Mitsubishi Galant. Manual — part 420
AUTOMATIC TRANSAXLE DIAGNOSIS
TSB Revision
AUTOMATIC TRANSAXLE
23A-147
STEP 7. Check the switch output voltage at PCM
connector C-42 by backprobing. ("D" position)
Measure the voltage between terminal 102 and ground by
backprobing.
•
When selector lever position is "P," voltage should be 0.5
volt or less.
•
When selector lever position is "R," voltage should be 0.5
volt or less.
•
When selector lever position is "N," voltage should be 0.5
volt or less.
•
When selector lever position is "D," voltage should be
battery positive voltage.
•
When selector lever position is "3," voltage should be 0.5
volt or less.
•
When selector lever position is "2," voltage should be 0.5
volt or less.
•
When selector lever position is "L," voltage should be 0.5
volt or less.
Q: Is the voltage normal?
YES : Go to Step 8.
NO : Turn the ignition switch to "LOCK" (OFF) position.
Repair it because of the harness damage between
the Park/Neutral position switch connector B-39
terminal 1 and PCM connector C-42 terminal 102.
STEP 8. Check the switch output voltage at PCM
connector C-42 by backprobing. ("3" position)
Measure the voltage between terminal 109 and ground by
backprobing.
•
When selector lever position is "P," voltage should be 0.5
volt or less.
•
When selector lever position is "R," voltage should be 0.5
volt or less.
•
When selector lever position is "N," voltage should be 0.5
volt or less.
•
When selector lever position is "D," voltage should be 0.5
volt or less.
•
When selector lever position is "3," voltage should be
battery positive voltage.
•
When selector lever position is "2," voltage should be 0.5
volt or less.
•
When selector lever position is "L," voltage should be 0.5
volt or less.
Q: Is the voltage normal?
YES : Go to Step 9.
NO : Turn the ignition switch to "LOCK" (OFF) position.
Repair it because of the harness damage between
the Park/Neutral position switch connector B-39
terminal 5 and PCM connector C-42 terminal 109.
AC001906
C-42 CONNECTOR
HARNESS SIDE VIEW
AE
AC001907
C-42 CONNECTOR
HARNESS SIDE VIEW
AE
AUTOMATIC TRANSAXLE DIAGNOSIS
TSB Revision
AUTOMATIC TRANSAXLE
23A-148
STEP 9. Check the switch output voltage at PCM
connector C-42 by backprobing. ("2" position)
Measure the voltage between terminal 122 and ground by
backprobing.
•
When selector lever position is "P," voltage should be 0.5
volt or less.
•
When selector lever position is "R," voltage should be 0.5
volt or less.
•
When selector lever position is "N," voltage should be 0.5
volt or less.
•
When selector lever position is "D," voltage should be 0.5
volt or less.
•
When selector lever position is "3," voltage should be 0.5
volt or less.
•
When selector lever position is "2," voltage should be
battery positive voltage.
•
When selector lever position is "L," voltage should be 0.5
volt or less.
Q: Is the voltage normal?
YES : Go to Step 10.
NO : Turn the ignition switch to "LOCK" (OFF) position.
Repair it because of the harness damage between
the Park/Neutral position switch connector B-39
terminal 2 and PCM connector C-42 terminal 122.
STEP 10. Check the switch output voltage at PCM
connector C-42 by backprobing. ("L" position)
Measure the voltage between terminal 110 and ground by
backprobing.
•
When selector lever position is "P," voltage should be 0.5
volt or less.
•
When selector lever position is "R," voltage should be 0.5
volt or less.
•
When selector lever position is "N," voltage should be 0.5
volt or less.
•
When selector lever position is "D," voltage should be 0.5
volt or less.
•
When selector lever position is "3," voltage should be 0.5
volt or less.
•
When selector lever position is "2," voltage should be 0.5
volt or less.
•
When selector lever position is "L," voltage should be
battery positive voltage.
Q: Is the voltage normal?
YES : Go to Step 11.
NO : Turn the ignition switch to "LOCK" (OFF) position.
Repair it because of the harness damage between
the Park/Neutral position switch connector B-39
terminal 6 and PCM connector C-42 terminal 110.
AC001908
C-42 CONNECTOR
HARNESS SIDE VIEW
AE
AC001946
C-42 CONNECTOR
HARNESS SIDE VIEW
AE
AUTOMATIC TRANSAXLE DIAGNOSIS
TSB Revision
AUTOMATIC TRANSAXLE
23A-149
STEP 11. Using scan tool MB991502, check data list item
61: Park/Neutral Position Switch.
CAUTION
To prevent damage to scan tool MB991502, always turn the
ignition switch to "LOCK" (OFF) position before
connecting or disconnecting scan tool MB991502.
(1) Connect scan tool MB991502 to the data link connector.
(2) Turn the ignition switch to "ON" position.
(3) Set scan tool MB991502 to data reading mode for item 61:
Park/Neutral Position Switch.
•
Move the selector lever to "P," "R," "N," "D," "3," "2," "L"
positions to confirm whether the MUT-II.
(4) Turn the ignition switch to "LOCK" (OFF) position.
Q: Is the switch operating properly?
YES : This malfunction is intermittent. Refer to GROUP 00,
How to Use Troubleshooting/Inspection Service
Points
−
How to Cope with Intermittent Malfunction
NO : Replace the PCM.
AC003081AC
MB991502
DATA LINK
CONNECTOR
AUTOMATIC TRANSAXLE DIAGNOSIS
TSB Revision
AUTOMATIC TRANSAXLE
23A-150
DTC 29: Vehicle Speed Sensor System
AC004617
Vehicle Speed Sensor System Circuit
AB
AC004308AB
CONNECTOR: C-17
AC004287
CONNECTOR: C-30
AE