Mitsubishi Grandis. Manual — part 937
TROUBLESHOOTING
TRACTION CONTROL/ACTIVE STABILITY CONTROL SYSTEM
35C-73
DIAGNOSIS
STEP 1. MUT-III CAN bus diagnostics
CAUTION
Before connecting or disconnecting the MUT-III,
turn the ignition switch to the "LOCK" (OFF)
position.
(1) Connect MUT-III to the 16-pin diagnosis
connector.
(2) Turn the ignition switch to the "ON" position.
(3) Diagnose the CAN bus line.
(4) Turn the ignition switch to the "LOCK" (OFF)
position.
Q: Is the check result normal?
YES :
Go to Step 3.
NO :
Repair the CAN bus line (Refer to GROUP
54D, CAN bus line Diagnostic flow
). Then go to Step 2.
STEP 2. Check whether the diagnosis code is
reset.
CAUTION
Before connecting or disconnecting the MUT-III,
turn the ignition switch to the "LOCK" (OFF)
position.
(1) Turn the ignition switch to the "ON" position.
(2) Erase the diagnosis code.
(3) Turn the ignition switch to the "LOCK" (OFF)
position.
(4) Turn the ignition switch to the "ON" position.
(5) Check if the diagnosis code is set.
(6) Turn the ignition switch to the "LOCK" (OFF)
position.
Q: Is code No.C1377 set?
YES :
Go to Step 3.
NO :
The procedure is complete.
STEP 3. Voltage measurement at G and yaw rate
sensor connector C-117.
AC302297
AC310120
AB
MB991827
16-pin
MB991910
MB991824
AC302297
AC310120
AB
MB991827
16-pin
MB991910
MB991824
TROUBLESHOOTING
TRACTION CONTROL/ACTIVE STABILITY CONTROL SYSTEM
35C-74
(1) Disconnect TCL/ASC-ECU connector A-04 and
G and yaw rate sensor connector C-117
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between the relevant signal
terminals 2, 3 and earth.
OK: Less than 1V
Q: Is the check result normal?
YES :
Go to Step 4.
NO :
Check the harness wire between
TCL/ASC-ECU and the G and yaw rate
sensor for short to power supply. Repair if
necessary, and then go to Step 8.
AC312621
Oil reservoir
Connector: A-04
AB
A-04
Hydraulic unit
(with built-in TCL/ASC-ECU)
A-04 Harness connector
(harness side)
AC313186
AD
Connector: C-117
<L.H.drive vehicles>
C-117
C-117 Harness connector
(harness side)
AC313188
C-117 Harness connector
(harness side)
AD
Connector: C-117
<R.H.drive vehicles>
C-117
TROUBLESHOOTING
TRACTION CONTROL/ACTIVE STABILITY CONTROL SYSTEM
35C-75
STEP 4. Resistance measurement at G and yaw
rate sensor connector C-117.
TROUBLESHOOTING
TRACTION CONTROL/ACTIVE STABILITY CONTROL SYSTEM
35C-76
(1) Disconnect TCL/ASC-ECU connector A-04 and
G and yaw rate sensor connector C-117
(2) Turn the ignition switch to the "ON" position.
(3) Measure the resistance between the relevant
signal terminals 2, 3 and earth.
OK: No continuity
Q: Is the check result normal?
YES :
Go to Step 5.
NO :
Check the harness wire between
TCL/ASC-ECU and the G and yaw rate
sensor for short to earth. Repair if
necessary, and then go to Step 8.
AC312621
Oil reservoir
Connector: A-04
AB
A-04
Hydraulic unit
(with built-in TCL/ASC-ECU)
A-04 Harness connector
(harness side)
AC313186
AE
Connector: C-117
<L.H.drive vehicles>
C-117
C-117 Harness connector
(harness side)
AC313188
C-117 Harness connector
(harness side)
AE
Connector: C-117
<R.H.drive vehicles>
C-117
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.