Mitsubishi Outlander (2003+). Manual — part 570
TROUBLESHOOTING
AUTOMATIC AIR CONDITIONER
55B-95
DATA LIST REFERENCE TABLE
M1554005100170
Item No. Check items
Inspection conditions
Normal condition
11
Interior temperature sensor Turn the ignition switch to
the ON position.
Room temperature is the same as
MUT-II/III displayed temperature.
13
Outside thermo sensor
Turn the ignition switch to
the ON position.
Outside temperature is the same as
MUT-II/III displayed temperature.
15
Heater water temperature
sensor
Turn the ignition switch to
the ON position.
Heater core wall surface
temperature is the same as
MUT-II/III displayed temperature.
21
Air thermo sensor
Turn the ignition switch to
the ON position.
Evaporator outlet temperate is the
same as MUT-II/III displayed
temperature
25
Photo sensor
•
Turn the ignition switch to
the ON position.
•
Change the volume of
insolation.
The volume of insolation takes
inverse proportion with the MUT-II/III
displayed voltage.
31
Air mixing damper control
motor and potentiometer
•
Turn the ignition switch to
the ON position.
•
Door position: MAX HOT
Opening angle: approximately
100%
•
Turn the ignition switch to
the ON position.
•
Door position: MAX
COOL
Opening angle: approximately 0%
32
Mode selection damper
control motor and
potentiometer
•
Turn the ignition switch to
the ON position.
•
Damper position: FACE
Opening angle: approximately 0%
•
Turn the ignition switch to
the ON position.
•
Damper position: FOOT
Opening angle: approximately 60%
•
Turn the ignition switch to
the ON position.
•
Damper position:
FOOT/DEF
Opening angle: approximately 80%
•
Turn the ignition switch to
the ON position.
•
Damper position: DEF
Opening angle: approximately
100%
42
A/C pressure sensor
Turn the ignition switch to
the ON position.
A/C refrigerant pressure is the same
as MUT-II/III displayed pressure.
TROUBLESHOOTING
AUTOMATIC AIR CONDITIONER
55B-96
ACTUATOR TEST TABLE
M1554005200166
CHECK AT ENGINE-A/T ECU TERMINALS
M1554005400182
<4G63>
Item No.
Check items
Drive content
01
Blower motor
Stop
02
Low speed
03
Middle speed
04
High speed
05
Air mixing damper control motor
Open angle: Approximately 0% (MAX COOL)
06
Opening angle: approximately 50%
07
Open angle: Approximately 100% (MAX HOT)
08
Mode selection damper control motor FACE
09
FOOT
10
DEF
11
Compressor output
OFF
12
ON
13
outside/inside air selection damper
control motor
Outside air
14
Inside air
38
Idle-up
OFF (A/C high pressure)
39
ON (A/C low pressure)
22
9
16
15
2
14
1
3
19
6
18
17
4 5
20
7
21
8
25
12
23
10
24
11
26
13
JAE-E
34
42
39
31
41
40
3233
37
45
44
43
3536
46
38
JAE-E
79
90
84
8283
72
71
73
JAE-E
87
76
8586
7475
89
88
7778
92
91
8081
AC301466
<C-134>
<C-135>
<C-137>
AB
Terminal
No.
Check items
Check conditions
Normal conditions
8
Output to A/C compressor
A/C compressor relay: OFF
System voltage
A/C compressor relay: ON
0 V
21
Output to fan controller
Air conditioner switch: OFF
4.9
−
5.1 V
Air conditioner switch: ON
0 V
24
Input from A/C-ECU (A/C1) When the A/C is in operation (When the air
thermo sensor detects 3
°
C or more).
System voltage
42
Input from A/C pressure
sensor
2.6MPa
3.9 V
45
Input from A/C-ECU (A/C2) When the A/C is under low load
System voltage
81
A/C pressure sensor power
supply
Always
4.9
−
5.1 V
92
A/C pressure sensor earth
Always
0 V
TROUBLESHOOTING
AUTOMATIC AIR CONDITIONER
55B-97
<4G69>
CHECK AT A/C-ECU TERMINALS
M1554005400159
AC309402
<C-139>
<C-141>
<C-142>
AB
Terminal
No.
