the steering gear
-
VSC system deactivated
Fault code
Fault code description with possible cause
Symptom
EBS-2
1-18
©
200438
EBS-2 fault codes
12
DAVIE XD diagnostics manual
©
200438
2-1
EBS-2 customer parameters
EBS-2
DAVIE XD diagnostics manual
12
2. EBS-2 CUSTOMER PARAMETERS
2.1 INTRODUCTION
Customer parameters
Customer parameters are the settings of an
electronic system. The customer parameters
permit adapting control functions of a system to
the customer's particular wishes and/or needs
within certain limits. The customer parameters
are stored in a list in the memory of the electronic
unit. Customer parameters can be modified using
the programming feature of DAVIE XD.
Programming using DAVIE XD is only possible if
the logged-in user has been registered as a
"Master Technician".
Note:
Erroneous settings of customer parameters may
affect the action of control functions to such an
extent that they function eratically or not at all.
After modification of the settings the (modified)
customer parameters must be stored in the
electronic unit using the programming function in
the customer parameter overview.
Customer parameter names and codes
Each customer parameter in a system has its
own name and code. The following explanation of
the customer parameters includes only the
codes. The availability of a customer parameter
in a system depends on the programmed
software in the electronic unit. The programmed
software depends on the vehicle configuration/
identity card data.
Standard values
Standard values, options and setting ranges may
vary according to the software variants of
DAVIE XD and the system. This is why they have
not been included in the following explanation of
the customer parameters.
EBS-2
2-2
©
200438
EBS-2 customer parameters
DAVIE XD diagnostics manual
12
2.2
E
X
P
LANATORY
NOTES
TO EBS
-2 CUS
TOMER P
ARAMET
E
RS
EBS Customer
para
meter
c
o
de
Exp
la
n
atio
n
D
e
p
en
de
nc
es:
Notes
Minimum
va
lu
e to be
se
t:
Ma
ximum
value
to
b
e
set:
3
-0
1
T
his is
a
co
mfort
p
arameter settin
g which de
te
rmi
nes
the pul
sing "P-in
sh
ot"
to the draw
n
ve
hicle
.
0
b
ar
3.5
bar
The
pressure
pulse
activation
"P insh
ot" is on
ly avai
lab
le
on FT
ve
hicle
s an
d is
o
nly active if
a
dra
w
n vehicl
e
without EBS
syste
m
is coup
led
.
Thi
s setting can
be
ch
ange
d if:
-
there
is
a compl
aint re
lati
ng
to the towing
of
the
d
ra
w
n vehi
cl
e when
b
ra
king is sta
rte
d.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.