DAF CF65, CF75, CF85 Series . Manual — part 735
MAIN
SWITCH
FOR
PETREG
If
the
v
ehicle
has
an
Allison
gearbox
and
the
system
must
meet
specific
safety
requirements,
wire
no.
1009
(Allison
power
supply)
should
b
e
c
onnected
to
c
onnection
88a
of
relay
G
367.
The
earth
connection
of
D866
should
b
e
connected
to
c
onnection
88
of
relay
G
368.
Basic
c
ode
Description
A500
Batteries
A513
Integrated
voltage
regulator
generator
B525
T
a
chograph
C010
Driver
’s
s
ide
c
orner
marker
light
C01
1
Co-driver
’s
s
ide
c
orner
marker
light
C853
Switch
for
m
ain
s
witch
in
cab
C854
Switch
for
m
ain
s
witch
o
n
chassis
D826
Electronic
unit
for
VLG
current
limiter
D900
Electronic
unit
for
VIC
L
F
65/5785
D924
Electronic
unit,
main
switch
E045
Cab
interior
lighting
fuse
E1
17
Fuse
for
v
isibility
lighting
E153
Fuse
for
engine
stop
main
switch
before
m
ain
s
witch
E286
High
capacity
fuse
E330
Main
switch
’sens
’-wire
fuse
G367
Main
switch
power
supply
relay
G368
Main
switch
earth
relay
G425
Main
switch
relay
0202
ᓻ
2-36
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
E501326
30
87
87A
G368
1
2
1
2
C010
C011
1107
1000
1000
1167
1
2
+
+
-
-
1
2
5
86
85
85B
86
86
85B
85A
88
88A
88
88A
1
1
0
1
2
2
2
0
7
A
B
E286
1
2
E045
G367
A500
E153
1
2
E330
4177
C854
C4
C5
A7
A2
C1
C2
A1
A3
A4
A5
2630
1234
1234
4179
9306
1123
1
4
3
9001
1009
4176
4178
E117
1010
1010
A5
B525
9303
A1
B525
15
A513
E1
D900
C853
1167
4175
4174
3173
G425
G367
85A
G368
G425
D924
D826
0202
ᓻ
2-37
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
The
m
ain
s
witch
(D924)
can
b
e
c
losed:
-
Electrically
in
the
c
ab
-
Electrically
on
the
c
hassis
Closing
the
main
s
witch
e
lectrically
in
the
cab
E501126
A
TTN:
s
witch
C
854
must
be
in
the
“
main
switch
on
”
position
(connection
b
etween
contacts
1
-
2
).
Switch
C853
(switch
for
main
switch
in
cab)
connects
the
C
1
and
C2
connections
to
the
C4
and
C5
connections
via
w
ire
4176,
c
o
n
ta
c
ts
5-7o
fs
w
it
c
hC
853,
wire
4177,
c
o
n
ta
c
ts
1-2o
fs
w
it
c
hC
8
5
4
a
n
d
w
ir
e
4178.
Relays
G367
and
G368
are
immediately
energised
v
ia
wire
4174
and
connection
point
A3
(A3
is
c
onnected
to
earth
for
0
.5
seconds).
This
closes
the
c
onnection
between
point
88a
and
88
of
both
relay
G367
and
relay
G
368.
The
positive
and
negative
poles
of
the
batteries
are
now
connected
to
the
vehicle
’s
power
supply
Immediately
a
fter
s
witch
C
853
closes,
connection
point
C2
is
internally
connected
to
point
A7.
Connection
point
A5
is
connected
to
the
positive
pole
v
ia
wire
3173
after
c
onnection
point
88
of
relay
G
367.
This
connection
transmits
a
s
ignal
to
the
E
CU
to
indicate
that
relay
G
367
has
switched.
Closing
the
main
s
witch
e
lectrically
on
the
chassis
A
TTN:
s
witch
C
853
must
be
in
the
“
main
switch
on
”
position
(connection
b
etween
contacts
5
-
7
).
Switch
C854
(switch
for
main
switch
on
the
chassis)
connects
the
C
1
c
onnection
to
the
C4
and
C5
connections
via
w
ire
4176,
c
o
n
ta
c
ts
5-7o
fs
w
it
c
hC
853,
wire
4177,
c
o
n
ta
c
ts
1-2o
fs
w
it
c
hC
8
5
4
a
n
d
w
ir
e
4178.
