Mitsubishi Galant 9G. Manual — part 294
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-252
ACTUATOR TEST REFERENCE
M1554005200133
MUT-III SCAN TOOL
DISPLAY
ITEM NO.
INSPECTION ITEM
DRIVE CONTENT
Blower fan: OFF
01
Blower motor
OFF
Blower fan: 8 step
02
Middle speed
Blower fan: 16 step
03
High speed
Air mix damper motor:
0%
10
Air mixing damper control motor
Opening degree: approx.
0% (Max cool)
Air mix damper motor:
50%
11
Opening degree: approx.
50%
Air mix damper motor:
100%
12
Opening degree: approx.
100% (Max hot)
Air outlet c/o damper:
FACE
13
Mode selection damper control
motor
FACE
Air outlet c/o damper: Bi_
Level
14
FOOT/FACE
Air outlet c/o damper:
FOOT
15
FOOT
Air outlet c/o damper:
DEF/FOOT
16
DEF/FOOT
Air outlet c/o damper:
DEF
17
DEF
In/out changeover
damper: Recirc
30
Outside/inside air selection damper
control motor
Inside
In/out changeover
damper: Fresh
31
Outside
Rear defogger switch:
OFF
40
Rear window defogger switch
Rear window defogger: OFF
Rear defogger switch:
ON
41
Rear window defogger: ON
Idle up request: OFF
50
Idle up operation
Idle up: OFF
Idle up request: low load 51
Idle up: low load
Idle up request: high load 52
Idle up: high load
Condenser: 0%
09
Condenser fan
OFF
Condenser: 50%
0A
Middle speed
Condenser: 100%
0B
High speed
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-253
CHECK AT A/C-ECU TERMINAL <LOW TYPE>
M1552010300561
24
30
21
272829
2223
32
31
2526
AC306430
C-10
C-09
AB
TERMINAL
NO.
CHECK ITEM
CHECKING REQUIREMENTS NORMAL CONDITION
1
A/C pressure sensor ground
Always
0 V
2
Ground
Always
0 V
3
A/C pressure sensor
Ignition switch: ON
5 V
4
A/C pressure sensor
at 2.6 MPa
3.9 V
5, 6
−
−
−
7
Power supply to the ignition
switch (ACC)
Ignition switch: ON
Battery positive voltage
8
Back-up power supply
Always
Battery positive voltage
9
Air mixing damper control motor When the air mix damper is
moved to the MAX. COOL
position.
10 V
When the air mix damper is
moved to the MAX. HOT
position.
0.5 V
10
Sensors and potentiometers
ground
Always
0 V
11
Mode selection damper control
motor potentiometer input
When the damper has moved to
the DEF position.
0.67 V
12
Air mixing damper control motor
potentiometer input
When the damper door has
moved to the MAX. HOT
position.
1.4 V
13
Air thermo sensor input
When sensor temperature is
25
°C (77°F) [1.5 kΩ]
2.2 V
14
Ambient air temperature sensor
input
When sensor temperature is
25
°C (77°F) [4 kΩ]
1.9 V
15
Potentiometer power supply
Ignition switch: ON
5 V
16
Power supply to the ignition
switch (IG2)
Ignition switch: ON
Battery positive voltage
21
ILL power supply
Lighting switch: ON
Battery positive voltage
22
Illumination ground
Always
0 V
23
A/C compressor relay
A/C compressor relay: ON
Battery positive voltage
24
Blower switch
Ignition switch: ON
Blower switch: ON
Battery positive voltage
25, 26
−
−
−
27
Rear window defogger relay
Ignition switch: ON
Battery positive voltage
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-254
28
Outside/inside air selection
damper control motor (outside)
When the damper flap is
moving to the air recirculation
position.
0.5 V
When the damper flap is
moving to the outside air
position.
0 V (when the motor is
stopped)
29
Outside/inside air selection
damper control motor (inside)
When the damper flap is
moving to the air recirculation
position.
0 V (when the motor is
stopped)
When the damper flap is
moving to the outside air
position.
0.5 V
30
Mode selection damper control
motor (DEF)
When the damper is moved to
the FACE position.
0.5 V
When the damper is moved to
the DEF position.
10 V
31
Mode selection damper control
motor (FACE)
When the damper is moved to
the FACE position.
10 V
When the damper is moved to
the DEF position.
0.5 V
32
Air mixing damper control motor When the air mix damper is
moved to the MAX. COOL
position.
0.5 V
When the air mix damper is
moved to the MAX. HOT
position.
10 V
TERMINAL
NO.
CHECK ITEM
CHECKING REQUIREMENTS NORMAL CONDITION
MANUAL A/C DIAGNOSIS
TSB Revision
HEATER, AIR CONDITIONING AND VENTILATION
55A-255
CHECK AT A/C-ECU TERMINAL <MIDDLE TYPE>
M1552010300583
8
2
1
5
3 4
6 7
9 10
20
19
18
17
16
15
14
13
12
11
32
24
29
21
31
30
2223
27
35
33
25
34
26
36
28
AC210339
C-15
C-16
AB
TERMINAL
NO.
CHECK ITEM
CHECKING REQUIREMENTS NORMAL CONDITION
1
Air mixing damper control motor When the air mix damper is
moved to the MAX. COOL
position.
10 V
When the air mix damper is
moved to the MAX. HOT
position.
0.5 V
2
Air mixing damper control motor When the air mix damper is
moved to the MAX. COOL
position.
0.5 V
When the air mix damper is
moved to the MAX. HOT
position.
10 V
3
Back-up power supply
Always
Battery positive voltage
4
Mode selection damper control
motor (DEF)
When the damper is moved to
the FACE position.
0.5 V
When the damper is moved to
the DEF position.
10 V
5
Outside/inside air selection
damper control motor (outside)
When the damper flap is
moving to the air recirculation
position.
0.5 V
When the damper flap is
moving to the outside air
position.
0 V (when the motor is
stopped)
6
Outside/inside air selection
damper control motor (inside)
When the damper flap is
moving to the air recirculation
position.
0 V (when the motor is
stopped)
When the damper flap is
moving to the outside air
position.
0.5 V
7
−
−
−
8
Rear window defogger relay
Ignition switch: ON
Battery positive voltage
9
Blower relay
Ignition switch: ON
Battery positive voltage
10
A/C compressor relay
A/C compressor relay: ON
Battery positive voltage
11
Mode selection damper control
motor (FACE)
When the damper is moved to
the FACE position.
10 V
When the damper is moved to
the DEF position.
0.5 V