Check items
Check conditions
Normal conditions
8
Output to A/C compressor
A/C compressor relay: OFF
System voltage
A/C compressor relay: ON
0 V
17
Output to fan controller
Air conditioner switch: OFF
4.9
−
5.1 V
Air conditioner switch: ON
0 V
69
Input from A/C-ECU (A/C2) When the A/C is under low load
System voltage
78
Input from A/C-ECU (A/C1) When the A/C is in operation (When the air
thermo sensor detects 3
°
C or more).
System voltage
96
A/C pressure sensor earth
Always
0 V
97
A/C pressure sensor power
supply
Always
4.9
−
5.1 V
118
Input from A/C pressure
sensor
2.6MPa
3.9 V
8
2
1
5
3 4
6 7
9 10
20
19
18
17
16
15
14
13
12
11
32
24
29
21
31
30
2223
27
35
33
25
34
26
36
28
AC300196
<C-27>
<C-26>
AB
Terminal
No.
Check items
Check conditions
Normal
conditions
1
Interior temperature sensor
Sensor temperature: 25
°
C (4k
Ω
)
2.1
−
2.7V
2
Output to blower pulse controller
When the blower is operating.
0
−
2.5V (Effective
alternating voltage)
3
Back-up power supply
Always
System voltage
4
Input from heater water
temperature sensor
Sensor temperature: 25
°
C (4k
Ω
)
2.1
−
2.7V
5
Input from air mixing damper
control motor potentiometer
When the damper flaps is moving to
the MAX HOT position.
4.1
−
4.6 V
6
Input from mode selection damper
control motor potentiometer
When the damper is moved to the
DEF position.
4.1
−
4.6 V
7
Input from the outside thermo
sensor
Sensor temperature: 25
°
C (4k
Ω
)
2.1
−
2.7 V
TROUBLESHOOTING
AUTOMATIC AIR CONDITIONER
55B-98
8
Input from the air thermo sensor
Sensor temperature: 25
°
C (4k
Ω
)
2.1
−
2.7 V
9
Photo sensor (-)
Brightness is 0 lux
4.9
−
5.1 V
Brightness is 100000 lux or more
Approximately 0 V
10
Potentiometer power supply
Always
5 V
11
Input from the A/C pressure sensor 2.6 Mpa
3.9 V
12
−
15
-
-
-
16
Rear defogger
When the rear defogger is operating. 2.0 V or less
When the rear defogger is stopped
System voltage
17
Diagnosis set
Ignition switch: ON
A voltmeter needle
fluctuates between
0 and 12 V.
18
Input from diagnosis
Ignition switch: ON
Approximately 5 V
19
Photo sensor (+)
Always
0 V
20
Sensors and potentiometers earth
Always
0 V
21
Air outlet changeover damper
motor (FACE)
When the damper is moved to the
FACE position.
10 V
When the damper is moved to the
DEF position.
Faint voltage (0.5
V)
22
Air mix damper motor (MAX COOL) When the damper flaps is moving to
the MAX COOL position.
10 V
When the damper flaps is moving to
the MAX HOT position.
Faint voltage (0.5
V)
23
outside/inside air selection damper
control motor (outside)
When the damper is moved to the
inside air recirculation position
10 V (When the
motor is stopped)
When the damper is moved to the
outside air inside air intake position
2.0 or less
24
Mode selection damper control
motor and potentiometer (DEF)
When the damper is moved to the
FACE position.
Faint voltage (0.5
V)
When the damper is moved to the
DEF position.
10 V
25
Air mixing damper control motor
and potentiometer (MAX HOT)
When the damper flaps is moving to
the MAX COOL position.
Faint voltage (0.5
V)
When the damper flaps is moving to
the MAX HOT position.
10 V
26
outside/inside air selection damper
control motor (inside)
When the damper is moved to the
inside air recirculation position
2.0 V or less
When the damper is moved to the
outside air inside air intake position
10 V (When the
motor is stopped)
27
Earth
Always
Continuity exists.
28
IG2 power supply
Ignition switch: ON
System voltage
29
Illumination earth
Always
Continuity exists.
30
ILL power supply
Lighting switch: ON
System voltage
31
-
-
-
Terminal
No.
Check items
Check conditions
Normal
conditions