Relays
G367
and
G368
are
immediately
energised
v
ia
wire
4174
and
connection
point
A3
(A3
is
c
onnected
to
earth
for
0.5
s
econds).
This
closes
the
c
onnection
between
point
88a
and
88
of
both
relay
G367
and
relay
G368.
The
positive
and
negative
poles
of
the
batteries
are
now
connected
to
the
vehicle
’s
power
supply
Immediately
a
fter
s
witch
C
854
closes,
connection
point
C2
is
internally
connected
to
point
A7.
Connection
point
A5
is
connected
to
the
positive
pole
v
ia
wire
3173
after
c
onnection
point
88
of
relay
G367.
This
connection
transmits
a
s
ignal
to
the
E
CU
to
indicate
that
relay
G367
has
switched.
The
m
ain
s
witch
(D924)
can
b
e
opened:
-
Electrically
in
the
c
ab
-
Electrically
on
the
c
hassis
Opening
the
main
s
witch
e
lectrically
in
the
cab
E501126
A
TTN:
s
witch
C854
must
be
in
the
“
main
switch
on
”
position
(connection
b
etween
contacts
1
-
2
).
0202
ᓻ
2-38
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
Switch
C853
(switch
for
main
switch
in
cab)
disconnects
wire
4176,
contacts
5-7o
f
switch
C853,
wire
4177,
contacts
1-2o
f
switch
C854
and
the
C
1
and
C2
connections
from
the
C
4
and
C5
connections
via
w
ire
4178.
T
w
o
a
ctions
are
c
arried
out
immediately
a
fter
switch
C853
is
opened:
1.
Connection
point
A7
is
connected
to
earth
(A2).
2.
After
a
delay
of
approx.
6
seconds,
relay
G367
and
G368
are
c
onnected
to
earth
for
approx.
0
.5
seconds
via
w
ire
4175
and
connection
point
A4.
T
his
b
reaks
the
connection
between
point
88a
and
88
of
relay
G
367
and
G368.
The
positive
and
negative
poles
of
the
batteries
are
now
disconnected
from
the
vehicle
’s
power
supply
If
the
engine
is
running,
it
is
switched
of
f.
Connection
point
A5
is
connected
to
the
positive
pole
v
ia
wire
3173
after
c
onnection
point
88
of
relay
G
367.
This
connection
transmits
a
s
ignal
to
the
E
CU
to
indicate
that
relay
G
367
has
switched.
Opening
the
main
s
witch
electrically
on
the
c
hassis
A
TTN:
s
witch
C
853
must
be
in
the
“
main
switch
on
”
position
(connection
b
etween
contacts
5
-
7
).
Switch
C854
(switch
for
main
switch
in
cab)
breaks
the
connection
from
C1
and
C2
to
C4
and
C5
via
w
ire
4176,
contacts
5-7o
fs
w
it
c
h
C853,
wire
4177,
contacts
1-2o
fs
w
it
c
h
C854
and
wire
4178.
T
w
o
a
ctions
are
c
arried
out
immediately
a
fter
switch
C854
is
opened:
1.
Connection
point
A7
is
connected
to
earth
(A2)
in
the
unit.
2.
After
a
delay
of
approx.
6
seconds,
relay
G367
and
G368
are
connected
to
earth
for
approx.
0
.5
seconds
via
w
ire
4175
and
connection
point
A4.
T
his
b
reaks
the
connection
between
point
88a
and
88
of
relay
G
367
and
G368.
The
positive
and
negative
poles
of
the
batteries
are
now
disconnected
from
the
vehicle
’s
power
supply
If
the
engine
is
running,
it
is
switched
of
f.
Connection
point
A5
is
connected
to
the
positive
pole
v
ia
wire
3173
after
c
onnection
point
88
of
relay
G367.
This
connection
transmits
a
s
ignal
to
the
E
CU
to
indicate
that
relay
G367
has
switched.
Note:
When
one
of
the
s
witches
(C853
or
C854)
that
activate
the
e
lectronic
unit
(close
m
ain
switch)
a
re
operated,
relay
G
367
and
G368
are
a
ctivated
after
approximately
3
seconds.
If
one
of
the
s
witches
is
operated
again
w
ithin
the
3
s
econds,
the
electronic
unit
(D924)
will
select
the
priority
’main
switch
ON
’.
0202
ᓻ
2-39
5
ELECTRICAL SYSTEM
Electrical system
series
65/75/85
CF
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.