Mitsubishi Outlander (2003+). Manual — part 500
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-289
Step 4. Connector check: D-05 front room lamp
connector, D-11 rear room lamp connector
Q: Is the check result normal?
YES :
Go to Step 5.
NO :
Repair the defective connector.
Step 5. Check the bulbs of the front or rear room
lamps.
Check that the front or rear room lamp bulbs are not
burned out.
Q: Is the check result normal?
YES :
Go to Step 6.
NO :
Replace the front or rear room lamp bulb.
Step 6. Connector check: C-217 ETACS-ECU
connector
Q: Is the check result normal?
YES :
Go to Step 7.
NO :
Repair the defective connector.
AC308781
Connector: D-05
2
1
Harness side
AF
<LHD>
AC308785
Connector: D-05
2
1
Harness side
AE
<RHD>
AC308783
Connector: D-11
AE
Harness side
2 1
D-11(GR)
<LHD>
AC308787
Connector: D-11
AD
Harness side
2 1
D-11(GR)
<RHD>
AC308722
Connector: C-217
Junction block (Rear view)
Junction block side
AD
3
1
2
14
4
5
7 6
8
1110 9
1312
17
15
16
18
19
20
<LHD>
AC308776
Connector: C-217
Junction block (Rear view)
Junction block side
AC
3
1
2
14
4
5
7 6
8
1110 9
1312
17
15
16
18
19
20
<RHD>
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-290
Step 7. Check the wiring harness from C-217
ETACS-ECU connector terminal Nos. 5 and 6 to
D-05 front room lamp connector terminal Nos. 2
and 1.
NOTE:
Prior to the wiring harness inspection, check junction
block connector C-210, and repair if necessary.
Q: Is the check result normal?
YES :
Go to Step 8.
NO :
Repair the wiring harness.
AC308722
Connector: C-217
Junction block (Rear view)
Junction block side
AD
3
1
2
14
4
5
7 6
8
1110 9
1312
17
15
16
18
19
20
<LHD>
AC308776
Connector: C-217
Junction block (Rear view)
Junction block side
AC
3
1
2
14
4
5
7 6
8
1110 9
1312
17
15
16
18
19
20
<RHD>
AC308781
Connector: D-05
2
1
Harness side
AF
<LHD>
AC308785
Connector: D-05
2
1
Harness side
AE
<RHD>
AC308720
Connector: C-210
Harness side
AK
3
1
2
Junction block (Front view)
<LHD>
AC308772
Connector: C-210
Harness side
AJ
3
1
2
Junction block (Front view)
<RHD>
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-291
Step 8. Check the wiring harness from C-217
ETACS-ECU connector terminal Nos. 5 and 6 to
D-11 rear room lamp connector terminal Nos. 2
and 1.
NOTE:
Prior to the wiring harness inspection, check junction
block connector C-210, and repair if necessary.
Q: Is the check result normal?
YES :
Go to Step 9.
NO :
Repair the wiring harness.
Step 9. Retest the system.
Check that the front or rear room lamp illuminates
and extinguishes normally.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
−
How to
Cope with Intermittent Malfunction
NO :
Replace the ETACS-ECU.
AC308722
Connector: C-217
Junction block (Rear view)
Junction block side
AD
3
1
2
14
4
5
7 6
8
1110 9
1312
17
15
16
18
19
20
<LHD>
AC308776
Connector: C-217
Junction block (Rear view)
Junction block side
AC
3
1
2
14
4
5
7 6
8
1110 9
1312
17
15
16
18
19
20
<RHD>
AC308783
Connector: D-11
AE
Harness side
2 1
D-11(GR)
<LHD>
AC308787
Connector: D-11
AD
Harness side
2 1
D-11(GR)
<RHD>
AC308720
Connector: C-210
Harness side
AK
3
1
2
Junction block (Front view)
<LHD>
AC308772
Connector: C-210
Harness side
AJ
3
1
2
Junction block (Front view)
<RHD>
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-292
INSPECTION PROCEDURE M-3: Interior lamp automatic shutoff function does not work normally.
<Vehicles with keyless entry system>
CAUTION
Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
The ETACS-ECU operates the interior lamp
automatic-shutdown function in accordance with the
input signals below.
•
Ignition switch (ACC)
•
Ignition switch (IG1)
•
Driver's door switch
•
All of the door switches
•
Interior lamp loaded signal
If this function does not work normally, these input
signal circuit(s) or the ETACS-ECU may be
defective. Note that this function can be
disabled/enabled by the adjustment function (default
setting; enabled).
POSSIBLE CAUSES
•
Malfunction of the door switches
•
Malfunction of the room lamp
•
Malfunction of the ETACS-ECU
•
Damaged harness wires and connectors
DIAGNOSTIC PROCEDURE
Step 1. Check the adjustment function.
Check that the interior lamp automatic-shutdown
function has been enabled by using the adjustment
function.
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Enable the interior lamp
automatic-shutdown function by using the
adjustment function. Refer to
INPUT SIGNAL
COMBINATION
METER
· FRONT ROOM LAMP
· REAR ROOM LAMP
KEEP RELAY
INTERIOR
LAMP CUT
BACK-UP
CIRCUIT
LOAD
DETERMINATION
CIRCUIT
· ALL DOOR
SWITCH
· FRONT DOOR
SWITCH
· IGNITION
SWITCH (ACC)
· IGNITION
SWITCH (IG1)
· INTERIOR LAMP
LOADED SIGNAL
ETACS-ECU
BATTERY
Interior Lamp Automatic Shut-off Function Circuit