Mitsubishi Montero Sport (2004+). Manual — part 598
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-19
STEP 3. Check the rear heater switch continuity.
Remove the rear heater switch and check continuity.
Q: Is the rear heater switch normal?
YES : Go to Step 4.
NO : Replace. Then go to Step 5.
STEP 4. Check the resister resistance value.
Use an ohmmeter to check the resistance between terminals
number 3 and 4. Check that the measured value is at the stan-
dard value.
Standard value: 3.9
Ω
Q: Is the resistance value correct?
YES : The procedure is complete. (If no malfunctions are
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
.)
NO : Replace. Then go to Step 5.
STEP 5. Retest the system.
NOTE: The condenser fan might not operate when there is an
air conditioning low load from the air conditioning condenser
control, so remove the negative battery terminal and then
check the symptoms after 5 minutes since initial start control
after reconnection.
Q: Is the condenser fan operating correctly?
YES : The procedure is complete.
NO : Go to Step 1.
SWITCH
POSITION
TESTER
CONNECTION
SPECIFIED
CONDITION
At the "OFF"
position
1
− 4
2
− 4
Open circuit
At the "LO"
position
2
− 4
Less than 2 ohms
At the "HI"
position
1
− 4
Less than 2 ohms
AC002861
LO
OFF
HI
AC
AC002863AB
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-20
INSPECTION PROCEDURE 8: The Rear Heater Air Volume cannot be Controlled in Two Steps.
DIAGNOSIS
STEP 1. Check the rear heater switch continuity.
Remove the rear heater switch and check continuity.
Q: Is the rear heater switch normal?
YES : Go to Step 2.
NO : Replace. Then go to Step 3.
STEP 2. Check the resister resistance value.
Use an ohmmeter to check the resistance between terminals
number 3 and 4. Check that the measured value is at the stan-
dard value.
Standard value: 3.9
Ω
Q: Is the resistance value correct?
YES : The procedure is complete. (If no malfunctions are
found in all steps, an intermittent malfunction is
suspected. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
.)
NO : Replace. Then go to Step 3.
STEP 3. Retest the system.
NOTE: The condenser fan might not operate when there is an
air conditioning low load from the air conditioning condenser
control, so remove the negative battery terminal and then
check the symptoms after 5 minutes since initial start control
after reconnection.
Q: Is the condenser fan operating correctly?
YES : The procedure is complete.
NO : Go to Step 1.
SWITCH
POSITION
TESTER
CONNECTION
SPECIFIED
CONDITION
At the "OFF"
position
1
− 4
2
− 4
Open circuit
At the "LO"
position
2
− 4
Less than 2 ohms
At the "HI"
position
1
− 4
Less than 2 ohms
AC002861
LO
OFF
HI
AC
AC002863AB
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-21
INSPACTION PROCEDURE 9: When the Heater Control Knob is Set to the "MAX COOL" Position, the
Air-Conditioning does not Cool Sufficiently.
DIAGNOSIS
STEP 1. Check for refrigerant leaks.
Q: Is the refrigerant leaking?
YES : Repair. Then go to Step 4.
NO : Go to Step 2.
STEP 2. Check the water shut motor
CAUTION
When the motor stops, disconnect battery cable.
Follow the table below to check the water shut motor for correct
operation.
Q: Does water shut motor work normally?
YES : Go to Step 3.
NO : Replace. Then go to Step 4.
STEP 3. Check the water shut valve controller continuity.
NOTE: When the temperature control knob is at the "MAX
COOL" position, power is supplied to the water shut relay.
LEVER POSITION BATTERY
CONNECTION
LEVER
OPERATION
At the open position
• Connect
terminal 3 to the
positive battery
terminal
• Connect
terminal 1 to the
negative battery
terminal
The lever moves
from the open
position to the
closed position
At the close
position
• Connect
terminal 3 to the
positive battery
terminal
• Connect
terminal 2 to the
negative battery
terminal
The lever moves
from the closed
position to the open
position
AC306351AB
OPEN
SIDE
CLOSE
SIDDE
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55-22
Follow the table below to check the water shut valve controller
for continuity.
Q: Is the water shut valve controller in good condition?
YES : Go to Step 4.
NO : Replace. Then go to Step 4.
STEP 4. Check symptoms.
Q: Is the cool air discharged?
YES : This diagnosis is complete. (If no malfunctions are not
found in all steps, an intermittent malfunction is
suspected. Refer to Introduction, How to Use
Troubleshooting/Inspection Service Points
− How to
Cope with Intermittent Malfunction
.)
NO : Go to Step 1.
TEMPERATURE
CONTROL KNOB
POSITION
BATTERY CONNECTION TESTER
CONNECTION
SPECIFIED
CONDITION
At the "MAX
COOL" position
• Connect
terminal 7 to
the positive
battery
terminal
• Connect
terminal 3 to
the negative
battery
terminal
3
− 8
Less than 2
ohms
At the other than
"MAX COOL"
position
• Connect
terminal 7 to
the positive
battery
terminal
• Connect
terminal 3 to
the negative
battery
terminal
1
− 3
Less than 2
ohms
AC002849
DEFROSTER
SWITCH
AB
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст