Mitsubishi Outlander XL. Manual — part 1201
ZC600876
Connector: C-114
ZC600878000
Connector: C-303, C-309, C-315
C-303
C-309 (B)
C-315
TECHNICAL DESCRIPTION (COMMENT)
If the voltage is not supplied to the blower motor, the
blower relay system may be failed.
TROUBLESHOOTING HINTS
⦆
Malfunction of the ETACS-ECU
⦆
Malfunction of the blower relay
⦆
Damaged harness wires or connectors
DIAGNOSIS
Required Special Tools:
⦆
MB991223: Harness Set
⦆
MB992006: Extra Fine Probe
STEP 1. Check blower relay connector C-303 for loose,
corroded or damaged terminals, or terminals pushed back
in the connector.
Q:Is blower relay connector C-303 in good condition?
YES:
Go to Step 2.
NO:
Repair or replace the connector. Refer to GROUP 00E,
Harness Connector Inspection P.00E-2.
AIR CONDITIONING
55A-95
MANUAL A/C DIAGNOSIS
STEP 2. Check the blower relay continuity.
ZC603579
4
1
2
3
3
1
4
2
Blower relay
Follow the table below to check the blower relay for continuity.
Battery voltage
Connect
tester
between
Specified
condition
Not applied
3 - 4
Open Circuit
⦆
Connect terminal 1 to the
positive battery terminal
⦆
Connect terminal 2 to the
negative battery terminal
3 - 4 Less than 2 ohms
Q:Is the blower relay in good condition?
YES:
Go to Step 3.
NO:
Replace the rear window defogger relay.
STEP 3. Measure the voltage at blower relay connector
C-303.
(1)
Disconnect blower relay connector C-303, and measure the
voltage at the junction block side.
ZC6022230020
Harness side: C-303
(2)
Measure the voltage between terminals 1 and ground.
⦆
The measured value should be approximately 12 volts
(battery positive voltage).
(3)
Measure the voltage between terminals 4 and ground.
⦆
The measured value should be approximately 12 volts
(battery positive voltage).
Q:Is the measured voltage approximately 12 volts?
YES:
Go to Step 5.
NO:
Go to Step 4.
55A-96
AIR CONDITIONING
MANUAL A/C DIAGNOSIS
STEP 4. Check the wiring harness between blower relay
connector C-303 (terminals 1 and 4) and the fusible link (37).
Q:Is the wiring harness between blower relay connector
C-303 (terminals 1 and 4) and the fusible link (37) in good
condition?
YES:
It can be assumed that this malfunction is
intermittent. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points - How to Cope
with Intermittent Malfunctions P.00-15.
NO:
Repair or replace the wiring harness. Refer to GROUP
00E, Harness Connector Inspection P.00E-2.
STEP 5. Check blower relay connector C-114 for loose,
corroded or damaged terminals, or terminals pushed back
in the connector.
Q:Is blower relay connector C-114 in good condition?
YES:
Go to Step 6.
NO:
Repair or replace the connector. Refer to GROUP 00E,
Harness Connector Inspection P.00E-2.
STEP 6. Check the wiring harness between blower relay
connector C-303 (terminal 3) and blower motor connector
C-114 (terminal 2).
Q:Is the wiring harness between blower relay connector
C-303 (terminal 3) and blower motor connector C-114
(terminal 2) in good condition?
YES:
It can be assumed that this malfunction is
intermittent. Refer to GROUP 00, How to Use
Troubleshooting/Inspection Service Points - How to Cope
with Intermittent Malfunctions P.00-15.
NO:
Repair or replace the wiring harness. Refer to GROUP
00E, Harness Connector Inspection P.00E-2.
DATA LIST REFERENCE TABLE
M15502000100USA0000010000
Refer to GROUP 55B - Data list reference table P.
55B-13.)
ACTUATOR TEST REFERENCE
M15502000101USA0000010000
Refer to GROUP 55B - Actuator test reference P.
55B-18.)
CHECK AT A/C-ECU TERMINAL
M15502000103USA0000010000
32
24
29
21
31
30
22 23
27
35
33
25
34
26
36
28
ZC603629
<C-109>
<C-108>
AIR CONDITIONING
55A-97
MANUAL A/C DIAGNOSIS
Terminal
No.
Check items
Check conditions
Normal conditions
1
Power transistor (DRAIN)
Air volume control dial: Maximum air
volume
0 to 2 V
2
Power transistor (GATE)
Air volume control dial: Maximum air
volume
Battery voltage
3 - 8
-
-
-
9
A/C control panel (input)
-
-
10
A/C control panel (input)
-
-
11, 12
-
-
-
13
Battery power supply
Always
Battery voltage
14
Ground
Always
0 V
15
IG1 power supply
Ignition switch: IG1
Battery voltage
16
A/C pressure sensor input
17
Interior temperature sensor
Sensor probe temperature: 25°C
(77°F) (4.0 kΩ)
2.1 to 2.7 V
18
-
-
-
19
Sensor ground
Always
0 V
20
A/C pressure sensor power
supply
Ignition switch: IG2
5 V
21
Air thermo sensor ground
Always
0 V
22
Air thermo sensor
Sensor probe temperature: 25°C
(77°F) (4.0 kΩ)
2.1 to 2.7 V
23
-
-
-
24
Motor for air outside/inside
air
circulation
switching
damper
-
-
25
Motor for air outside/inside
air
circulation
switching
damper
-
-
26
Motor for air outside/inside
air
circulation
switching
damper
-
-
27
Motor for air outside/inside
air
circulation
switching
damper
-
-
28
Air mix damper motor
-
-
29
Motor power supply
-
-
30
Air
outlet
changeover
damper motor
-
-
31
Air
outlet
changeover
damper motor
-
-
32
Air
outlet
changeover
damper motor
-
-
55A-98
AIR CONDITIONING
MANUAL A/C DIAGNOSIS