Mitsubishi Outlander XL. Manual — part 729
CIRCUIT OPERATION
The ETACS-ECU operates the liftgate according to
signal from the liftgate lock release handle.
TECHNICAL DESCRIPTION (COMMENT)
If the signal is not normal, the liftgate will not work
normally. If the signal is not normal, the liftgate lock
release handle or the ETACS-ECU may be defective.
TROUBLESHOOTING HINTS
⦆
The liftgate lock release handle may be defective
⦆
The wiring harness or connectors may have loose,
corroded, or damaged terminals, or terminals
pushed back in the connector
⦆
The ETACS-ECU may be defective
DIAGNOSTIC PROCEDURE
Required Special Tools:
⦆
MB991223: Harness Set
⦆
MB992006: Extra Fine Probe
⦆
MB991958: Scan Tool (M.U.T.-III Sub Assembly)
⦆
MB991824: Vehicles Communication Interface (V.C.I.)
⦆
MB991827: M.U.T.-III USB Cable
⦆
MB991910: M.U.T.-III Main Harness A
STEP 1. Check liftgate lock release handle connector F-09
for loose, corroded or damaged terminals, or terminals
pushed back in the connector.
Q:Is liftgate lock release handle connector F-09 in good
condition?
YES:
Go to Step 2.
NO:
Repair or replace the damaged component(s). Refer to
GROUP 00E, Harness Connector Inspection P.00E-2. Repair
the liftgate lock release handle. If the liftgate lock
release handle operates normally, a correct signal is
sent from the liftgate lock release handle.
STEP 2. Check the liftgate lock release handle.
Remove the liftgate lock release handle. Refer to GROUP 42Ac,
Liftgate Handle and Latch P.42Ac-10. Then check continuity
between the switch terminals.
DOOR
42Ab-35
CENTRAL DOOR LOCKING SYSTEM DIAGNOSIS
ZC600117
Section A – A
0000
A
A
ON
OFF
<Vehicles without Keyless Operation System (KOS)>
Handle
position
Terminal
number
Normal value
ON
1 - 2
Continuity
exists (2 Ω or
less)
OFF
1 - 2
Open circuit
ZC6001180000
A
A
ON
OFF
Section A – A
Liftgate lock
release handle
Lock switch
Lock switch
<Vehicles with Keyless Operation System (KOS)>
Handle
position
Terminal
number
Normal value
ON
1 - 2
Continuity
exists (2 Ω or
less)
OFF
1 - 2
Open circuit
Q:Is the liftgate lock release handle in good condition?
YES:
Go to Step 3.
NO:
Repair the liftgate lock release handle. If the
liftgate lock release handle operates normally, a correct
signal is sent from the liftgate lock release handle.
STEP 3. Check the ground circuit to the liftgate lock release
handle. Measure the resistance at liftgate lock release
handle connector F-09.
(1)
Disconnect liftgate lock release handle connector F-09 and
measure the resistance on the wiring harness side of the
connector.
42Ab-36
DOOR
CENTRAL DOOR LOCKING SYSTEM DIAGNOSIS
ZC5007880002
Connector F-09
(harness side)
(2)
Measure the resistance value between terminal 2 and
ground.
⦆
The resistance should be 2 ohms or less.
Q:Is the measured resistance 2 ohms or less?
YES:
Go to Step 5.
NO:
Go to Step 4.
STEP 4. Check the wiring harness between liftgate lock
release handle connector F-09 (terminal 2) and ground.
Q:Is the wiring harness between liftgate lock release handle
connector F-09 (terminal 2) and ground in good
condition?
YES:
No action is necessary and testing is complete.
NO:
The wiring harness may be damaged or the connector
(s) may have loose, corroded or damaged terminals, or
terminals pushed back in the connector. Repair the wiring
harness as necessary. If the liftgate lock release handle
operates normally, a correct signal is sent from the
liftgate lock release handle.
STEP 5. Check ETACS-ECU connector C-313 for loose,
corroded or damaged terminals, or terminals pushed back
in the connector.
Q:Is ETACS-ECU connector C-313 in good condition?
YES:
Go to Step 6.
NO:
Repair or replace the damaged component(s). Refer to
GROUP 00E, Harness Connector Inspection P.00E-2. If the
liftgate lock release handle operates normally, a correct
signal is sent from the liftgate lock release handle.
STEP 6. Check the wiring harness between liftgate lock
release handle connector F-09 (terminal 1) and ETACS-ECU
connector C-313 (terminal 14).
NOTE:
Also check intermediate connector D-12 for loose,
corroded, or damaged terminals, or terminals pushed back in
the connector. If intermediate connector D-12 is damaged,
repair or replace the damaged component(s) as described in
GROUP 00E, Harness Connector Inspection P.00E-2.
Q:Is the wiring harness between liftgate lock release handle
connector F-09 (terminal 1) and ETACS-ECU connector
C-313 (terminal 14) in good condition?
YES:
Go to Step 7.
NO:
The wiring harness may be damaged or the connector
(s) may have loose, corroded or damaged terminals, or
terminals pushed back in the connector. Repair the wiring
harness as necessary. If the liftgate lock release handle
operates normally, a correct signal is sent from the
liftgate lock release handle.
DOOR
42Ab-37
CENTRAL DOOR LOCKING SYSTEM DIAGNOSIS
STEP 7. Using scan tool MB991958, check data list.
Check the signals related to the liftgate lock release handle
operation.
ZC501967
AC404789
ZC5019680000
MB991824
MB991827
MB991910
Data link
connector
To prevent damage to scan tool MB991958, always turn the
ignition switch to the "LOCK" (OFF) position before
connecting or disconnecting scan tool MB991958.
(1)
Connect scan tool MB991958. Refer to GROUP 54Ad, "How
to connect the Scan Tool (M.U.T.-III) P.54Ad-5."
(2)
Turn the ignition switch to the "ON" position.
(3)
Check the data list of the ETACS.
⦆
Liftgate lock release handle: from OFF to ON
Item No.
Item name
Normal
condition
230
Trunk / gate opener from OFF to
ON
(4)
Turn the ignition switch to the "LOCK" (OFF) position.
OK: Normal condition is displayed.
Q:Is the check result normal?
YES:
No action is necessary and testing is complete.
NO:
Replace the ETACS-ECU. If the liftgate lock release
handle operates normally, a correct signal is sent from
the liftgate lock release handle.
POWER WINDOW DIAGNOSIS
TROUBLESHOOTING STRATEGY
M14203000067USA0000010000
Refer to GROUP 00, How to Use Troubleshooting/Inspection
Service Points, Troubleshooting Contents P.00-6.
DIAGNOSTIC TROUBLE CODE CHART POWER WINDOW
M14203000069USA0000010000
On troubleshooting, if the ignition switch is turned
ON while disconnecting connector(s), diagnostic
trouble code(s) associated with other system may
be set. On completion, check all systems for
diagnostic trouble code(s). If diagnostic trouble
code(s) are set, erase them all.
Diagnostic trouble code
No.
Diagnostic item
Reference page
L0730
P/W (DR) SW pulse1 disconnection
L0732
P/W (DR) SW pulse2 disconnection
L0734
P/W (DR) Above window position
L0736
P/W (DR) Sensor fail (ground)
L0740
P/W (DR) 3 times jam - protection
L0746
P/W (DR) Parameter read fail
42Ab-38
DOOR
POWER WINDOW DIAGNOSIS
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст