Mitsubishi Grandis. Manual — part 552
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54D-306
STEP 2. Resistance measurement at the C-125
intermediate connector.
CAUTION
A digital multimeter should be used. For details
refer to
CAUTION
The test wiring harness should be used. For
details refer to
(1) Disconnect the connector, and measure at its
male-side intermediate connector (at the front
wiring harness side).
(2) Ignition switch: OFF (LOCK)
CAUTION
When measuring the resistance, disconnect the
negative battery terminal. For details refer to
(3) Ensure that the negative battery terminal is
disconnected.
(4) Resistance between C-125 intermediate
connector terminal Nos.26 and 27
OK: 120
± 20 Ω
Q: Is the check result normal?
YES :
<Within 120
± 20 Ω> Go to Step 3 .
NO :
<Not within 120
± 20 Ω> Go to Step 26 .
STEP 3. Connector check: C-09 joint connector
(CAN2)
CAUTION
The strand end of the twist wire should be within
10 cm from the connector. For details refer to
When checking the joint connector, ensure that its
wiring harness side and its short pins are not
damaged.
Q: Is the check result normal?
YES :
Go to Step 4.
NO :
Repair a defective connector or replace the
joint connector.
AC310613
AD
Connector: C-125 <LHD>
AC204740
AC204740
AC204740
AC204740
AC204740DC
Male side: C-125
Test
harness
AC310615
AU
Harness side
Connector: C-09 <LHD>
C-09 (GR)
AC209350
1
12
2
13
3
14
4
15
5
16
6
17
7
18
8
19
9
20
10
21
11
22
AB
Short pin
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54D-307
STEP 4. Resistance measurement at C-09 joint
connector (CAN2).
CAUTION
A digital multimeter should be used. For details
refer to
CAUTION
The test wiring harness should be used. For
details refer to
(1) Disconnect the connector, and measure at the
wiring harness side.
(2) Ignition switch: OFF (LOCK)
CAUTION
When measuring the resistance, disconnect the
negative battery terminal. For details refer to
(3) Ensure that the negative battery terminal is
disconnected.
(4) Resistance between C-09 joint connector (CAN2)
terminal Nos. 7 and 18
OK: 120
± 20 Ω
(5) Resistance between C-09 joint connector (CAN2)
terminal Nos. 2 and 13
OK: 1 k
Ω or more
(6) Resistance between C-09 joint connector (CAN2)
AC310615
AU
Harness side
Connector: C-09 <LHD>
C-09 (GR)
AC204740DD
Harness side: C-09
Test
harness
Test
harness
AC204740DE
Harness side: C-09
Test
harness
Test
harness
AC204740DF
Harness side: C-09
Test
harness
Test
harness
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54D-308
terminal Nos. 3 and 14
OK: 1 k
Ω or more
(7) Resistance between C-09 joint connector (CAN2)
terminal Nos. 5 and 16
OK: 1 k
Ω or more
(8) Resistance between C-09 joint connector (CAN2)
terminal Nos. 1 and 12
OK: 1 k
Ω or more
(9) Resistance between C-09 joint connector (CAN2)
terminal Nos. 6 and 17
OK: 1 k
Ω or more
Q: Are the check result normal?
YES <all of the measurement results are within the
normal value> :
Go to Step 25.
NO <The resistance between terminal Nos. 7 and
18 is less than 120
±20 Ω> :
Go to Step 5.
NO <The resistance between terminal Nos. 2 and
13 is less than 1 k
Ω> :
Go to Step 8.
NO <The resistance between terminal Nos. 3 and
14 is less than 1 k
Ω> :
Go to Step 11.
NO <The resistance between terminal Nos. 5 and
16 is less than 1 k
Ω> :
Go to Step 14.
NO <The resistance between terminal Nos. 1 and
12 is less than 1 k
Ω> :
Go to Step 20.
NO <The resistance between terminal Nos. 6 and
17 is less than 1 k
Ω> :
Go to Step 23.
AC204740DG
Harness side: C-09
Test
harness
Test
harness
AC204740DH
Harness side: C-09
Test
harness
Test
harness
AC204740DI
Harness side: C-09
Test
harness
Test
harness
DIAGNOSIS
CONTROLLER AREA NETWORK (CAN)
54D-309
STEP 5. Connector check: C-02 combination
meter connector
CAUTION
The strand end of the twist wire should be within
10 cm from the connector. For details refer to
Q: Is the check result normal?
YES :
Go to Step 6.
NO :
Repair the defective connector.
STEP 6. Resistance measurement at C-09 joint
connector (CAN2).
CAUTION
A digital multimeter should be used. For details
refer to
CAUTION
The test wiring harness should be used. For
details refer to
(1) Disconnect the joint connector (CAN2) and the
combination meter connector, and measure at
the wiring harness side.
(2) Ignition switch: OFF (LOCK)
CAUTION
When measuring the resistance, disconnect the
negative battery terminal. For details refer to
(3) Ensure that the negative battery terminal is
disconnected.
(4) Continuity between C-09 joint connector (CAN2)
terminal Nos. 7 and 18
OK: More than 2
Ω
CAUTION
Strictly observe the specified wiring harness
repair procedure. For details refer to
Q: Is the check result normal?
YES :
<More than 2
Ω> Go to Step 7.
NO :
<2
Ω or less> Repair the wiring harness
between joint connector (CAN2) and the
combination meter connector.
AC310613
BB
Connector: C-02 <LHD>
Harness side
AC310613
BB
Connector: C-02 <LHD>
Harness side
AC310615
AU
Harness side
Connector: C-09 <LHD>
C-09 (GR)
AC204740DD
Harness side: C-09
Test
harness
Test
harness
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.