Honda Odyssey 2004. Manual — part 563
−
−
−
−
*06
*10
*07
20
YES
NO
YES
NO
23-194
SRS
DTC Troubleshooting (cont’d)
A
C503
DASHBOARD WIRE HARNESS
8P CONNECTOR
OPDS UNIT HARNESS
8P CONNECTOR D
C851
A
SRS MAIN HARNESS 28P CONNECTOR
33. Disconnect the SRS main harness 8P connector (A)
from the dashboard wire harness 8P connector
C503.
34. Check resistance between the No. 1 terminal of the
dashboard wire harness 8P connector and the No. 7
terminal of the OPDS unit harness 8P connector D.
There should be 1
or less.
Open in the SRS main harness; replace the
SRS main harness.
Open in the dashboard wire harness, right
side wire harness, or OPDS unit harness; replace
the faulty harness.
35. Turn the ignition switch OFF.
36. Disconnect the SRS main harness 28P connector
(A) from the SRS floor harness 28P connector C851.
37. Turn the ignition switch ON (II).
38. Check for voltage between the No. 16 terminal of
the SRS main harness 28P connector and body
ground. There should be 0.5 V or less.
Short to power in the SRS floor harness;
replace the SRS floor harness.
Go to step 39.
Terminal side of male terminals
Wire side of female terminals
Wire side of female terminals
Is the r esistance as specif ied?
Is the voltage as specif ied?
03/07/29 10:36:34 61S0X050_230_0194
−
−
*08
22
YES
NO
23-195
A
C503
DASHBOARD WIRE HARNESS 8P CONNECTOR
39. Turn the ignition switch ON (II).
40. Disconnect the SRS main harness 8P connector (A)
from the dashboard wire harness 8P connector
C503.
41. Turn the ignition switch ON (II).
42. Check for voltage between the No. 1 terminal of the
dashboard wire harness 8P connector and body
ground. There should be 0.5 V or less.
Short to power in the SRS main harness;
replace the SRS main harness.
Short to power in the dashboard wire harness
or right side wire harness or OPDS unit harness;
replace the faulty harness.
Terminal side of male terminals
Is the voltage as specif ied?
03/07/29 10:36:35 61S0X050_230_0195
−
−
−
−
−
−
−
−
−
−
*01
02
S0X4AC5K79100081152FAAT00
’02 Model
DTC 15-2:
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
23-196
SRS
DTC Troubleshooting (cont’d)
A
D
OPDS UNIT HARNESS CONNECTOR D (8P)
Faulty Side Airbag Cutoff Indicator
Circuit
NOTE: This DTC may have been caused by:
• Blown or removed fuses in certain circuits (such as
odometer) with the ignition switch in the ON (II)
position.
• Any part of the SRS circuit (particulary the gauge
assembly) is disconnected with the ignition switch in
the ON (II) position.
1. Erase the DTC memory (see page 23-38).
2. Turn the ignition switch ON (II), and check that the
SRS indicator comes on for about 6 seconds and
then goes off.
Go to step 3.
Intermittent failure, system is OK at this time.
Go to Troubleshooting Intermittent Failures (see
page 23-39).
3. Turn the ignition switch OFF. Make sure nothing is
on the front passenger’s seat.
4. Turn the ignition switch ON (II), and check that the
side airbag cutoff indicator comes on.
Go to step 5.
Go to step 6.
5. Make sure the side airbag cutoff indicator comes
on for 5 seconds and then goes off.
Faulty OPDS unit or SRS unit; replace the
OPDS unit (see page 23-387). If the problem is still
present, replace the SRS unit (see page 23-382).
Go to step 35.
6. Turn the ignition switch OFF.
7. Check the No. 9 (10A) fuse in the under-dash
fuse/relay box.
Go to step 8.
Repair the short to ground in the No. 9 (10A)
fuse circuit.
8. Disconnect the OPDS unit harness 8P connector D
from the OPDS unit (A).
9. Turn the ignition switch ON (II).
10. Check for voltage between the No. 3 terminal of the
OPDS unit harness connector D (8P) and body
ground. There should be battery voltage.
Go to step 11.
Go to step 23.
Wire side of female terminals
Does the SRS indicator stay on?
Does the side air bag cutof f indicator come on?
Does the side air bag cutof f indicator go of f ?
Is the f use OK ?
Is ther e batter y voltage?
03/07/29 10:36:35 61S0X050_230_0196
−
−
−
−
03
04
01
06
YES
NO
YES
NO
23-197
I
OPDS UNIT HARNESS CONNECTOR D (8P)
A
OPDS UNIT HARNESS CONNECTOR D (8P)
11. Turn the ignition switch OFF.
12. Disconnect the driver’s under-dash fuse/relay box
connector I from the under-dash fuse/relay box.
13. Turn the ignition switch ON (II).
14. Check for voltage between the No. 3 terminal of the
OPDS unit harness connector D (8P) and body
ground. There should be 0.5 V or less.
Faulty OPDS unit; replace the OPDS unit (see
page 23-387).
Go to step 15.
15. Turn the ignition switch OFF.
16. Disconnect gauge assembly connector A (14P)
from the gauge assembly (see page 22-100).
17. Turn the ignition switch ON (II).
18. Check for voltage between the No. 3 terminal of
OPDS unit harness connector D (8P) and body
ground. There should be 0.5 V or less.
Short to power in the gauge assembly;
replace the gauge assembly.
Go to step 19.
(cont’d)
Wire side of female terminals
Wire side of female terminals
Is the voltage as specif ied?
Is the voltage as specif ied?
03/07/29 10:36:36 61S0X050_230_0197