DAF CF65, CF75, CF85 Series . Manual — part 580
10
37
1358030/26
EL001357
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
1208
1208
1208
4523
4523
4520
4521
1208
1208
4521
4520
1208
1207
1207
4522
4522
4524
4524
4525
1233
1207
1207
1207
4525
4521
4520
4520
4521
4525
1233
1233
4529
1233
1233
1208
1208
1208
1208
4527
4527
4526
4526
4528
4528
4529
D929
1010
1000
1010
1000
E044
10A
E033
15A
E034
15A
26/400
2
591
2
553
C695
4
19
8
591
6
553
5
553
6
591
5
591
4
591
3
591
17/401
7
591
8
553
4
553
3
553
7
553
35/401
C746
1
19
G029
30
85
86
87A
87
G028
30
85
86
87A
87
M
1
2
B004
G031
30
85
86
87A
87
G030
30
85
86
87A
87
M
1
2
B003
C743
2
53
4
1
II
0
I
C744
2
53
4
1
II
0
I
C745
2
53
4
1
II
0
I
200404
2-160
5
ELECTRICAL SYSTEM
Electrical system
CF65/75/85 series ≥0E621376
10
200404
2-161
Electrical system
5
ELECTRICAL SYSTEM
CF65/75/85 series ≥0E621376
10
38
MECHANICAL
LIFTING
GEAR
Manual
lifting
When
switch
C739
(mechanical
lifting
gear
switch)
is
operated
(connection
between
contacts
3
and
7),
a
voltage
is
applied
to
connection
point
1
of
B
071
through
fuse
E062,
wire
1221,
contacts
3
-
7
of
switch
C739,
wire
4550,
contacts
3
-
4
of
relay
G381
and
wire
5180.
This
valve
is
energised.
At
the
same
time
the
voltage
is
applied
to
connection
point
85
of
relay
G
052
through
D622,
wire
4552,
contacts
30
-
87a
of
relay
G
066,
wire
4557.
This
relay
is
activated
and
closes
contacts
1
-
2.
A
voltage
is
now
applied
to
connection
point
1
of
B
073
through
contacts
1
-
2
of
relay
G052,
wire
4554.
The
oil
pump
motor
starts
to
run.
If
the
oil
pressure
becomes
too
high
(>160
bar),
E524
will
close.
V
oltage
is
now
applied
to
connection
point
85
of
relay
G
066
through
contacts
1
-
2
of
E
524.
This
relay
is
energised
and
breaks
the
connection
30
-
87a.
V
oltage
is
now
applied
to
connection
point
85
of
relay
G066
from
wire
4552
through
contacts
30
-
87
of
relay
G
066
and
wire
4558.
This
relay
continues
to
be
activated.
At
the
same
time
the
voltage
through
relay
G
052
is
lost.
Contacts
1
-
2
open
and
the
voltage
on
connection
point
1
of
B
073
is
lost.
T
he
pump
motor
is
no
longer
driven
and
the
oil
pressure
drops.
Manual
lowering
When
switch
C739
(mechanical
lifting
gear
switch)
is
operated
(connection
between
contacts
3
and
1),
a
voltage
is
applied
to
connection
point
S1
of
D503
through
fuse
E062,
wire
1221,
contacts
3
-
1
of
switch
C739,
wire
4757,
through-connection
G745
and
wire
4551.
A
voltage
is
applied
to
connection
point
1
of
B
072
through
connection
point
87
of
D503,
wire
4553.
This
valve
is
energised.
At
the
same
time
the
voltage
is
applied
to
connection
point
85
of
relay
G
052
through
D623,
wire
4552,
contacts
30
-
87a
of
relay
G
066,
wire
4557.
This
relay
is
activated
and
closes
contacts
1
-
2.
A
voltage
is
now
applied
to
connection
point
1
of
B073
through
contacts
1
-
2
of
relay
G052,
wire
4554.
The
oil
pump
m
otor
starts
to
run.
If
the
oil
pressure
becomes
too
high
(>160
bar),
E524
will
close.
V
oltage
is
now
applied
to
connection
point
85
of
relay
G
066
through
contacts
1
-
2
of
E
524.
This
relay
is
energised
and
breaks
the
connection
30
-
87a.
V
oltage
is
now
applied
to
connection
point
85
of
relay
G066
from
wire
4552
through
contacts
30
-
87
of
relay
G
066
and
wire
4558.
This
relay
continues
to
be
activated.
At
the
same
time
the
voltage
through
relay
G
052
is
lost.
Contacts
1
-
2
open
and
the
voltage
on
connection
point
1
of
B
073
is
lost.
T
he
pump
motor
is
no
longer
driven
and
the
oil
pressure
drops.
Automatic
axle
load
p
rotection
If
th
ep
re
ss
ur
e
on
th
ed
riv
ena
xl
ei
sg
re
at
er
than
the
legal
maximum,
sensor
E584
is
activated.
This
puts
sensor
E507
in
‘stand-by’
mode.
If
the
permitted
axle
load
increases
further
(>
10
tons),
sensor
E507
automatically
lowers
the
trailing
axle.
If
the
axle
has
been
lifted,
F097
(proximity
switch
for
m
echanical
trailing
axle
lifting
gear)
ensures
that
relay
G
380
is
energised
through
wire
3661.
A
voltage
is
now
applied
through
fuse
E062,
wire
1221,
contacts
3
-
5
of
relay
G380
to
connection
point
1
of
E
507.
This
relay
is
activated.
The
voltage
is
immediately
transmitted
to
S
2
on
D503.
The
signal
sent
by
the
proximity
switch
for
axle
load
protection
(E507)
to
S2
should
last
for
at
least
10
seconds
before
the
electronic
unit
for
lifting
gear
(D503)
will
activate
the
valve
(B072)
and
the
lifting
gear
pump
m
otor
(B073),
so
that
the
trailing
axle
is
lowered.
This
is
to
prevent
the
legal
maximum
axle
load
from
being
exceeded.
If
the
dashboard
switch
is
operated
within
2.5
minutes,
the
electronic
unit
w
ill
be
reset
and
another
2.5
m
inute
period
w
ill
start.
200404
2-162
5
ELECTRICAL SYSTEM
Electrical system
CF65/75/85 series ≥0E621376
10
As
a
result,
the
m
echanical
lifting
gear
motor
relay
(G052)
will
also
be
activated,
thus
activating
the
m
echanical
lifting
gear
pump
(B073).
T
his
is
done
through
D623,
relay
G066
(connection
between
points
30
and
87a)
to
connection
point
85
of
relay
G
052.
When
a
pressure
of
160
bar
is
reached,
the
limit
switch
(E524)
switches
the
lifting-gear
pump
m
otor
(B073)
of
ft
hrough
relay
G
066
and
relay
G
052.
The
trailing
axle
cannot
be
lifted
for
a
period
of
2.5
m
inutes
as
the
valve
(B072)
remains
energised.
This
valve
should
be
in
the
non
-activated
position
for
lifting.
VARIANTS
Location 40
G745:
In
connector
882,
pin
20
there
is
a
w
ire,
4757.
In
the
other
side
there
is
w
ire
4551.
G745
is
formed
by
the
pin
connection.
200404
2-163
Electrical system
5
ELECTRICAL SYSTEM
CF65/75/85 series ≥0E621376