DAF LF45, LF55 Series. Manual — part 36
©
1-1
CDS-3 fault codes
CDS-3
DAVIE XD diagnostics manual
7
1. CDS-3 FAULT CODES
1.1 INTRODUCTION
If the electronic unit detects a system fault, this
fault is usually stored in the memory of the
electronic unit as a fault code.
Most system faults will also generate a warning.
CDS-3
1-2
©
CDS-3 fault codes
7
DAVIE XD diagnostics manual
1.2 EXPLANATORY NOTES TO CDS-3 FAULT CODES
Fault code
Fault code description with possible cause
Symptom
2-4
-
Interruption of motor for central door lock on
co-driver's side (B200) on pin 12 of the ECU
-
Driver's door cannot be locked/unlocked
using the remote control
-
Co-driver's door cannot be locked using the
remote control
-
Co-driver's door cannot be locked using the
dashboard switch
-
Co-driver's door is not locked if the driver's
door is key-locked
-
Co-driver's door cannot be unlocked using
the dashboard switch
-
Driver's door is not locked if the co-driver's
door is key-locked
-
Interruption of motor for central door lock on
co-driver's side (B200) on pin 14 of the ECU
-
Driver's door cannot be unlocked using the
remote control
-
Interruption of motor for central door lock on
driver's side (B199) on pin 15 of the ECU
-
Driver's door cannot be locked using the
remote control
-
Co-driver's door cannot be locked using the
remote control when driver’s door is locked
-
Co-driver's door is not locked if the driver's
door is key-locked
-
Driver's door is not locked if the co-driver's
door is key-locked
3-6
Short circuit to earth on pin 2 of the ECU
-
Alarm system is not switched on when
operating the remote control
-
Alarm system is not switched off when
operating the remote control
-
Interior lighting does not respond to CDS-3
signal
©
2-1
System inspection with DAVIE XD
CDS-3
DAVIE XD diagnostics manual
7
2. SYSTEM INSPECTION WITH DAVIE XD
2.1 GENERAL
When replacing a CDS-3 electronic unit, the unit
must be initialised by means of DAVIE XD after
installation. Initialisation includes adjustment of
the two remote controls.
CDS-3
2-2
©
System inspection with DAVIE XD
7
DAVIE XD diagnostics manual
2.2 MENU "INITIALISING NEW UNIT"
The option "Initialising new unit" can be found in
the menu "Programming".
This menu consists of three components:
-
activating remote controls
-
deactiving remote controls
-
Initialising new unit
Activating hand-held transmitters
2 remote controls come standard with each CDS-
3 unit. Another 6 remote controls may be added.
Deactivating hand-held transmitters
With this option it is possible to deactivate remote
controls, for instance when one of the remote
controls has been lost. With this option all remote
controls are deactivated, so that at least two
remote controls will need to be adjusted once
again.
Initialising new unit
Only a new "empty" unit can be initialised. Once
initialised, a unit cannot be initialised again with
this DAVIE XD option.
Having installed the unit, go to menu
"Programming" in DAVIE XD and select option
"Initialising new unit".
It is necessary to adjust at least two remote
controls. The remote control has been adjusted
when it recognises the signal sent by the remote
control.
The unit must have recognised this signal four
times and this needs to be true for both remote
controls.
Should something go wrong during initialisation
and should the procedure be aborted because of
this, the procedure can be repeated after
renewed startup. A unit, once initialised, cannot
be initialised again.