Mitsubishi Evolution X. Manual — part 484
DOOR
TSB Revision
BODY
42A-39
STEP 6. Retest the system.
Check that the central door locking system works normally.
Q: Is the check result normal?
YES : No action is necessary and testing is complete.
NO : Replace the power window main switch. Check that
the central door locking system normally.
DOOR
TSB Revision
BODY
42A-40
INSPECTION PROCEDURE 3: Central Door Locking System does not Operate even when Door Lock
Switch of Front Power Window Sub Switch Operated (Door Lock Switch of Power Window Main
Switch Operate Normally).
AC709019
ETACS-ECU
FUSIBLE
LINK
37
DOOR
LOCK
RELAY
DRIVER'S
DOOR
UNLOCK
RELAY
PASSENGER'S
DOOR
UNLOCK
RELAY
RED
RED
FRONT DOOR LOCK ACTUATOR OR
REAR DOOR LOCK ACTUATOR
AB
Central Door Locking System Power Supply Circuit
POWER
WINDOW
MAIN
SWITCH
JOINT
CONNECTOR
(3)
JOINT
CONNECTOR
(1)
DOOR
LOCK
SWITCH
DOOR
LOCK
SWITCH
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW -RED
GRAY
GRAY
YELLOW -RED
YELLOW -RED
YELLOW -RED
GRAY
GRAY
GRAY
FRONT
POWER
WINDOW
SUB SWITCH
DOOR
TSB Revision
BODY
42A-41
.
CIRCUIT OPERATION
• The ETACS-ECU controls the central door lock
system, locking or unlocking all the doors by acti-
vating the central door lock relay (built into the
ETACS-ECU). The ETACS-ECU uses inputs from
the following components:
• Door lock actuator
• Door lock switch, which is incorporated in the
power window main switch or power window
sub switch
.
TROUBLESHOOTING HINTS
• The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
• The front power window sub switch may be
defective
DIAGNOSTIC PROCEDURE
STEP 1. Checking central door locking system operation
Check that the central door locking system works normally.
Q: Is the check result normal?
YES : Go to Step 2.
NO : Refer to Inspection procedure 1 "Central door locking
system does not work at all
."
STEP 2. Check front power window sub switch connector
E-08 for loose, corroded or damaged terminals, or
terminals pushed back in the connector.
Q: Is front power window sub switch connector E-08 in
good condition?
YES : Go to Step 3.
NO : Repair or check the connector. Refer to GROUP 00E,
Harness Connector Inspection
. Verify that all
the doors can be locked and unlocked normally.
AC708951AF
C-116
C-24
Connectors: C-24, C-116
AC708950AH
Connectors: C-101, C-103
C-103 (B)
C-101 (B)
AC608168 AI
Connector: E-08
DOOR
TSB Revision
BODY
42A-42
STEP 3. Check the front power window sub switch (door
lock switch).
Remove the front power window sub switch. Refer to
.
Q: Does the front power window sub switch work
normally?
YES : Go to Step 4.
NO : Replace the front power window sub switch. Verify
that all the doors can be locked and unlocked
normally.
STEP 4. Check the ground circuit to the front power
window sub switch. Measure the resistance at front power
window sub switch connector E-08.
(1) Disconnect front power window sub switch connector E-08
and measure the resistance available at the wiring harness
side of the connector.
(2) Measure the resistance value between terminal 4 and
ground.
• The resistance should be 2 ohms or less.
Q: Is the measured resistance 2 ohms or less?
YES : Go to Step 5.
NO : Go to Step 6.
Switch
position
Tester
connection
Specified
condition
LOCK
3
− 4
Continuity exists
(2
Ω or less)
UNLOCK
2
− 4
Continuity exists
(2
Ω or less)
AC609543
ZC600610
Door lock switch
AB
AC209731
Connector E-08
(Harness side)
AC208731BZ