Mitsubishi Montero (2002-2004). Manual — part 349
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-443
STEP 15. Check the ground circuit to the fog light indicator
light. Test at combination meter connector D-03.
(1) Disconnect fog light indicator light connector D-03 and
measure the resistance available at the wiring harness side
of the connector.
(2) Measure the resistance value between terminal 57 and
ground.
• The resistance should equal 2 ohms or less.
Q: Is the measured resistance 2 ohms or less?
YES : Go to Step 18.
NO : Go to Step 16.
STEP 16. Check combination meter connector D-03 for
loose, corroded or damaged terminals, or terminals
pushed back in the connector.
Q: Is combination meter connector D-03 in good
condition?
YES : Go to Step 17.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
. Verify that the fog light indicator light
illuminates normally.
AC204170
CONNECTOR : D-03
AC
D-03(GR)
HARNESS
SIDE
51
52
61 60
53
54
56
57
55
63
66 65 64
59
62
58
67
D-03(GR)
61
62
63
64
65
66
57
58
59
60
51
52
53
54
55
56
67
AC100271AB
CONNECTOR D-03
(HARNESS SIDE)
AC204170
CONNECTOR : D-03
AC
D-03(GR)
HARNESS
SIDE
51
52
61 60
53
54
56
57
55
63
66 65 64
59
62
58
67
D-03(GR)
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-444
STEP 17. Check the wiring harness between combination
meter connector D-03 (terminal 57) and ground.
NOTE: Also check joint connector D-30 for loose, corroded, or
damaged terminals, or terminals pushed back in the connector.
If joint connector D-30 is damaged, repair or replace the dam-
aged component(s) as described in GROUP 00E, Harness
Connector Inspection
.
Q: Is the wiring harness between combination meter
connector D-03 (terminal 57) and ground in good
condition?
YES : No action is necessary and testing is complete.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that
the fog light indicator light illuminates normally.
STEP 18. Check combination meter connector D-04 for
loose, corroded or damaged terminals, or terminals
pushed back in the connector.
Q: Is combination meter connector D-04 in good
condition?
YES : Go to Step 19.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
. Verify that the fog light indicator light
illuminates normally.
AC204188
CONNECTORS : D-03, D-30
D-30
AI
HARNESS SIDE
D-03(GR)
D-30
D-03(GR)
9 10
8
6 7
31 32
30
29
18 19 20 21
5
4
2
1
3
27
26
24
23
25
12 13 14 15 16 17
28
11
22
33
51
52
61 60
53
54
56
57
55
63
66 65 64
59
62
58
67
AC204183
CONNECTOR : A-13X
RELAY BOX SIDE
AF
2 1
5
4
3
A-13X
AC204170
CONNECTOR : D-04
AD
D-04(GR)
HARNESS
SIDE
D-04(GR)
31
32
41 40
33
34
36
37
35
43
46 45 44
39
42
38
47
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-445
STEP 19. Check the wiring harness between relay box
(fuse No.20) and combination meter connector D-04
(terminal 42).
NOTE: Also check intermediate connector D-28 for loose, cor-
roded, or damaged terminals, or terminals pushed back in the
connector. If intermediate connector D-28 is damaged, repair or
replace the damaged component(s) as described in GROUP
00E, Harness Connector Inspection
Q: Is the wiring harness between relay box (fuse No.20)
and combination meter connector D-04 (terminal 42) in
good condition?
YES : Replace the combination meter (printed-circuit
board). Verify that the fog light indicator light
illuminates normally.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that
the fog light indicator light illuminates normally.
STEP 20.Check the ground circuit to the fog light (LH). Test
at fog light (LH) connector A-21.
(1) Disconnect fog light (LH) connector A-21 and measure the
resistance available at the wiring harness side of the
connector.
(2) Measure the resistance value between terminal 2 and
ground.
• The resistance should equal 2 ohms or less.
Q: Is the measured resistance 2 ohms or less?
YES : Go to Step 22.
NO : Go to Step 21.
AC204188
CONNECTORS : D-04, D-28
D-04(GR)
AK
HARNESS SIDE
D-04(GR)
D-28
D-28
31
32
41 40
33
34
36
37
35
43
46 45 44
39
42
38
47
2 3
27
32
28
33
16
15
4 5
19
18
29
17
34
7 8
35
22
21
9 10
30
36
31
37
25
24
23
6
20
1
14
26
11
13
12
38
AC204167
CONNECTOR : A-21
HARNESS
SIDE
A-21(B)
A-21(B)
AJ
1
2
AC100270
1
2
AB
CONNECTOR A-21
(HARNESS SIDE)
SYMPTOM PROCEDURES
TSB Revision
SWS SYMPTOM PROCEDURES
54Bb-446
STEP 21. Check the wiring harness between fog light (LH)
connector A-21 (terminal 2) and ground.
NOTE: Also check intermediate connector A-25 for loose, cor-
roded, or damaged terminals, or terminals pushed back in the
connector. If intermediate connector A-25 is damaged, repair or
replace the damaged component(s) as described in GROUP
00E, Harness Connector Inspection
Q: Is the wiring harness between fog light (LH) connector
A-21 (terminal 2) and ground in good condition?
YES : No action is necessary and testing is complete.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that
the fog lights illuminate normally.
STEP 22. Check joint connector (2) A-15 for loose,
corroded or damaged terminals, or terminals pushed back
in the connector.
Q: Is joint connector (2) A-15 in good condition?
YES : Go to Step 23.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
. Verify that the fog lights illuminate normally.
STEP 23. Check the wiring harness between joint
connector (2) A-15 (terminal 1) and relay box (fuse No. 20).
Q: Is the wiring harness between joint connector (2) A-15
(terminal 1) and relay box (fuse No. 20) in good
condition?
YES : No action is necessary and testing is complete.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that
the fog lights illuminate normally.
AC204185
CONNECTORS : A-21, A-25
A-21(B)
A-25(B)
AF
A-25(B)
HARNESS SIDE
A-21(B)
1
2
4
2
3
1
AC204167
CONNECTOR : A-15
AD
14
13
4
1112
5
3
10
8 9
2
7
1
6
AC204167
CONNECTOR : A-15
AD
14
13
4
1112
5
3
10
8 9
2
7
1
6
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст