Mitsubishi Galant. Manual — part 711
SWS DIAGNOSIS
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-239
STEP 5. Check the harness wires between power window
main switch connector E-16 and ground.
NOTE: After checking intermediate connector C-68, check the
wires. If intermediate connector C-68 is damaged, repair or
replace it. Refer to GROUP 00E, Harness Connector
Inspection.
Q: Are the harness wires between power window main
switch connector E-16 and ground in good condition?
YES : There is no action to be taken.
NO : Repair them. The door lock switch input signal should
be able to be checked and the central door locking
system should work normally.
STEP 6. Check the power window main switch connector
E-16 and ETACS-ECU connector C-81 for damage.
Q: Are power window main switch connector E-16 and
ETACS-ECU connector C-81 in good condition?
YES : Go to Step 7.
NO : Repair or replace them. Refer to GROUP 00E,
Harness Connector Inspection
lock switch input signal should be able to be checked
and the central door locking system should work
normally.
AC003086AM
DOOR
CONNECTOR: E-16
AC003079AK
CONNECTOR
BLOCK (LH)
CONNECTOR: C-68
AC003082 AJ
JUNCTION BLOCK
(FRONT VIEW)
CONNECTOR: C-81
AC003086AM
DOOR
CONNECTOR: E-16
SWS DIAGNOSIS
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-240
STEP 7. Check the harness wires between power window
main switch connector E-16 and ETACS-ECU connector C-
81.
NOTE: After checking intermediate connector C-68, check the
wires. If intermediate connector C-68 is damaged, repair or
replace it. Refer to GROUP 00E, Harness Connector
Inspection
.
Q: Are the harness wires between power window main
switch connector E-16 and ETACS-ECU connector C-81
in good condition?
YES : Replace the ETACS-ECU. The door lock switch input
signal should be able to be checked and the central
door locking system should work normally.
NO : Repair them. The door lock switch input signal should
be able to be checked and the central door locking
system should work normally.
STEP 8. Check the door lock switch (power window sub
switch).
Q: Is the door lock switch (power window sub switch) in
good condition?
YES : Go to Step 9.
NO : Replace the power window sub switch. The door lock
switch input signal should be able to be checked and
the central door locking system should work normally.
AC003082 AJ
JUNCTION BLOCK
(FRONT VIEW)
CONNECTOR: C-81
AC003086AM
DOOR
CONNECTOR: E-16
AC003079AK
CONNECTOR
BLOCK (LH)
CONNECTOR: C-68
SWITCH POSI-
TION
TESTER CON-
NECTION
SPECIFIED
CONDITION
LOCK
1
−
2
Continuity
OFF
−
No continuity
UNLOCK
2
−
3
Continuity
AC003182
SWS DIAGNOSIS
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-241
STEP 9. Check the power window sub switch ground
circuit at power window sub switch connector E-05.
(1)Disconnect power window sub switch connector E-05 and
measure at the harness side.
(2)Measure the resistance between terminal 2 and ground.
Q: Is the resistance less than 2 ohm?
YES : Go to Step 12.
NO : Go to Step 10.
STEP 10. Check power window sub switch connector E-05
for damage.
Q: Is power window sub switch connector E-05 in good
condition?
YES : Go to Step 11.
NO : Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection
input signal should be able to be checked and the
central door locking system should work normally.
STEP 11. Check the harness wires between power window
sub switch connector E-05 and ground.
NOTE: After checking intermediate connector C-72, check the
wires. If intermediate connector C-72 is damaged, repair or
replace it. Refer to GROUP 00E, Harness Connector
Inspection.
Q: Are the harness wires between power window sub
switch connector E-05 and ground in good condition?
YES : There is no action to be taken.
NO : Repair them. The door lock switch input signal should
be able to be checked and the central door locking
system should work normally.
AC003423 AB
CONNECTOR E-05
(HARNESS SIDE)
AC003086 AN
DOOR
CONNECTOR: E-05
AC003086 AN
DOOR
CONNECTOR: E-05
AC003415 AD
CONNECTOR: C-72
CONNECTOR
BLOCK (RH)
SWS DIAGNOSIS
TSB Revision
SIMPLIFIED WIRING SYSTEM (SWS)
54B-242
STEP 12. Check the power window sub switch connector
E-05 and ETACS-ECU connector C-81 for damage.
Q:
YES : Go to Step 13.
NO : Repair or replace them. Refer to GROUP 00E,
Harness Connector Inspection
lock switch input signal should be able to be checked
and the central door locking system should work
normally.
AC003082 AJ
JUNCTION BLOCK
(FRONT VIEW)
CONNECTOR: C-81
AC003086 AN
DOOR
CONNECTOR: E-05