DAF CF65, CF75, CF85 Series . Manual — part 736
V
ARIANTS
Location
24
Only
if
the
v
ehicle
has
been
fitted
out
to
meet
PETREG
specifications.
31
Connect
w
ire
1234
to
dashboard
wiring
harness
in
c
entral
box
(see
illustration).
34
Connect
w
ire
4179
to
dashboard
wiring
harness
in
c
entral
box
(see
illustration).
39
Attach
wire
4176
to
pin
1
1
o
f
connector
570.
41
Attach
wire
4177
to
pin
1
2
o
f
connector
570.
44
Attach
wire
1
123
to
pin
2
instead
of
wire
1
127.
Isolate
w
ire
1
127.
47
Attach
wire
9303
to
pin
2
0
instead
of
wire
9001.
Isolate
w
ire
9001.
50
Only
if
the
v
ehicle
has
been
fitted
out
to
meet
PETREG
specifications.
E501496
1234
4179
0202
ᓻ
2-40
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
1358030/15
EL000487
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
1
1008
3173
1000
4176
3173
1167
1167
1167
1167
1167
4178
4178
4176
9306
4176
4174
4174
4175
4174
4175
4174
4175
4175
1009
1009
1167
1167
4176
9306
4176
1167
1167
4177
4177
4177
4177
4176
4179
4179
4179
4179
1234
1234
1234
1234
1234
1234
1127
1123
1123
1123
9001
9303
9303
9303
4178
1010
1000
1000
1010
1000
1008
1107
1107
1107
1107
1107
1107
1107
A500
11
570
4
639
4
638
12
570
3
638
3
639
1
671
7
639
5
638
4
671
3
671
G525
1/416
1/417
E330
5A
2
1
E286
125A
2
1
G367
88
88A
85A
85B
86
G368
88
88A
85A
85B
86
C853
5
71
0I
C854
1
2
!
!
!
6
639
6
638
2
555
8
639
1
638
20
555
!
!
A5
A7
C2
C5
C4
A2
C1
A3
A4
A1
D924
30
87
G015
E153
10A
12
B525
1/
598
5/
598
D826
++
+
G425
30
85
86
87A
87
!
2
671
2
639
2
638
!
1
554
20
554
1
C010
1
2
C011
1
2
15/403
D929
1010
1000
1000
1010
E028
15A
!
0202
ᓻ
2-41
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
2
IGNITION/ST
ARTER
SWITCH/CHARGING
C
IRCUIT
IGNITION
CIRCUIT
If
ignition/starter
s
witch
C
539
is
turned
(contact
1
is
connected
to
p
in
6),
the
“accessories
”
relay
(G178)
will
be
activated.
V
o
ltage
is
now
applied
through
fuse
E037,
switch
C539
and
wire
1
130
to
contact
8
5
o
f
relay
G
178.
As
a
result
o
f
the
activation
of
relay
G
178
a
c
onnection
is
made
between
contacts
30
and
87
and
a
v
oltage
is
applied
through
fuse
E052
and
wire
1
1
1
0
to
the
work
lamp
switch
(C725)
and
the
m
icrorelay
(G377)
for
the
accessories
power
supply
to
the
radio.
ST
ARTER
CIRCUIT
If
the
ignition
switch
C539
is
turned
(contact
1
is
connected
to
4
),
contact
relay
G015
will
be
activated
v
ia
wire
4001.
When
the
ignition
switch
is
turned
to
the
“start
”
position,
points
1
and
2
in
this
s
witch
are
c
onnected.
The
power
is
now
supplied
from
the
batteries
through
fuse
E037,
the
connection
1-2
o
f
the
ignition/starter
s
witch
and
wire
4004
on
connection
point
3
o
f
the
alarm
system.
When
the
a
larm
system
has
been
switched
of
f
using
the
remote
control,
or
by
turning
o
n
the
ignition
(the
immobiliser
switches
the
a
larm
of
f
via
C
AN),
wire
4004
is
connected
to
4004A.
Relay
G
203
coil
will
be
activated.
This
closes
the
3
0
-
8
7
c
onnection.
A
v
oltage
is
now
applied
to
c
onnection
point
50
of
the
starter
m
otor
through
fuse
E037,
wire
1
100,
relay
c
ontacts
30
-
8
7
and
wire
4002
so
that
the
s
tarter
motor
s
tarts
running.
