Mitsubishi Montero Sport (2004+). Manual — part 169
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI)
13A-89
DTC P0111: Intake Air Temperature Circuit Range/Performance Problem
AK301863
Intake Air Temperature Sensor Circuit
RED
-BL
UE
BL
ACK
BL
ACK
57
5
5V
POWERTRAIN CONTROL MODULE (PCM)
INTAKE AIR TEMPERATURE SENSOR
(INCORPORATED IN VOLUME
AIRFLOW SENSOR)
12
6
64
15
1 2 3 4 5 6 7
A-01
1
10
2 3 4 5 6 7 8 9
11
12 13 14 15 16 17 18 19 20 21 22
23 24 25 26 27 28 29 30 31 32 33
C-71
47
41
42 43
48 49 50 51 52 53 54 55 56 57
46
45
44
58
59
60 61 62 63
64 65 66
C-90
(MU803781)
JOINT
CONNEC-
TOR (4)
AK103908
CONNECTOR: A-01
INTAKE AIR
TEMPERATURE
SENSOR
A-01(B)
AD
AK103912AB
CONNECTOR: C-71
C-71
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI)
13A-90
.
CIRCUIT OPERATION
• Approximately 5 volts are applied to the intake air
temperature sensor output terminal (terminal No.
6) from the PCM (terminal No. 64) via the resistor
in the PCM. The ground terminal (terminal No. 5)
is grounded with PCM (terminal No. 57).
• The intake air temperature sensor is a negative
temperature coefficient type of resistor. When the
intake air temperature rises, the resistance
decreases.
• The intake air temperature sensor output voltage
increases when the resistance increases and
decreases when the resistance decreases.
.
TECHNICAL DESCRIPTION
• The intake air temperature sensor converts the
intake air temperature to a voltage.
• The PCM checks whether this voltage is within a
specified range.
.
DESCRIPTIONS OF MONITOR METHODS
Intake air temperature sensor output voltage does
not change when specified go/stop operations
are repeated.
.
MONITOR EXECUTION
Continuous
.
MONITOR EXECUTION CONDITIONS (Other
monitor and Sensor)
Other Monitor (There is no temporary DTC stored
in memory for the item monitored below)
• Not applicable
Sensor (The sensor below is determined to be
normal)
• Not applicable
.
AK103738AC
CONNECTOR: C-90
PCM
C-90(GR)
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI)
13A-91
DTC SET CONDITIONS
Logic Flow Chart
.
Check Conditions
• Engine coolant temperature is higher than 76°C
(169
°F).
• Repeat 5 or more times: drive
*1
, stop
*2
.
Drive
*1
: vehicle speed higher than 50 km/h (31
mph) lasting a total of more than 60 seconds.
Stop
*2
: vehicle speed lower than 1.5 km/h (0.9
mph) lasting more than 30 seconds.
Judgement Criteria
• Changes in the intake air temperature is lower
than 1
°C (1.8°F).
.
OBD-II DRIVE CYCLE PATTERN
Refer to Diagnostic Function
− OBD-II Drive Cycle −
Procedure 6
.
.
TROUBLESHOOTING HINTS (The most likely
causes for this code to be set are:)
• Intake air temperature sensor failed.
• Harness damage in intake air temperature sensor
circuit, or connector damage.
• PCM failed.
END
YES
NO
NO
NO
START
MONITORING
CONDITION
YES
MALFUNCTION
GOOD
F1: COUNTER OF A DRIVING STATE.
F2: COUNTER OF A STOP STATE.
INTAKE AIR TEMP.
CHANGES
GO/STOP OPERATION
FOR SPECIFIED TIMES
YES
AK301423
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI)
13A-92
DIAGNOSIS
Required Special Tools:
• MB991958: Scan Tool (MUT-III Sub Assembly)
• MB991824: V.C.I
• MB991827: USB Cable
• MB991911: Main Harness B
STEP 1. Using scan tool MB991958, check data list item 13:
Intake Air Temperature Sensor.
CAUTION
To prevent damage to scan tool MB991958, always turn the
ignition switch to the "LOCK" (OFF) position before con-
necting or disconnecting scan tool MB991958.
(1) Connect scan tool MB991958 to the data link connector.
(2) Remove the air intake hose from the volume airflow sensor.
(3) Turn the ignition switch to the "ON" position.
(4) Set scan tool MB991958 to the data reading mode for item
13, Intake Air Temperature Sensor.
(5) Heating the sensor using a hair drier.
• The indicated temperature increases.
NOTE: Do not allow it to increase over 80
°
C (176
°
F).
(6) Turn the ignition switch to the "LOCK" (OFF) position.
(7) Attach the air intake hose.
Q: Is the sensor operating properly?
YES : It can be assumed that this malfunction is intermittent.
Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
NO : Go to Step 2.
AK303629AB
MB991911
MB991827
MB991824
16-PIN
AKX01621 AB
INTAKE AIR
TEMPERATURE
SENSOR
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.