Mitsubishi L200. Manual — part 842
TROUBLESHOOTING
CONTROLLER AREA NETWORK (CAN)
54C-127
DIAGNOSIS PROCEDURE
STEP 1. Connector check: C-53 <LHD> or C-35
<RHD> intermediate connector, C-119 joint
connector (CAN1) and C-01 joint connector
(CAN2)
AC903853
BR
Connectors: C-01, C-53, C-119 <LHD>
C-01 (L)
C-53
C-119 (GR)
C-53
C-01, C-119
AC903865AW
Connectors: C-01, C-35 <RHD>
C-01 (L)
C-35
C-01
C-35
AC903868
CM
Connector: C-119 <RHD>
C-119 (GR)
CAUTION
The strand end of the twist wire should be within
10 cm from the connector. For details refer to
.
AC209350
1
12
2
13
3
14
4
15
5
16
6
17
7
18
8
19
9
20
10
21
11
22
AC209350
1
12
2
13
3
14
4
15
5
16
6
17
7
18
8
19
9
20
10
21
11
22
AC
Short pin
When checking the joint connector, ensure that its
wiring harness side and its short pins are not dam-
aged.
Q: Is the check result normal?
YES :
Go to Step 2.
NO :
Repair the defective connector. Replace the
joint connector as necessary.
STEP 2. Resistance measurement at C-119 joint
connector (CAN1) and C-53 <LHD> or C-35
<RHD> intermediate connector.
CAUTION
A digital multimeter should be used. For details
refer to
CAUTION
The test wiring harness should be used. For
details refer to
.
AC903853
BS
Connectors: C-53, C-119 <LHD>
C-53
C-119 (GR)
C-53
C-119
AC903865
Connector: C-35 <RHD>
AQ
AC903868
CM
Connector: C-119 <RHD>
C-119 (GR)
(1) Disconnect the joint connector (CAN1) and the
intermediate connector, and measure at the
wiring harness side.
(2) Turn the ignition switch to the LOCK (OFF)
TROUBLESHOOTING
CONTROLLER AREA NETWORK (CAN)
54C-128
position.
CAUTION
When measuring the resistance, disconnect the
negative battery terminal. For details refer to
.
(3) Ensure that the negative battery terminal is
disconnected.
AC204740
AC204740
AC204740
AC204740
AC204740
Female side: C-53 <LHD> or C-35 <RHD>
Harness side: C-119
NB
Test harness
Test
harness
(4) Continuity between C-119 joint connector (CAN1)
terminal No.11 and C-53 <LHD> or C-35 <RHD>
intermediate connector terminal No.6
OK: Continuity (2
Ω or less)
AC204740
AC204740
AC204740
Female side: C-53 <LHD> or C-35 <RHD>
Harness side: C-119
AC204740
AC204740
AC204740MU
Test harness
Test
harness
(5) Continuity between C-119 joint connector (CAN1)
terminal No.22 and C-53 <LHD> or C-35 <RHD>
intermediate connector terminal No.7
OK: Continuity (2
Ω or less)
CAUTION
Strictly observe the specified wiring harness
repair procedure. For details refer to
Q: Is the check result normal?
YES :
<All the resistances measure 2
Ω or less>
Go to Step 3 .
NO :
<Either or all of the resistances measure
more than 2
Ω> Repair the wiring harness
between joint connector (CAN1) and
intermediate connector C-53 <LHD> or C-
35 <RHD>.
TROUBLESHOOTING
CONTROLLER AREA NETWORK (CAN)
54C-129
STEP 3. Resistance measurement at C-01 joint
connector (CAN2) and C-53 <LHD> or C-35
<RHD> intermediate connector.
CAUTION
A digital multimeter should be used. For details
refer to
CAUTION
The test wiring harness should be used. For
details refer to
AC903853
BT
Connectors: C-01, C-53 <LHD>
C-01 (L)
C-53
C-53
C-01
AC903865AW
Connectors: C-01, C-35 <RHD>
C-01 (L)
C-35
C-01
C-35
(1) Disconnect joint connector (CAN2) and the
intermediate connector, and measure at the
wiring harness side.
(2) Turn the ignition switch to the LOCK (OFF)
position.
CAUTION
When measuring the resistance, disconnect the
negative battery terminal. For details refer to
.
(3) Ensure that the negative battery terminal is
disconnected.
AC204740
AC204740
AC204740
AC204740
AC204740
AC204740
Male side: C-53 <LHD> or C-35 <RHD>
Harness side: C-01
MV
Test harness
Test
harness
(4) Continuity between C-01 joint connector (CAN2)
terminal No.11 and C-53 <LHD> or C-35 <RHD>
intermediate connector terminal No.6
OK: Continuity (2
Ω or less)
AC204740
AC204740
AC204740
AC204740
Male side: C-53 <LHD> or C-35 <RHD>
Harness side: C-01
AC204740
AC204740
AC204740MW
Test harness
Test
harness
(5) Continuity between C-01 joint connector (CAN2)
terminal No.22 and C-53 <LHD> or C-35 <RHD>
TROUBLESHOOTING
CONTROLLER AREA NETWORK (CAN)
54C-130
intermediate connector terminal No.7
OK: Continuity (2
Ω or less)
CAUTION
Strictly observe the specified wiring harness
repair procedure. For details refer to
Q: Is the check result normal?
YES :
<All the resistances measure 2
Ω or less>
Follow diagnosis item 5, 6, 7, 8, 9, 10, 11,
13 and 14. Refer to
NO :
<Either or all of the resistances measure
more than 2
Ω> Repair the wiring harness
between the intermediate connector and the
intermediate connector.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.