Mitsubishi Montero Sport (2004+). Manual — part 597
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-15
STEP 2. Check the blower relay continuity.
Q: Is there continuity at the blower relay?
YES : Go to Step 3.
NO : Replace. Then go to Step 4.
STEP 3. Check the blower switch continuity.
Q: Is there continuity at the blower switch?
YES : Go to Step 4.
NO : Replace. Then go to Step 4.
BATTERY
CONNECTION
TESTER
CONNECTION
SPECIFIED
CONDITION
Not applied
4
− 5
Open circuit
• Connect
terminal 3 to the
positive battery
terminal
• Connect
terminal 1 to the
negative battery
terminal
4
− 5
Less than 2 ohms
AC002841AB
BLOWER
RELAY
SWITCH
POSITION
TESTER
CONNECTION
SPECIFIED
CONDITION
OFF
1
− 8
2
− 5
3
− 5
5
− 6
5
− 7
Open circuit
LO
3
− 5
1
− 8
Less than 2 ohms
ML
5
− 6
1
− 8
Less than 2 ohms
MH
2
− 5
1
− 8
Less than 2 ohms
HI
5
− 7
1
− 8
Less than 2 ohms
AC002851AB
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-16
STEP 4. Retest the system.
Q: Does the blower motor stop operating?
YES : The procedure is complete. (If no malfunctions are
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
.)
NO : Go to Step 1.
INSPECTION PROCEDURE 6: When the A/C is Operating, Condenser Fan do not Operate.
DIAGNOSIS
STEP 1. Check the condensor fan control Relay continuity.
Remove the condensor fan control Relay and check continuity.
Q: Is there continuity at the condensor fan control Relay?
YES : Go to Step 2.
NO : Replace. Then go to Step 4.
BATTERY
CONNECTION
TESTER
CONNECTION
SPECIFIED
CONDITION
Not applied
4
− 5
Open circuit
• Connect
terminal 3 to the
positive battery
terminal
• Connect
terminal 1 to the
negative battery
terminal
4
− 5
Less than 2 ohms
AC002843 AB
CONDENSER FAN
MOTOR RELAY
A/C
COMPRESSOR
RELAY
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-17
STEP 2. Check the condenser fan motor operation.
Remove the condenser fan motor and check continuity.
Q: Is the condenser fan motor operating correctly?
YES : Go to Step 3.
NO : Replace. Then go to Step 3.
STEP 3. Measure the PCM terminal voltage.
Refer to GROUP 13A, Check at PCM terminals
.
Q: Is the PCM voltage correct?
YES : Go to Step 4.
NO : Replace. Then go to Step 4.
STEP 4. Retest the system.
NOTE: The condenser fan might not operate when there is an
air conditioning low load from the air conditioning condenser
control, so remove the negative battery terminal and then
check the symptoms after 5 minutes since initial start control
after reconnection.
Q: Is the condenser fan operating correctly?
YES : The procedure is complete. (If no malfunctions are
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
.)
NO : Go to Step 1.
BATTERY CONNECTION
MOTOR OPERATION
• Connect terminal 2 to the positive
battery terminal
• Connect terminal 1 to the
negative battery terminal
Rotates
AC002870AB
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-18
INSPECTION PROCEDURE 7: Even when the Rear Heater Switch is Pressed, the Blower Fan does not
Turn.
DIAGNOSIS
STEP 1. Check the rear heater relay continuity.
Remove the rear heater relay and check continuity.
Q: Is there continuity at the rear heater relay?
YES : Go to Step 2.
NO : Replace. Then go to Step 5.
STEP 2. Check the rear blower motor operation.
When battery voltage is applied between the terminals, check
that the motor operates. Also, check that there is no abnormal
noise.
Q: Is the rear blower motor operating correctly?
YES : Go to Step 3.
NO : Replace. Then go to Step 5.
BATTERY
CONNECTION
TESTER
CONNECTION
SPECIFIED
CONDITION
Not applied
4
− 5
Open circuit
• Connect
terminal 3 to the
positive battery
terminal
• Connect
terminal 1 to the
negative battery
terminal
4
− 5
Less than 2 ohms
AC002844 AB
REAR HEATER RELAY
BATTERY CONNECTION SPECIFIED CONDITION
• Connect terminal 1 to
the positive battery
terminal
• Connect terminal 3 to
the negative battery
terminal
Blower motor rotates (HI)
• Connect terminal 1 to
the positive battery
terminal
• Connect terminal 4 to
the negative battery
terminal
Blower motor rotates (LO)
AC002863AB
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.