Mitsubishi Grandis. Manual — part 78
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-309
DIAGNOSIS PROCEDURE
Step 1. Check that the headlamps operate.
Do the low-beam headlamps illuminate when the
lighting switch is turned to the HEAD position?
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
First, repair the headlamps. Refer to
Inspection Procedure M-2 "The low-beam
headlamps do not illuminate normally
Step 2. Check the power supply circuit.
When the ignition switch is turned to the LOCK
(OFF) position, check if the hazard warning lamps
illuminate.
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Refer to inspection procedure A-2 "Check
the ETACS-ECU battery power supply
circuit"
.
Step 3. Pulse check
Check the input signals below, which are related to
the daytime running lamp function.
OK: The MUT-III sounds or the voltmeter
needle fluctuates.
Q: Is the check result normal?
YES :
Go to Step 4.
NO :
Refer to inspection procedure Q-2 "The
ignition switch (IG1) signal is not received
Step 4. Connector check: C-221 ETACS-ECU
connector.
Q: Is the check result normal?
YES :
Go to Step 5.
NO :
Repair the defective connector.
Step 5. Resistance measurement at the C-221
ETACS-ECU connector.
(1) Disconnect the connector, and measure at the
wiring harness side.
(2) Check the resistance between the ETACS-ECU
connector and body earth.
• Resistance between C-221 ETACS-ECU
connector terminal No.64 and body earth
OK: 2
Ω or less
Q: Is the check result normal?
YES :
Replace the ETACS-ECU.
NO :
Go to Step 6.
Step 6. Check the wiring harness from C-221
ETACS-ECU connector terminal No.64 to body
earth.
NOTE: Prior to the wiring harness inspection, check
jumper connector C-101, and repair if necessary.
• Check the earth wires for open circuit.
Q: Is the check result normal?
YES :
Replace the ETACS-ECU.
NO :
Repair the wiring harness.
System switch
Check condition
Ignition switch (IG1)
When turned from ACC
to ON
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-310
FLASHER TIMER
Inspection Procedure N-1: The turn-signal lamps do not illuminate.
CAUTION
Whenever the ECU is replaced, ensure that the
input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
If all the turn-signal lamps do not illuminate, the
ignition switch (IG1), the turn-signal lamp switch
input circuit or the ETACS-ECU may be defective.
POSSIBLE CAUSES
• Malfunction of the column switch
• Malfunction of the ETACS-ECU
• Damaged harness wires and connectors
DIAGNOSTIC PROCEDURE
Step 1. Check that the hazard warning lamps
operate.
Check that the hazard warning lamps illuminate
normally.
Q: Is the check result normal?
Wire colour code
B : Black LG : Light green G : Green L : Blue W : White Y : Yellow SB : Sky blue
BR : Brown O : Orange GR : Gray R : Red P : Pink V : Violet
ETACS-ECU
J/B SIDE
RELAY
BOX
TURN-SIGNAL
LAMP RELAY: LH
TURN-SIGNAL
LAMP RELAY: RH
FRONT TURN-SIGNAL
LAMP (LH)
REAR TURN-
SIGNAL LAMP
SIDE TURN-
SIGNAL LAMP
FRONT TURN-
SIGNAL LAMP (RH)
FUSIBLE
LINK
26
Turn-Signal Lamp Power Supply Circuit
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-311
YES :
Go to Step 6.
NO :
Go to Step 2.
Step 2. Connector check: C-219 ETACS-ECU
connector
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Repair the defective connector.
Step 3. Voltage measurement at the C-219
ETACS-ECU connector.
(1) Remove the ETACS-ECU, and measure at the
junction block side.
(2) Voltage between C-219 ETACS-ECU connector
terminal No.11 and body earth
OK: System voltage
Q: Is the check result normal?
YES :
Go to Step 5.
NO :
Go to Step 4.
AC310626
Connector: C-219
Junction block (Rear view)
<LHD>
AB
Junction block side
AC310620
Connector: C-219
Junction block
(Rear view)
<RHD>
AB
Junction block side
AC310626
Connector: C-219
Junction block (Rear view)
<LHD>
AB
Junction block side
AC310620
Connector: C-219
Junction block
(Rear view)
<RHD>
AB
Junction block side
AC310507 BZ
Connector C-219
(Junction block side)
2019
7
13
17
18
1615 14
10
11
12
9 8
2
6 5
3
4
1
SYMPTOM PROCEDURES
SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR
54B-312
Step 4. Check the wiring harness between C-219
ETACS-ECU connector terminal No.11 and the
fusible link (26).
NOTE:
Prior to the wiring harness inspection, check
intermediate connector C-125 and junction block
connector C-203, and repair if necessary.
• Check the power supply line for open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00
− How to
Cope with Intermittent Malfunction
NO :
Repair the wiring harness.
AC310626
Connector: C-219
Junction block (Rear view)
<LHD>
AB
Junction block side
AC310620
Connector: C-219
Junction block
(Rear view)
<RHD>
AB
Junction block side
AC310613
AD
Connector: C-125 <LHD>
AC310628AB
Connector: C-125 <RHD>
AC310623
Connectors: C-203 <LHD>
AL
Harness side
10
1
6
14
5
12
13
4
11
7
2
3
8
9
Junction block (Front view)
AC310618
Connectors: C-203 <RHD>
AK
Harness side
10
1
6
14
5
12
13
4
11
7
2
3
8
9
Junction block (Front view)