When
the
a
larm
has
been
switched
of
f
and
the
door
has
opened,
the
s
tart
interrupter
will
be
deactivated
for
60
seconds.
If
the
engine
is
not
started
w
ithin
this
time,
the
s
tart
interrupter
is
reactivated.
If
the
a
larm
is
switched
of
f
and
the
doors
a
re
not
opened,
the
s
tart
interrupter
remains
deactivated
for
9
minutes.
When
the
immobiliser
applies
a
voltage
to
wire
4009,
the
c
ab
heater
is
also
switched
of
f
if
the
v
ehicle
m
ust
m
eet
requirements
for
the
transportation
of
hazardous
substances.
CHARGING
C
IRCUIT
When
the
ignition
is
switched
on,
power
is
supplied
to
both
the
B+
connection
and
connection
15
of
the
a
lternator
.
An
internal
resistor
in
the
alternator
is
energised
b
y
a
n
IC
in
the
carbon
brush
holder
.
This
resistor
ensures
that
a
low
level
o
f
current
passes
through
the
energising
resistor
.
T
his
e
xcites
a
magnetic
field
in
the
alternator
.
After
s
tarting,
the
v
oltage
on
terminals
B
+
and
15
will
rise
to
about
28.5
V
.
O
nce
this
v
oltage
is
reached,
the
IC
in
the
regulator
interrupts
the
pre-exciter
c
oil
to
enable
the
voltage
to
be
controlled.
The
m
agnetic
field
w
ill
now
disappear
,
s
o
that
the
generator
will
not
be
energised
for
a
s
hort
period
o
f
time.
As
a
result,
the
v
oltage
on
outputs
B
+
and
B15
will
drop.
The
regulator
reactivates
w
hen
the
v
oltage
drops
below
27.6
V
.
T
his
m
eans
that
the
generator
voltage
supply
remains
relatively
constant.
T
he
batteries
are
supplied
through
the
B
+
generator
output.
The
a
lternator
charging
current
warning
light
is
activated
v
ia
wire
1020
that
is
connected
to
the
V
IC.
(D900).
T
he
VIC
c
ontrols
the
D
IP
via
the
C
AN
network.
T
he
voltage
on
wire
1020
is
supplied
b
y
the
control
IC.
The
a
lternator
also
has
a
’sens
’
line.
This
connection
continuously
measures
the
v
oltage
on
connection
point
30
of
the
s
tarter
motor
.
If
the
v
oltage
on
connection
point
30
drops,
the
voltage
is
immediately
c
orrected
b
y
the
control
IC.
The
a
lternator
will
increase
the
voltage
until
a
v
alue
of
28.5
V
is
reached
again.
V
ARIANTS
Location
42
If
there
is
n
o
a
larm
system,
w
ire
4004
and
4004A
are
c
onnected
in
connector
603.
0202
ᓻ
2-42
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
2
1358030/15
EL000489
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
1000
1010
1000
1000
1130
3084
1100
1100
1020
1000
1000
4002
4002
1000
1000
3084
1234
4009
4009
1000
1000
1100
1130
1234
3157
1234
1234
1234
1147
1110
1110
1110
4004A
4004A
4004A
4004
4004
1234
3157
4009
1010
1100
4001
4009
4001
1000
1020
1020
4004
1130
1100
4009
4002
A500
G014
1
5
D901
11
42
C725
5
23
30
87
86
85
G015
50
B010
M
31
30
G
3
B
B+
L
15
S
A513
10
575
20
575
2
582
2
558
16
574
1/416
1/417
23/400
19/402
1/402
32/400
34/400
3/402
20/402
15/402
25/403
26/403
24/403
G525
E286
125A
2
1
E279
5A
12
C539
1/222
2/222
4/222
6/222
D929
1010
1000
E037
15A
1000
1010
E143
10A
30
86
85
87A
87
G178
1130
1100
1110
4004
3157
E052
10A
G372
31
2
45
87
30
86
85
G203
19/403
2/403
29/
595
D900
42/
594
D911
1/
603
3/
603
7
575
14
574
DVB
!
0202
ᓻ
2-43
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF